Requirements at a glance
| Agency | Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE |
|---|---|
| Exam | 50 questions, 3 hours, 70% to pass |
| Experience | 4,000 hours (about 2 years) in that portion of the industry. |
| Books allowed | NEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index |
| Fees | $115 per exam to Pearson VUE; the license is $100 for 3 years. |
Technicians applying to the Wyoming State Fire Marshal for a low-voltage technician license. You need 4,000 hours of experience in that part of the industry.
Official links
- Wyoming State Fire Marshal: electrical licensing (opens in a new tab)
- Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)
- Register with ICC at Pearson VUE (opens in a new tab)
- ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)
- 041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
How to get licensed, step by step
Check your experience
Make sure you meet the State Fire Marshal's requirements for the low-voltage technician license: 4,000 hours (about 2 years) in that portion of the industry.
Wyoming State Fire Marshal: electrical licensing (opens in a new tab)
Apply and get approved
Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.
Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)
Register and pay with Pearson VUE
Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.
Pass the exam
Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.
Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
How to prepare
- ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
- Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
- Communication and sound systems are 18 of the 50 questions. Know Chapter 8 (Article 800 and related communications articles), Article 640 and Article 725.
- Remote control and alarm systems (11) lean on Article 725 and Article 760. Fiber optical cables (Article 770) is only 2 questions.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential
Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Ugly's Electrical References (any edition)
Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.
Ferm's Fast Finder Index or Tom Henry's Key Word Index
Both are allowed, and a good index saves time on the questions you must look up.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
- Ugly's Electrical References (any edition)
- Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index
What's on the exam
Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge | 12 | |
| Low-voltage Remote Control and Alarm Systems | 11 | |
| Low-voltage Communication and Sound Systems | 18 | |
| Low-voltage Control Circuits | 7 | |
| Fiber Optical Cables and Raceways | 2 |
Exam day details
- Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
- Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
- 50 questions in 3 hours; 70% to pass (041-5 Wyo. Code R. § 3).
- Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
- Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
- Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
- You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
- ICC exam number 218. Communication and sound systems are 36% of the exam, so weight your study there.
Frequently asked questions
What's on the Wyoming low-voltage general technician exam?
ICC's August 2025 outline, 50 questions: communication and sound systems 36% (18), general knowledge 24% (12), remote control and alarm systems 22% (11), control circuits 14% (7) and fiber optical cables and raceways 4% (2).
Which NEC edition do I bring to the Wyoming electrical exam?
ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.
Who gives the Wyoming electrical exams?
ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.
Free questions with answers
Show all 10 free questions and answers
According to the purpose statement in Article 90, what is the NEC intended to accomplish?
Answer: Practical safeguarding of persons and property from hazards arising from the use of electricity
90.1(A) states that the Code is for the practical safeguarding of persons and property from hazards arising from the use of electricity. 90.1(B) adds that it is not a design specification or an instruction manual for untrained persons. Training hours and rates are set by other bodies.
Reference: NFPA 70, National Electrical Code, 2023, 90.1(A)
Which wording in the NEC identifies a permissive rule, meaning an action that is allowed but not required?
Answer: "Shall be permitted" or "shall not be required"
90.5 explains that "shall" and "shall not" mark mandatory rules, while "shall be permitted" and "shall not be required" mark permissive rules. Informational Notes are explanatory and are not enforceable requirements.
Reference: NFPA 70, National Electrical Code, 2023, 90.5(A) and (B)
How must the circuit disconnecting means (breaker) for a branch circuit that supplies a fire alarm control panel be identified?
Answer: Red identification, marked "FIRE ALARM CIRCUIT"
760.41(B) requires the fire alarm branch-circuit disconnecting means to have red identification, to be accessible only to qualified persons and to be identified as "FIRE ALARM CIRCUIT". The same wording appears in 760.121(B) for power-limited fire alarm power sources.
