Question 1 of 10General Knowledge of Electricity and Code Definitions

A 24-volt irrigation controller transformer supplies a master valve (0.3 A), a zone valve (0.3 A) and a pump-start relay (0.15 A) at the same time. What is the total load on the transformer in volt-amperes?

Requirements at a glance

AgencyWyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE
Exam30 questions, 1 hour 30 minutes, 70% to pass
Experience4,000 hours over at least 2 years.
Books allowedNEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index
Fees$115 per exam to Pearson VUE; the license is $100 for 3 years.

Technicians applying to the Wyoming State Fire Marshal for a low-voltage lawn sprinkler and landscape lighting technician license. You need 4,000 hours of experience over at least 2 years.

How to get licensed, step by step

  1. Check your experience

    Make sure you meet the State Fire Marshal's requirements for the low-voltage lawn sprinkler and landscape lighting technician license: 4,000 hours over at least 2 years.

    Wyoming State Fire Marshal: electrical licensing (opens in a new tab)

  2. Apply and get approved

    Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.

    Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)

  3. Register and pay with Pearson VUE

    Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.

    Register with ICC at Pearson VUE (opens in a new tab)

  4. Pass the exam

    Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.

    Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)

How to prepare

  • ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
  • Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
  • General electrical knowledge and code definitions are 12 of the 30 questions: Ohm's law, Article 100 and the basics in Ugly's.
  • Wiring methods for circuits under 90 volts (10) means Article 411 landscape lighting and Class 2 wiring; Class 2 and 3 circuits are 6 and transformers 2.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential

    Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.

    NFPA store (opens in a new tab)Free online access (opens in a new tab)

  • Ugly's Electrical References (any edition)

    Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.

    Jones & Bartlett (opens in a new tab)

  • Ferm's Fast Finder Index or Tom Henry's Key Word Index

    Both are allowed, and a good index saves time on the questions you must look up.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
  • Ugly's Electrical References (any edition)
  • Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index

What's on the exam

Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):

TopicQuestions
General Knowledge of Electricity and Code Definitions12
Wiring Methods for Circuits Operating at Less Than 90 Volts10
Circuits and Conductors for Class 2 and Class 3 Circuits6
Low-voltage Transformers2

Exam day details

  • Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
  • Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
  • 30 questions in 1 hour 30 minutes; 70% to pass (041-5 Wyo. Code R. § 3).
  • Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
  • Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
  • Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
  • You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
  • ICC exam number 253. "General Knowledge of Electricity and Code Definitions" is 12 of the 30 questions, so weight your study there.

Frequently asked questions

What's on the Wyoming low-voltage lawn sprinkler and landscape lighting technician exam?

ICC's August 2025 outline, 30 questions: General Knowledge of Electricity and Code Definitions 12; Wiring Methods for Circuits Operating at Less Than 90 Volts 10; Circuits and Conductors for Class 2 and Class 3 Circuits 6; Low-voltage Transformers 2.

Which NEC edition do I bring to the Wyoming electrical exam?

ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.

Who gives the Wyoming electrical exams?

ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.

Free questions with answers

Show all 10 free questions and answers
  1. A 24-volt irrigation controller transformer supplies a master valve (0.3 A), a zone valve (0.3 A) and a pump-start relay (0.15 A) at the same time. What is the total load on the transformer in volt-amperes?

    Answer: 18 VA

    The devices are in parallel, so currents add: 0.3 + 0.3 + 0.15 = 0.75 A. Load = E x I = 24 V x 0.75 A = 18 VA. Dividing 24 by 0.75 inverts the formula, and 0.75 is the current, not the volt-ampere load.

    Reference: General electrical theory, General electrical theory: parallel circuits and VA = E x I

  2. A 24-volt zone valve solenoid draws 0.3 A. It is 400 ft (one way) from the controller on 14 AWG solid uncoated copper, which has 3.07 ohms per 1,000 ft (Chapter 9, Table 8). What is the voltage drop on the pair of wires?

    Answer: 0.74 V

    The current travels out and back, so the length is 2 x 400 = 800 ft. Resistance = 3.07 ohms x 0.8 = 2.456 ohms. Voltage drop = I x R = 0.3 A x 2.456 ohms = 0.74 V. Using one-way length halves it, 2.46 is the resistance in ohms, and 0.92 ignores the length.

    Reference: NFPA 70, National Electrical Code, 2023, Chapter 9, Table 8

  3. A 24-volt sprinkler valve control circuit for a lawn is run in Type UF cable, buried in the lawn away from driveways and roads. Using Table 300.5, what is the minimum cover?

