Wyoming licensing exam

Wyoming Journeyman Electrician Exam: Practice Test & Licensing Guide

Wyoming's journeyman electrician exam (ICC 385): 80 questions on the NEC, led by wiring methods, branch circuits and services. Open book, 70% to pass.

Questions
80
Time limit
4 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge

A 240-volt resistance heating element has a resistance of 12 ohms. What current does it draw when energized?

Requirements at a glance

AgencyWyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE
Exam80 questions, 4 hours, 70% to pass
Experience8,000 hours (about 4 years) plus 576 hours of approved classroom training, with no more than 75% in any one category.
Books allowedNEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index
Fees$115 per exam to Pearson VUE; the license is $100 for 3 years.

Electricians applying to the Wyoming State Fire Marshal for a journeyman electrician license. You need 8,000 hours of experience plus 576 hours of approved classroom training.

How to get licensed, step by step

  1. Check your experience

    Make sure you meet the State Fire Marshal's requirements for the journeyman electrician license: 8,000 hours (about 4 years) plus 576 hours of approved classroom training, with no more than 75% in any one category.

    Wyoming State Fire Marshal: electrical licensing (opens in a new tab)

  2. Apply and get approved

    Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.

    Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)

  3. Register and pay with Pearson VUE

    Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.

    Register with ICC at Pearson VUE (opens in a new tab)

  4. Pass the exam

    Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.

    Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)

How to prepare

  • ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
  • Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
  • Wiring methods and materials (21) and branch circuits and conductors (15) are 36 of the 80 questions: spend your tab budget on Chapters 2 and 3.
  • Motors, generators and control devices are only 8 questions together, so learn the Article 430 basics and move on.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential

    Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.

    NFPA store (opens in a new tab)Free online access (opens in a new tab)

  • Ugly's Electrical References (any edition)

    Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.

    Jones & Bartlett (opens in a new tab)

  • Ferm's Fast Finder Index or Tom Henry's Key Word Index

    Both are allowed, and a good index saves time on the questions you must look up.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
  • Ugly's Electrical References (any edition)
  • Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index

What's on the exam

Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):

TopicQuestions
General Knowledge5
Services and Service Equipment9
Feeders3
Branch Circuits and Conductors15
Wiring Methods and Materials21
Equipment and Devices10
Control Devices3
Motors and Generators5
Special Occupancies, Equipment, and Conditions9

Exam day details

  • Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
  • Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
  • 80 questions in 4 hours; 70% to pass (041-5 Wyo. Code R. § 3).
  • Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
  • Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
  • Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
  • You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
  • ICC exam number 385. Wiring methods and materials (21) and branch circuits and conductors (15) are almost half the exam.

Frequently asked questions

What's on the Wyoming journeyman electrician exam?

ICC's August 2025 outline, 80 questions: wiring methods and materials 21, branch circuits and conductors 15, equipment and devices 10, services and service equipment 9, special occupancies, equipment and conditions 9, general knowledge 5, motors and generators 5, feeders 3 and control devices 3.

Which NEC edition do I bring to the Wyoming electrical exam?

ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.

Who gives the Wyoming electrical exams?

ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.

Free questions with answers

Show all 10 free questions and answers
  1. A 240-volt resistance heating element has a resistance of 12 ohms. What current does it draw when energized?

    Answer: 20 A

    By Ohm's law, I = E / R = 240 / 12 = 20 A. Multiplying (240 x 12 = 2,880) is a common slip, and 2.0 A or 28.8 A come from misplacing the decimal or using a wrong formula; only direct division gives the current.

    Reference: General electrical theory, Ohm's law: I = E / R

  2. A 75-kVA, 3-phase, 208Y/120-volt transformer has 3 percent impedance. Assuming an infinite source, what is the approximate available 3-phase fault current at the transformer secondary terminals?

    Answer: 6,940 A

    Secondary FLA = 75,000 / (1.732 x 208) = 208.2 A. Available fault current = FLA / impedance = 208.2 / 0.03 = 6,940 A. 208 A is the full-load current alone, 12,020 A multiplies by 1.732 instead, and 3,470 A assumes 6 percent impedance.

