Wyoming's low-voltage television technician exam (ICC 237): 30 questions on CATV and antenna systems, grounding and bonding, and coaxial cables outside and inside buildings (Articles 810 and 820). Open book, 70% to pass.

Questions
30
Time limit
90 min
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Cable TV Systems

A CATV line amplifier is to be powered through the coaxial cable. What is the highest voltage Article 820 allows on that coaxial cable?

Requirements at a glance

AgencyWyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE
Exam30 questions, 1 hour 30 minutes, 70% to pass
Experience4,000 hours over at least 2 years.
Books allowedNEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index
Fees$115 per exam to Pearson VUE; the license is $100 for 3 years.

Technicians applying to the Wyoming State Fire Marshal for a low-voltage television technician license. You need 4,000 hours of experience over at least 2 years.

How to get licensed, step by step

  1. Check your experience

    Make sure you meet the State Fire Marshal's requirements for the low-voltage television technician license: 4,000 hours over at least 2 years.

    Wyoming State Fire Marshal: electrical licensing (opens in a new tab)

  2. Apply and get approved

    Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.

    Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)

  3. Register and pay with Pearson VUE

    Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.

    Register with ICC at Pearson VUE (opens in a new tab)

  4. Pass the exam

    Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.

    Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)

How to prepare

  • ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
  • Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
  • Protection, grounding and bonding is the biggest area, 8 of the 30 questions. Know the grounding rules in Articles 800, 810 and 820.
  • Cables outside and entering buildings (7) and within buildings (6) are mostly Article 820 coaxial cable; antennas (Article 810) are 5.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential

    Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.

    NFPA store (opens in a new tab)Free online access (opens in a new tab)

  • Ugly's Electrical References (any edition)

    Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.

    Jones & Bartlett (opens in a new tab)

  • Ferm's Fast Finder Index or Tom Henry's Key Word Index

    Both are allowed, and a good index saves time on the questions you must look up.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
  • Ugly's Electrical References (any edition)
  • Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index

What's on the exam

Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):

TopicQuestions
General Cable TV Systems4
TV Antennas, Transmitters, and Receivers5
TV and Antenna System Protection and Grounding and Bonding8
Cables and Conductors Outside and Entering Buildings7
Cables and Conductors Within Buildings6

Exam day details

  • Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
  • Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
  • 30 questions in 1 hour 30 minutes; 70% to pass (041-5 Wyo. Code R. § 3).
  • Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
  • Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
  • Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
  • You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
  • ICC exam number 237. "TV and Antenna System Protection and Grounding and Bonding" is 8 of the 30 questions, so weight your study there.

Frequently asked questions

What's on the Wyoming low-voltage television technician exam?

ICC's August 2025 outline, 30 questions: General Cable TV Systems 4; TV Antennas, Transmitters, and Receivers 5; TV and Antenna System Protection and Grounding and Bonding 8; Cables and Conductors Outside and Entering Buildings 7; Cables and Conductors Within Buildings 6.

Which NEC edition do I bring to the Wyoming electrical exam?

ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.

Who gives the Wyoming electrical exams?

ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.

Free questions with answers

Show all 10 free questions and answers
  1. A CATV line amplifier is to be powered through the coaxial cable. What is the highest voltage Article 820 allows on that coaxial cable?

    Answer: 60 volts

    Section 820.15 permits coaxial cable to carry power to equipment directly associated with the RF distribution system when the voltage is not over 60 volts and the current is supplied by a transformer or other power-limiting device. Higher voltage falls under Article 830 methods.

    Reference: NFPA 70, National Electrical Code, 2023, 820.15

  2. A receiving-station lead-in is a coaxial cable. Under what condition does Section 810.20(A) not require an antenna discharge unit on the lead-in?

    Answer: The lead-in is enclosed in a continuous metallic shield that is grounded

    Section 810.20(A) requires each lead-in conductor from an outdoor antenna to have a listed antenna discharge unit, with an exception where the lead-in is enclosed in a continuous metallic shield that is grounded as required by 810.21. Length, mounting height or plenum rating does not qualify.

    Reference: NFPA 70, National Electrical Code, 2023, 810.20(A)

  3. A CATV coaxial cable enters a house from an outdoor drop. Where must the outer conductive shield be grounded under Article 820?

