Requirements at a glance
| Agency | Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE |
|---|---|
| Exam | 30 questions, 1 hour 30 minutes, 70% to pass |
| Experience | 4,000 hours over at least 2 years. |
| Books allowed | NEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index |
| Fees | $115 per exam to Pearson VUE; the license is $100 for 3 years. |
Technicians applying to the Wyoming State Fire Marshal for a low-voltage sound technician license. You need 4,000 hours of experience over at least 2 years.
Official links
- Wyoming State Fire Marshal: electrical licensing (opens in a new tab)
- Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)
- Register with ICC at Pearson VUE (opens in a new tab)
- ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)
- 041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
How to get licensed, step by step
Check your experience
Make sure you meet the State Fire Marshal's requirements for the low-voltage sound technician license: 4,000 hours over at least 2 years.
Wyoming State Fire Marshal: electrical licensing (opens in a new tab)
Apply and get approved
Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.
Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)
Register and pay with Pearson VUE
Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.
Pass the exam
Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.
Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
How to prepare
- ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
- Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
- General sound systems (9) and permanent and portable audio (4) are both Article 640: tab it well.
- Class 1, 2 and 3 circuits (Articles 722 to 725) are 7 questions; grounding and sensitive electronic equipment (Article 647) are 5 each.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential
Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Ugly's Electrical References (any edition)
Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.
Ferm's Fast Finder Index or Tom Henry's Key Word Index
Both are allowed, and a good index saves time on the questions you must look up.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
- Ugly's Electrical References (any edition)
- Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index
What's on the exam
Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Sound Systems | 9 | |
| Grounding | 5 | |
| Permanent and Portable Audio Systems | 4 | |
| Sensitive Electronic Equipment | 5 | |
| Class 1, Class 2, and Class 3 Circuits | 7 |
Exam day details
- Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
- Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
- 30 questions in 1 hour 30 minutes; 70% to pass (041-5 Wyo. Code R. § 3).
- Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
- Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
- Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
- You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
- ICC exam number 236. "General Sound Systems" is 9 of the 30 questions, so weight your study there.
Frequently asked questions
What's on the Wyoming low-voltage sound technician exam?
ICC's August 2025 outline, 30 questions: General Sound Systems 9; Grounding 5; Permanent and Portable Audio Systems 4; Sensitive Electronic Equipment 5; Class 1, Class 2, and Class 3 Circuits 7.
Which NEC edition do I bring to the Wyoming electrical exam?
ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.
Who gives the Wyoming electrical exams?
ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.
Free questions with answers
Show all 10 free questions and answers
Bundles of speaker and microphone cable are piled above a suspended ceiling so thickly that the ceiling tiles below an amplifier junction point can no longer be lifted out. Under 640.5, is this acceptable?
Answer: No, an accumulation of wires and cables may not prevent removal of panels, including suspended ceiling panels
640.5 says access to electrical equipment shall not be denied by an accumulation of wires and cables that prevents removal of panels, including suspended ceiling panels. Low power, tagging and conduit do not change that; the cables must be arranged so the panels can be removed.
Reference: NFPA 70, National Electrical Code, 2023, 640.5
A powered (amplified) loudspeaker plugged into a 120-volt branch-circuit receptacle is to be set near an outdoor swimming pool. Under 640.10(A), what is the minimum lateral distance from the inside wall of the pool?
Answer: 5 ft
640.10(A): audio equipment supplied by branch-circuit power shall not be placed laterally within 5 ft (1.5 m) of the inside wall of a pool, spa, hot tub or fountain, or the prevailing or tidal high-water mark, and is GFCI protected where other articles require. 640.10(B) covers equipment powered by listed Class 2 supplies.
Reference: NFPA 70, National Electrical Code, 2023, 640.10(A)
How is a receptacle that has an insulated (isolated) grounding terminal for a recording rack identified?
Answer: By an orange triangle on the face of the receptacle
406.3 requires a receptacle with an insulated (isolated) grounding terminal to be identified by an orange triangle located on the face of the receptacle. Using it correctly also means running an insulated equipment grounding conductor to it as 250.146(D) describes. Red stripes, GFCI lettering and blue faces are not the code identification.