    Reference: General electrical theory, Available fault current from transformer impedance

  3. Field-installed feeder tap conductors not over 10 feet long are run from a 400-ampere feeder under the 10-foot tap rule, and they leave the enclosure where the tap is made. What is the minimum ampacity the tap conductors must have, based on the feeder overcurrent device rating?

    Answer: 40 A, which is one-tenth of 400 A

    Section 240.21(B)(1) says that where field-installed tap conductors leave the enclosure in which the tap is made, their ampacity must be at least one-tenth of the rating of the overcurrent device protecting the feeder: 400 x 0.10 = 40 A. They must also be no smaller than the computed load and the rating of the device they terminate in. One-third applies to the 25-foot tap rule, and the other fractions are not in the section.

    Reference: NFPA 70, National Electrical Code, 2023, Section 240.21(B)(1)

  4. How many 20-ampere small-appliance branch circuits are required at a minimum to serve the kitchen, pantry and dining room receptacle outlets of a dwelling unit?

    Answer: Two

    Section 210.11(C)(1) requires at least two 20-ampere small-appliance branch circuits for the receptacle outlets in the kitchen, pantry, breakfast and dining areas. These circuits are separate from the laundry and bathroom circuits.

    Reference: NFPA 70, National Electrical Code, 2023, Section 210.11(C)(1)

  5. In a dwelling unit, along the floor line of a habitable room wall, no point may be more than what distance, measured horizontally, from a receptacle outlet?

    Answer: 6 feet

    Section 210.52(A) requires receptacles so that no point along the floor line of any usable wall space is more than 6 ft from an outlet, which results in a maximum 12-ft spacing between outlets. 12 ft is the spacing between outlets, not the distance to the nearest one.

    Reference: NFPA 70, National Electrical Code, 2023, Section 210.52(A)(1)

  6. A 480Y/277-volt panelboard has grounded concrete wall on the opposite side of the working space from exposed live parts (condition 2). What is the minimum depth of working space in front of the panelboard?

    Answer: 3.5 feet

    Table 110.26(A)(1) lists 3.5 ft for 151 to 600 volts to ground under condition 2, with 3 ft for condition 1 and 4 ft for condition 3. 3 ft applies if no grounded or live parts face the equipment.

    Reference: NFPA 70, National Electrical Code, 2023, Table 110.26(A)(1)

  7. A non-IC-rated recessed luminaire is installed in an insulated ceiling. How far must thermal insulation be kept from the luminaire?

    Answer: At least 3 inches from the luminaire housing and not above it

    Section 410.116 requires thermal insulation to stay at least 3 in from the enclosure, wiring compartment or ballast of a non-IC luminaire, and not be placed above it where heat could build up. An IC-rated luminaire is the type that may be covered by insulation.

    Reference: NFPA 70, National Electrical Code, 2023, Section 410.116

  8. Under the motor-controller rules, which device may serve as the controller for a portable motor rated 1/3 horsepower or less?

    Answer: A cord with an attachment plug and receptacle

    Section 430.81(B) permits an attachment plug and receptacle to serve as the controller for a portable motor of 1/3 hp or less. A fuse alone does not control starting and stopping, and a transformer is not a motor controller.

    Reference: NFPA 70, National Electrical Code, 2023, Section 430.81(B)

  9. A 3-phase, 208-volt motor is rated 10 hp. Using the motor full-load current table, what is the minimum ampacity of the branch-circuit conductors for a single continuous-duty motor?

    Answer: 38.5 A

    Table 430.250 gives 30.8 A for a 10 hp, 208-V, 3-phase motor. Section 430.22 requires 125 percent: 30.8 x 1.25 = 38.5 A. 30.8 A omits the factor, and 46.2 A applies 150 percent.

    Reference: NFPA 70, National Electrical Code, 2023, Section 430.22 and Table 430.250

  10. At a permanently installed residential swimming pool, where must the required 125-volt, 15- or 20-ampere receptacle be located relative to the inside walls of the pool?

    Answer: At least 6 feet and not more than 20 feet from the inside wall

    Section 680.22(A) requires at least one 125-volt receptacle on a general-purpose branch circuit located a minimum of 6 ft and a maximum of 20 ft from the inside wall of the pool. Receptacles closer than 6 ft are not permitted except where specifically allowed.

    Reference: NFPA 70, National Electrical Code, 2023, 680.22(A)(1)