    Answer: As close as practicable to the point where the cable enters

    Section 820.93(A) requires the outer conductive shield of entering coaxial cable to be grounded in accordance with 820.100, as close as practicable to the point of entrance. Grounding far inside the building lengthens the bonding conductor and weakens lightning protection.

    Reference: NFPA 70, National Electrical Code, 2023, 820.93(A)

  4. The bonding conductor from a CATV ground block must be able to carry at least as much current as which part of the circuit?

    Answer: The outer conductive shield of the coaxial cable

    Section 820.100(A) requires the bonding conductor or grounding electrode conductor to have a current-carrying capacity at least equal to that of the coaxial cable's outer conductive shield, and not smaller than 14 AWG. It need not be larger than 6 AWG.

    Reference: NFPA 70, National Electrical Code, 2023, 820.100(A)(3)

  5. A CATV aerial cable is to be attached to a utility pole that also carries electric supply conductors. How must the cable be placed?

    Answer: Below the power conductors, and not on a crossarm that carries power

    Section 800.44(A), in the general Chapter 8 rules that Article 820 applies to coaxial cable, requires aerial cable on poles to be located below the electric light and power conductors where practicable, and not attached to a crossarm that carries them. Cable type (CATVP or otherwise) does not change the rule.

    Reference: NFPA 70, National Electrical Code, 2023, 800.44(A)

  6. A CATV coaxial cable is direct buried in the same trench as unprotected 120/240 volt power conductors with no raceway or metal armor. What minimum separation applies?

    Answer: 300 mm (12 in.)

    Section 800.47(B), the general Chapter 8 underground rule that covers coaxial cable, requires direct-buried cable to be separated by at least 300 mm (12 in.) from conductors of light, power, Class 1 and non-power-limited fire alarm circuits unless the power conductors are in a raceway or have metal cable armor. The 50 mm (2 in.) figure is the in-building separation in 800.133(B).

    Reference: NFPA 70, National Electrical Code, 2023, 800.47(B)

  7. Unlisted outside plant coaxial cable enters a building and ends at a grounded primary protector. How far inside may it extend from the point of entrance if it is not in a metal raceway?

    Answer: 15 m (50 ft)

    Section 800.48, the general Chapter 8 rule that covers coaxial cable, permits unlisted outside plant cable in building spaces other than risers, plenums and other air-handling spaces for up to 15 m (50 ft) from the point of entrance, provided it terminates at a grounding block or primary protector. Beyond that, listed CATV cable is required unless the run is in rigid or intermediate metal conduit.

    Reference: NFPA 70, National Electrical Code, 2023, 800.48

  8. A CATV contractor must run coaxial cable in a hung ceiling that serves as a return-air plenum, without a raceway. Which type may be installed there?

    Answer: CATVP plenum cable

    Section 820.113 allows only plenum-listed coaxial cable (CATVP) exposed in other spaces used for environmental air under 300.22(C). Riser and general-purpose types may be used there only in a suitable raceway, such as EMT.

    Reference: NFPA 70, National Electrical Code, 2023, 820.113

  9. A job calls for Type CATVR riser coaxial cable, but only other listed types are available. According to the coaxial cable substitution table in Article 820, which type may replace it?

    Answer: CATVP

    A higher-rated cable may replace a lower-rated one, so plenum-listed CATVP may replace CATVR. CATV and CATVX are lower-rated types, and unlisted cable is not an allowed substitute inside a building.

    Reference: NFPA 70, National Electrical Code, 2023, 820.154, Cable Substitutions table

  10. Conductors from a transmitting antenna enter a building. Which method does Article 810 accept for the entrance?

    Answer: Through a rigid, noncombustible, nonabsorbent insulating tube or bushing

    Section 810.55 requires transmitting-station lead-in conductors (unless enclosed in a grounded continuous metallic shield) to enter the building through a rigid, noncombustible, nonabsorbent insulating tube or bushing, through an opening made for the purpose in which the conductors are firmly secured with at least 50 mm (2 in.) clearance, or through a drilled window pane. A bare opening or conductors resting on wood do not satisfy the rule.

    Reference: NFPA 70, National Electrical Code, 2023, 810.55