Wyoming licensing exam

Wyoming Limited HVAC Technician Exam: Practice Test & Licensing Guide

Wyoming's limited hvac technician exam (ICC 600): 40 questions on HVAC equipment and motors, control circuits, wiring methods and grounding. Open book, 70% to pass.

Questions
40
Time limit
2 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Knowledge, Theory, Basic Load Calculations, and Definitions

A 240-volt electric heating element has a resistance of 12 ohms. How much current does it draw?

Requirements at a glance

AgencyWyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE
Exam40 questions, 2 hours, 70% to pass
Experience4,000 hours over at least 2 years.
Books allowedNEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index
Fees$115 per exam to Pearson VUE; the license is $100 for 3 years.

Technicians applying to the Wyoming State Fire Marshal for a limited hvac technician license. You need 4,000 hours of experience over at least 2 years.

How to get licensed, step by step

  1. Check your experience

    Make sure you meet the State Fire Marshal's requirements for the limited HVAC technician license: 4,000 hours over at least 2 years.

    Wyoming State Fire Marshal: electrical licensing (opens in a new tab)

  2. Apply and get approved

    Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.

    Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)

  3. Register and pay with Pearson VUE

    Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.

    Register with ICC at Pearson VUE (opens in a new tab)

  4. Pass the exam

    Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.

    Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)

How to prepare

  • ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
  • Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
  • HVAC equipment and motors are 15 of the 40 questions. Know Articles 440, 430, 424 and 422 and where the nameplate and disconnect rules sit.
  • Control circuits including thermostat wiring (Article 725) are 5 questions; grounding, wiring methods and feeders and branch circuits are 5 each.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential

    Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.

    NFPA store (opens in a new tab)Free online access (opens in a new tab)

  • Ugly's Electrical References (any edition)

    Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.

    Jones & Bartlett (opens in a new tab)

  • Ferm's Fast Finder Index or Tom Henry's Key Word Index

    Both are allowed, and a good index saves time on the questions you must look up.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
  • Ugly's Electrical References (any edition)
  • Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index

What's on the exam

Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):

TopicQuestions
General Knowledge, Theory, Basic Load Calculations, and Definitions5
Feeders, Branch Circuits, and Conductors5
Wiring Methods (Load Side of Disconnect to Equipment or Motor)5
Control Circuits (Includes Thermostat Wires)5
Equipment Grounding and Bonding5
HVAC Equipment and Motors (Load Side of Disconnect to Equipment or Motor)15

Exam day details

  • Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
  • Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
  • 40 questions in 2 hours; 70% to pass (041-5 Wyo. Code R. § 3).
  • Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
  • Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
  • Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
  • You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
  • ICC exam number 600. "HVAC Equipment and Motors (Load Side of Disconnect to Equipment or Motor)" is 15 of the 40 questions, so weight your study there.

Frequently asked questions

What's on the Wyoming limited hvac technician exam?

ICC's August 2025 outline, 40 questions: General Knowledge, Theory, Basic Load Calculations, and Definitions 5; Feeders, Branch Circuits, and Conductors 5; Wiring Methods (Load Side of Disconnect to Equipment or Motor) 5; Control Circuits (Includes Thermostat Wires) 5; Equipment Grounding and Bonding 5; HVAC Equipment and Motors (Load Side of Disconnect to Equipment or Motor) 15.

Which NEC edition do I bring to the Wyoming electrical exam?

ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.

Who gives the Wyoming electrical exams?

ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.

Free questions with answers

Show all 10 free questions and answers
  1. A 240-volt electric heating element has a resistance of 12 ohms. How much current does it draw?

    Answer: 20 A

    Ohm's law: I = E / R = 240 / 12 = 20 A. Using 120 V gives 10 A, using 480 V gives 40 A, and R / E = 12 / 240 = 0.05 A is the inverted formula.

    Reference: General electrical theory: Ohm's law, Ohm's law (I = E / R)

  2. A three-phase, 208-volt air handler draws 24 A per phase. What is its apparent power, in volt-amperes?

    Answer: 8,646 VA

    Three-phase VA = 1.732 x E x I = 1.732 x 208 x 24 = 8,646 VA. 208 x 24 = 4,992 VA omits the 1.732 factor; 240 x 24 = 5,760 VA uses the wrong voltage; 3 x 208 x 24 = 14,976 VA uses 3 instead of the square root of 3.

    Reference: General electrical theory: three-phase power, Three-phase power (VA = 1.732 x E x I)

  3. A feeder to a rooftop unit carries a 40-A continuous load and a 20-A noncontinuous load. What is the minimum feeder conductor ampacity before correction or adjustment?