Reference: NFPA 70, National Electrical Code, 2023, 760.41(B)
An electrician plans to supply a power-limited fire alarm power supply from an existing circuit that also feeds lobby receptacles. Under 760.121(B), this is:
Answer: Not permitted, because the circuit may supply no other loads
760.121(B) requires the branch circuit that supplies fire alarm equipment to supply no other loads. A shared circuit could be shut off by unrelated switching or tripped by an unrelated fault. GFCI or a larger breaker does not change the rule.
Reference: NFPA 70, National Electrical Code, 2023, 760.121(B)
Unshielded Cat 6 cable will run along a wall surface next to open 120-volt power conductors that are not in a raceway or metal-sheathed cable. What minimum separation does Article 800 require between the communications cable and the power conductors?
Answer: 50 mm (2 in.)
800.133 requires communications wires and cables to be separated at least 50 mm (2 in.) from electric light, power, Class 1 and non-power-limited fire alarm conductors. The separation is not required if the power conductors are in a raceway or in metal-sheathed, metal-clad, nonmetallic-sheathed or Type UF cable.
Reference: NFPA 70, National Electrical Code, 2023, 800.133
A pathway puts a Class 2 thermostat pair and a data cable in one listed communications cable. Which statement about mixing circuits in the same cable is correct?
Answer: Class 2 and Class 3 conductors may share the cable; Class 1 may not
800.133 prohibits Class 1 circuits in the same cable with communications circuits, while Class 2 and Class 3 circuit conductors are permitted in the same listed communications cable. Conductor size and low voltage do not remove the Class 1 prohibition.
Reference: NFPA 70, National Electrical Code, 2023, 800.133
In a one-family dwelling, a telephone primary protector is mounted at the building exterior. How long may the conductor from the protector to the grounding electrode system generally be?
Answer: As short as practicable, up to 6.0 m (20 ft)
800.100 requires the bonding conductor or grounding electrode conductor to be as short as practicable and, in one- and two-family dwellings, not longer than 6.0 m (20 ft). If that cannot be met, a separate ground rod bonded to the power electrode system is used. A larger wire does not remove the length limit.
Reference: NFPA 70, National Electrical Code, 2023, 800.100(A)
A Class 1 power-limited circuit is supplied by a power source other than a transformer, rated 90 VA at 12 V. Using 167 percent of the source's rated current, what is the maximum rating of its overcurrent device?
Answer: 12.5 A
Rated current = 90 VA / 12 V = 7.5 A. Maximum overcurrent device = 7.5 x 1.67 = 12.525, about 12.5 A. 7.5 A skips the 167 percent factor, 4.5 A divides by 1.67 instead of multiplying, and 25 A uses 334 percent (double the factor).
Reference: NFPA 70, National Electrical Code, 2023, 724.40(A)(2)
Class 2 conductors enter a control enclosure only to connect the equipment that the Class 2 circuit serves. The 120-volt conductors in the enclosure are routed to stay apart from them. What separation does 725.136(D) call for?
Answer: 6 mm (1/4 in.)
725.136(D) allows Class 2 and Class 3 conductors in an enclosure with power conductors when they are introduced solely to connect equipment connected to the Class 2 circuit and the power conductors are routed to maintain at least 6 mm (1/4 in.) separation. The 50 mm figure applies to open wiring outside enclosures.
Reference: NFPA 70, National Electrical Code, 2023, 725.136(D)
An optical fiber cable contains a metallic armor and a metallic strength member but no current-carrying conductors. How is it classified?
Answer: Conductive optical fiber cable
Article 100 defines a conductive optical fiber cable as one containing non-current-carrying conductive members such as metallic strength members, vapor barriers or armor. A nonconductive cable has none, and a composite cable also contains current-carrying electrical conductors.
Reference: NFPA 70, National Electrical Code, 2023, Article 100, Optical Fiber Cable, Conductive
Sources
- ICC: Wyoming Electrical Contractor/Trades Bulletin (8/2025, PDF) (opens in a new tab)
- Wyoming State Fire Marshal: Electrical licensing (opens in a new tab)
- 041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
Questions last verified October 29, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.