Wyoming licensing exam

Wyoming Low-voltage Control Technician Exam: Practice Test & Licensing Guide

Wyoming's low-voltage control technician exam (ICC 238): 30 questions on Class 1, 2 and 3 circuits, instrumentation tray cable, optical fiber, fire alarm and communications control wiring. Open book, 70% to pass.

Questions
30
Time limit
90 min
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10General Low-voltage Control

In Article 100, what kind of circuit is a remote-control circuit?

Requirements at a glance

AgencyWyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE
Exam30 questions, 1 hour 30 minutes, 70% to pass
Experience4,000 hours over at least 2 years.
Books allowedNEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index
Fees$115 per exam to Pearson VUE; the license is $100 for 3 years.

Technicians applying to the Wyoming State Fire Marshal for a low-voltage control technician license. You need 4,000 hours of experience over at least 2 years.

How to get licensed, step by step

  1. Check your experience

    Make sure you meet the State Fire Marshal's requirements for the low-voltage control technician license: 4,000 hours over at least 2 years.

    Wyoming State Fire Marshal: electrical licensing (opens in a new tab)

  2. Apply and get approved

    Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.

    Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)

  3. Register and pay with Pearson VUE

    Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.

    Register with ICC at Pearson VUE (opens in a new tab)

  4. Pass the exam

    Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.

    Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)

How to prepare

  • ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
  • Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
  • Class 1, 2 and 3 circuits (9) and instrumentation tray cable, optical fiber and power distribution systems (9) are 18 of the 30 questions.
  • Know Articles 722 to 727, 770 and 720 (circuits under 50 volts), plus where Article 480 storage batteries and Article 760 fire alarm controls sit.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential

    Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.

    NFPA store (opens in a new tab)Free online access (opens in a new tab)

  • Ugly's Electrical References (any edition)

    Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.

    Jones & Bartlett (opens in a new tab)

  • Ferm's Fast Finder Index or Tom Henry's Key Word Index

    Both are allowed, and a good index saves time on the questions you must look up.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
  • Ugly's Electrical References (any edition)
  • Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index

What's on the exam

Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):

TopicQuestions
General Low-voltage Control3
Circuits and Equipment Operating at Less than 50 Volts and Storage Batteries3
Class 1, Class 2, and Class 3 Circuits9
Fire Alarm System Controls Circuit3
Instrumentation Tray Cable, Optical Fiber Cables, Closed Loop and Programmed Power Distribution9
Communication System Control Wiring3

Exam day details

  • Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
  • Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
  • 30 questions in 1 hour 30 minutes; 70% to pass (041-5 Wyo. Code R. § 3).
  • Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
  • Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
  • Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
  • You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
  • ICC exam number 238. "Class 1, Class 2, and Class 3 Circuits" is 9 of the 30 questions, so weight your study there.

Frequently asked questions

What's on the Wyoming low-voltage control technician exam?

ICC's August 2025 outline, 30 questions: General Low-voltage Control 3; Circuits and Equipment Operating at Less than 50 Volts and Storage Batteries 3; Class 1, Class 2, and Class 3 Circuits 9; Fire Alarm System Controls Circuit 3; Instrumentation Tray Cable, Optical Fiber Cables, Closed Loop and Programmed Power Distribution 9; Communication System Control Wiring 3.

Which NEC edition do I bring to the Wyoming electrical exam?

ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.

Who gives the Wyoming electrical exams?

ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.

Free questions with answers

Show all 10 free questions and answers
  1. In Article 100, what kind of circuit is a remote-control circuit?

    Answer: Controls another circuit through a relay or equivalent device

    Article 100 defines a remote-control circuit as any electrical circuit that controls any other circuit through a relay or an equivalent device. A circuit that energizes an alarm horn or buzzer is a signaling circuit, and the load-current path of a motor is part of the branch circuit.

    Reference: NFPA 70, National Electrical Code, 2023, Article 100, Remote-Control Circuit

  2. A relay coil in a 24-volt control circuit draws 0.25 A. What is the resistance of the coil?

    Answer: 96 ohms

    Using Ohm's law, R = E / I = 24 V / 0.25 A = 96 ohms. The wrong answers come from multiplying (24 x 0.25 = 6 ohms), using 0.5 A (48 ohms) or using 0.125 A (192 ohms).