Reference: NFPA 70, National Electrical Code, 2023, 406.3 (isolated ground receptacles)
A sound technician cannot cure a hum in a studio rack and proposes breaking off the grounding pin of an amplifier's three-prong plug. What does the NEC say about this fix?
Answer: It is not permitted, because the equipment grounding path must stay intact and the hum must be cured by other means
Cord-and-plug-connected equipment is grounded through the equipment grounding conductor in its cord and the plug's grounding pin (250.138(A)). 250.6 allows alterations to stop objectionable current only where the required grounding paths are kept, and 250.6(D) states that currents causing noise or data errors in electronic equipment are not objectionable currents under that section, so hum is never a reason to remove the ground.
Reference: NFPA 70, National Electrical Code, 2023, 250.138(A); 250.6
For a permanent sound system in a theater lobby, an installer wants to run a flexible cord from the rack through a hole in the wall to a receptacle in the next room. What does the NEC say about using a flexible cord this way?
Answer: Not permitted, because flexible cords may not be used as a substitute for fixed wiring or be run through holes in walls
400.12 prohibits flexible cords and cables from being used as a substitute for fixed wiring of a structure and from being run through holes in walls, ceilings or floors. A bushing or heavy-duty cord does not change that. A permanent installation needs a permanent wiring method.
Reference: NFPA 70, National Electrical Code, 2023, 400.12
In a 120-volt, single-phase, 3-wire system installed under Article 647, what is the voltage from each ungrounded conductor to the grounded center-tap conductor?
Answer: 60 volts
Article 647 allows a separately derived system with 60 volts on each of two ungrounded conductors to the grounded center tap, so the line-to-line voltage is 60 + 60 = 120 volts. Neither 240 nor 120 volts appears from line to ground in this arrangement.
Reference: NFPA 70, National Electrical Code, 2023, 647.3
A mixing-console relay panel needs a Class 1 power-limited remote-control circuit. The proposed source is a 24-volt, 1,200 volt-ampere transformer. Does this meet the Class 1 power-limited source limits in 724.40?
Answer: No, because the source may not exceed 1,000 volt-amperes
724.40 limits a Class 1 power-limited source to 30 volts and 1,000 volt-amperes. The 24-volt voltage is fine, but 1,200 VA exceeds the limit, so the circuit would have to be a Class 1 remote-control circuit wired with the full Class 1 rules instead.
Reference: NFPA 70, National Electrical Code, 2023, 724.40
Which of the following is an acceptable power source for a Class 2 intercom circuit under 725.60(A)?
Answer: A listed Class 2 transformer
725.60(A) permits a Class 2 circuit to be supplied by a listed Class 2 transformer or power supply (or other listed equipment marked as a Class 2 source). An unlisted or unmarked transformer, a plain branch circuit, or a Class 1 source does not provide the required power limitation.
Reference: NFPA 70, National Electrical Code, 2023, 725.60(A)
After a studio renovation, abandoned Class 2 speaker cable remains in an accessible ceiling space. It is not tagged for future use. What does 722.25 require?
Answer: The accessible portion of the abandoned cable must be removed
722.25 requires the accessible portion of abandoned Class 2, Class 3 and other power-limited cables to be removed unless it is tagged for future use. Low voltage does not exempt it, and the 100-ft cutoff is invented. Taping the ends does not satisfy the rule.
Reference: NFPA 70, National Electrical Code, 2023, 722.25
Under the Article 100 definition, which supply is a separately derived system for an Article 647 installation?
Answer: An isolation transformer whose secondary has no direct tie to the primary conductors
Article 100 defines a separately derived system as a source of power (other than a service) with no direct connection from its circuit conductors to the conductors of another system, apart from grounding and bonding connections. An isolation transformer qualifies; an autotransformer shares conductors with the primary, and a branch circuit or service tap is not a derived source.
Reference: NFPA 70, National Electrical Code, 2023, Article 100, Separately Derived System
Sources
- ICC: Wyoming Electrical Contractor/Trades Bulletin (8/2025, PDF) (opens in a new tab)
- Wyoming State Fire Marshal: Electrical licensing (opens in a new tab)
- 041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
Questions last verified October 29, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.