    Answer: 6 in. (150 mm)

    Table 300.5 has a column for circuits that control irrigation and landscape lighting, limited to not more than 30 volts and installed with Type UF or other identified cable or raceway; its cover in a lawn is 6 in. The 12-in. figure is for 120-volt residential branch circuits with GFCI protection, 18 in. for listed nonmetallic raceways and 24 in. for ordinary direct-buried cable.

    Reference: NFPA 70, National Electrical Code, 2023, Table 300.5

  4. Type UF cable carries a 120-volt, 20-ampere residential branch circuit with GFCI protection from a garage to a transformer post in the yard. Using Table 300.5, what is the minimum cover for the direct-buried cable in the lawn?

    Answer: 12 in. (300 mm)

    Table 300.5 gives 12 in. for residential branch circuits rated 120 volts or less with GFCI protection and a maximum overcurrent device of 20 A. The 6-in. cover is only for 30-volt-or-less irrigation and landscape lighting control circuits, and 24 in. is for direct-buried cable without the GFCI condition.

    Reference: NFPA 70, National Electrical Code, 2023, Table 300.5

  5. A 120-volt, 20-ampere circuit has no GFCI protection ahead of it and runs in direct-buried Type UF cable under an open lawn to a pump house. Using Table 300.5, what is the minimum cover?

    Answer: 24 in. (600 mm)

    Without the GFCI condition the 12-in. column does not apply, and direct-buried cable falls in the general 24-in. column of Table 300.5 for all locations not otherwise listed. The 6-in. figure is for low-voltage irrigation and landscape lighting control circuits only.

    Reference: NFPA 70, National Electrical Code, 2023, Table 300.5

  6. A 24-volt ac transformer will power a Class 2 sprinkler control circuit. Using Chapter 9, Table 11(A), what is the maximum volt-ampere rating of this Class 2 power source?

    Answer: 100 VA

    Chapter 9, Table 11(A) limits an ac Class 2 source operating between 20 and 30 volts to 100 VA. 1,000 VA is the Class 1 power-limited limit of 724.40, not a Class 2 limit.

    Reference: NFPA 70, National Electrical Code, 2023, Chapter 9, Table 11(A)

  7. Which of the following is an acceptable power source for a Class 2 sprinkler control circuit under 725.60(A)?

    Answer: A listed Class 2 transformer or power supply

    725.60(A) permits a Class 2 circuit to be supplied by a listed Class 2 transformer or power supply (or other listed equipment marked as a Class 2 source). An unlisted or unmarked transformer, a plain branch circuit, or a Class 1 source does not provide the required power limitation.

    Reference: NFPA 70, National Electrical Code, 2023, 725.60(A)

  8. A sprinkler controller is moved, and the old 24-volt Class 2 cable remains in an accessible garage ceiling. It is not tagged for future use. What does 722.25 require?

    Answer: The accessible portion of the abandoned cable must be removed

    722.25 requires the accessible portion of abandoned Class 2 and Class 3 cable to be removed unless it is tagged for future use. Low voltage does not exempt it, and the 100-ft cutoff is invented. Taping the ends does not satisfy the rule.

    Reference: NFPA 70, National Electrical Code, 2023, 722.25

  9. According to the notes to Chapter 9, Tables 11(A) and 11(B), what must be durably marked, where plainly visible, on a listed Class 2 power supply?

    Answer: The class of supply and its electrical rating

    The notes to Chapter 9, Tables 11(A) and 11(B) require a Class 2 or Class 3 power source to be durably marked where plainly visible to show the class of supply and its electrical rating. This lets an installer see at once that it is a power-limited source and what it can supply.

    Reference: NFPA 70, National Electrical Code, 2023, Chapter 9, Tables 11(A) and 11(B), Notes

  10. A 12-volt landscape transformer is rated 300 W (VA) at full load. How many 35-watt, 12-volt fixtures can be connected without exceeding the rating?

    Answer: 8 fixtures

    The maximum number of fixtures is 300 W / 35 W = 8.57, rounded down to 8 (8 x 35 = 280 W). A ninth fixture would make the load 315 W, over the rating. Twenty-five is the full-load current in amperes (300 / 12), not a fixture count.

    Reference: General electrical theory, General electrical theory: power and transformer loading

Sources

Questions last verified October 29, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.