    Reference: NFPA 70, National Electrical Code, 2023, General electrical theory: Ohm's law

  3. A 24-volt ac low-voltage control system is powered by a transformer fed from a 277/480-volt, three-phase, four-wire system. Does 250.20(A) require this 24-volt system to be grounded?

    Answer: Yes, because the supply system exceeds 150 volts to ground

    Section 250.20(A) requires ac systems of less than 50 volts to be grounded where they are supplied by transformers whose primary supply system exceeds 150 volts to ground. A 277/480 V system has 277 V to ground. The low voltage and the Class 2 classification do not remove this requirement, and location is not the test.

    Reference: NFPA 70, National Electrical Code, 2023, 250.20(A)

  4. A 24-volt ac control system inside a building is fed from a transformer whose primary is supplied from a grounded 120/208-volt, three-phase, four-wire system. No conductors run overhead outside the building. Under 250.20(A), is the 24-volt system required to be grounded?

    Answer: No, because the supply is 120 volts to ground and no conductors run overhead outdoors

    The grounding requirement for systems under 50 volts applies only if the supply system exceeds 150 volts to ground, the supply system is ungrounded, or the conductors are run overhead outside buildings. A 120/208 V system has 120 V to ground, which is under 150 V, so none of these conditions apply. The 208 V line-to-line value is not the test.

    Reference: NFPA 70, National Electrical Code, 2023, 250.20(A)

  5. What are the maximum source ratings for a Class 1 power-limited circuit?

    Answer: 30 volts and 1,000 volt-amperes

    A Class 1 power-limited circuit must be supplied from a source rated at not more than 30 volts and 1,000 volt-amperes. 600 volts is the limit for a Class 1 remote-control or signaling circuit, which has no power limit, and 100 VA is a Class 2 style limit. See 724.40.

    Reference: NFPA 70, National Electrical Code, 2023, 724.40

  6. What is the maximum overcurrent protection allowed for 16 AWG conductors of a Class 1 circuit?

    Answer: 10 amperes

    Section 724.43 limits overcurrent protection to 7 amperes for 18 AWG and 10 amperes for 16 AWG Class 1 conductors. 7 A is the 18 AWG limit, and 15 A and 20 A are the ratings for 14 AWG and 12 AWG branch-circuit wiring.

    Reference: NFPA 70, National Electrical Code, 2023, 724.43

  7. A relay circuit that releases magnetic door holders and shuts down air-handler fans when the fire alarm system activates is powered and controlled by the fire alarm system. Which article covers its wiring?

    Answer: Article 760, since it is a circuit controlled and powered by the fire alarm system

    Section 760.1 includes in Article 760 the circuits controlled and powered by the fire alarm system, which covers auxiliary control circuits such as door holders and fan shutdown relays. The motors themselves are still covered by the motor rules, but the fire alarm control wiring follows Article 760.

    Reference: NFPA 70, National Electrical Code, 2023, 760.1

  8. Communications cable that controls a remote alarm dialer will be run exposed in a hung ceiling that is a return-air plenum. Which cable type may be installed without a raceway?

    Answer: Type CMP plenum-rated cable

    Section 800.113 and its table allow only plenum-rated communications cable (Type CMP), or cable in a suitable metal raceway, in a plenum. CMR, CM and CMX types do not have the plenum fire and smoke rating.

    Reference: NFPA 70, National Electrical Code, 2023, 800.113

  9. Type ITC (instrumentation tray cable) may be installed in cable trays under what condition?

    Answer: In industrial establishments where only qualified persons service the installation

    Article 727 allows Type ITC cable in cable trays, raceways and similar supported runs in industrial establishments where maintenance and supervision ensure that only qualified persons service the installation. It is not a general-purpose cable for dwellings, and it is not limited to outdoors or to a 600-volt rating.

    Reference: NFPA 70, National Electrical Code, 2023, 727.4

  10. Optical fiber cable is run exposed, without a raceway, between floors in a vertical shaft. Which nonconductive cable type is the minimum rating for this use?

    Answer: Type OFNR

    Riser use calls for Type OFNR (nonconductive riser), or the higher-rated plenum type OFNP as a substitute. OFNG and OFN are general-purpose types without the vertical flame rating, and OFCG is a conductive general-purpose type, which is not rated for riser use either. See 770.113 and Table 770.154(a).

    Reference: NFPA 70, National Electrical Code, 2023, 770.113

Sources

Questions last verified October 29, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.