    Answer: 70 A

    Feeder conductors must carry 125 percent of the continuous load plus 100 percent of the noncontinuous load: (40 x 1.25) + 20 = 70 A. Simply adding the loads gives 60 A, which skips the 125 percent factor. 75 A applies the factor to the entire 60-A total, and 80 A doubles the continuous load instead of applying 125 percent.

    Reference: NFPA 70, National Electrical Code, 2023, Article 215 (feeder ampacity for continuous loads)

  4. A mechanical room runs at 40 C. A 10 AWG THWN-2 conductor rated 40 A at 90 C passes through it, and the correction factor for that ambient is 0.91. What is the conductor's corrected ampacity?

    Answer: 36.4 A

    Corrected ampacity = 40 A x 0.91 = 36.4 A. 40 A ignores the correction, 44 A divides by the factor instead of multiplying, and 32 A applies a 0.80 conductor-count adjustment that does not apply here. The 75 C termination limit of 35 A would still govern the circuit load.

    Reference: NFPA 70, National Electrical Code, 2023, Table 310.16 and the ambient temperature correction factors (310.15(B))

  5. Liquidtight flexible metal conduit (LFMC) is used for the final connection to a condensing unit. Where the run is not fished, what is the maximum spacing between supports?

    Answer: 4-1/2 ft, and within 12 in of each box or fitting

    LFMC must be secured at intervals not exceeding 4-1/2 ft and within 12 in of each box, cabinet or fitting, with exceptions for short flexible lengths. The 10 ft / 3 ft figures belong to EMT and 6 ft is not an LFMC support spacing.

    Reference: NFPA 70, National Electrical Code, 2023, Article 350 (350.30, securing and supporting)

  6. A 40-A circuit terminates at a packaged HVAC unit. The unit's terminals have no temperature marking. Which Table 310.16 column must be used to size the conductors for that circuit?

    Answer: 60 C

    For circuits rated 100 A or less (or 14 through 1 AWG), terminations without a marked temperature rating are treated as 60 C, so conductors are sized from the 60 C column. Equipment listed for 75 C could use the 75 C column. A 90 C conductor may be used only to start the derating calculation, never to set the terminal limit.

    Reference: NFPA 70, National Electrical Code, 2023, 110.14(C)(1)(a) (temperature limitations at terminations)

  7. A 24-volt Class 2 thermostat cable is to be pulled into a conduit that also carries the 120-volt power conductors for a furnace. Which statement is correct?

    Answer: It is not permitted unless a permanent barrier separates the two circuits

    Class 2 and Class 3 circuits may not share a raceway or enclosure with light, power or Class 1 conductors unless separated by a barrier, with limited exceptions (such as conductors entering solely to connect to the same equipment inside the enclosure). A voltage rating, conductor size or metal conduit alone does not remove the separation requirement.

    Reference: NFPA 70, National Electrical Code, 2023, 725.136(A) and (B) (separation from power and Class 1 conductors)

  8. Which fastener is NOT permitted to connect an equipment grounding conductor to a metal enclosure?

    Answer: A sheet-metal screw

    Equipment grounding conductors must be connected by listed means, such as pressure connectors, machine screws that engage at least two threads or a nut, or listed grounding lugs. Sheet-metal screws are not permitted for this purpose.

    Reference: NFPA 70, National Electrical Code, 2023, 250.8(A) (permitted methods) and 250.8(B) (sheet-metal screws not permitted)

  9. The nameplate of a 240-volt, single-phase air conditioner shows a minimum circuit ampacity (MCA) of 27 A. Using 75 C terminations, what is the smallest copper branch-circuit conductor?

    Answer: 10 AWG

    Conductors are sized to at least the nameplate MCA. Table 310.16, 75 C column: 12 AWG = 25 A (less than 27 A) and 10 AWG = 35 A. 14 AWG is only 20 A, and 8 AWG (50 A) is larger than required.

    Reference: NFPA 70, National Electrical Code, 2023, 440.4(B) and Table 310.16

  10. Where must the disconnecting means for an outdoor air-conditioning condenser be located?

    Answer: Within sight from the equipment and readily accessible

    The disconnect must be in sight from the air-conditioning equipment (visible and not more than 50 ft away) and readily accessible. A lockable-open disconnect in other locations is allowed only where specific exceptions apply, not simply because it is labeled.

    Reference: NFPA 70, National Electrical Code, 2023, 440.14 (location of disconnecting means)

Sources

Questions last verified October 29, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.