Requirements at a glance
| Agency | Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE |
|---|---|
| Exam | 30 questions, 1 hour 30 minutes, 70% to pass |
| Experience | 4,000 hours over at least 2 years. |
| Books allowed | NEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index |
| Fees | $115 per exam to Pearson VUE; the license is $100 for 3 years. |
Technicians applying to the Wyoming State Fire Marshal for a low-voltage communications technician license. You need 4,000 hours of experience over at least 2 years.
Official links
- Wyoming State Fire Marshal: electrical licensing (opens in a new tab)
- Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)
- Register with ICC at Pearson VUE (opens in a new tab)
- ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)
- 041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
How to get licensed, step by step
Check your experience
Make sure you meet the State Fire Marshal's requirements for the low-voltage communications technician license: 4,000 hours over at least 2 years.
Wyoming State Fire Marshal: electrical licensing (opens in a new tab)
Apply and get approved
Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.
Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)
Register and pay with Pearson VUE
Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.
Pass the exam
Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.
Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
How to prepare
- ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
- Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
- Communications wires and cables outside and entering buildings (6) and within buildings (6) are 12 of the 30 questions. Know Article 800 and Article 805.
- Protection and grounding (5), optical fiber (Article 770, 5) and computer and broadband systems (Articles 645 and 830, 3) round it out.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential
Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Ugly's Electrical References (any edition)
Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.
Ferm's Fast Finder Index or Tom Henry's Key Word Index
Both are allowed, and a good index saves time on the questions you must look up.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
- Ugly's Electrical References (any edition)
- Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index
What's on the exam
Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Communication Systems | 5 | |
| Communication Wires/Cables Outside and Entering Buildings | 6 | |
| Communication Wires/Cables Within Buildings | 6 | |
| Telecommunication System Protection and Grounding and Bonding | 5 | |
| Optical Fiber Cables and Raceways | 5 | |
| Computer Systems and Broadband Communications | 3 |
Exam day details
- Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
- Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
- 30 questions in 1 hour 30 minutes; 70% to pass (041-5 Wyo. Code R. § 3).
- Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
- Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
- Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
- You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
- ICC exam number 233. "Communication Wires/Cables Outside and Entering Buildings" is 6 of the 30 questions, so weight your study there.
Frequently asked questions
What's on the Wyoming low-voltage communications technician exam?
ICC's August 2025 outline, 30 questions: General Communication Systems 5; Communication Wires/Cables Outside and Entering Buildings 6; Communication Wires/Cables Within Buildings 6; Telecommunication System Protection and Grounding and Bonding 5; Optical Fiber Cables and Raceways 5; Computer Systems and Broadband Communications 3.
Which NEC edition do I bring to the Wyoming electrical exam?
ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.
Who gives the Wyoming electrical exams?
ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.
Free questions with answers
Show all 10 free questions and answers
A technician wants the NEC rules that apply in common to telephone, data and similar communications circuits in a building. Which article holds those general requirements?
Answer: Article 800
Article 800 gives the general requirements for communications systems, and the specific communications articles build on it. Article 725 covers Class 2 and Class 3 circuits, Article 760 covers fire alarm systems, and Article 640 covers audio equipment.
Reference: NFPA 70, National Electrical Code, 2023, 800.1
How do the Chapter 8 communications rules relate to the general wiring rules in Chapters 1 through 7 of the NEC?
Answer: Chapter 8 stands on its own and is not subject to Chapters 1 through 7 unless Chapter 8 specifically references them
Section 90.3 explains that Chapter 8 is independent of Chapters 1 through 7 except where Chapter 8 specifically refers to a rule there, such as the 300.22 plenum references. This is why a communications installer reads Article 800 first rather than the general wiring chapters.
Reference: NFPA 70, National Electrical Code, 2023, 90.3
A telephone cable is direct buried in the same trench as 120/240 volt feeder conductors that are not in a raceway and have no metal armor. What minimum separation must be kept between the telephone cable and the feeder?
Answer: 300 mm (12 in.)
Section 800.47 requires direct-buried communications cable to be separated by at least 300 mm (12 in.) from light and power conductors that are not in a raceway or metal armor. The 50 mm (2 in.) figure is the above-ground separation in 800.133, and the 600 mm value is not an Article 800 distance.
Reference: NFPA 70, National Electrical Code, 2023, 800.47
Where practicable, what separation must be kept between communications wires and cables on a building and lightning conductors?
Answer: 1.8 m (6 ft)
Section 800.53 calls for a separation of at least 1.8 m (6 ft) between communications wires and cables on buildings and lightning conductors where practicable. This limits side-flash risk during a strike.
Reference: NFPA 70, National Electrical Code, 2023, 800.53
Communications cable will run exposed between floors of a three-story apartment building through a vertical shaft that is not fireproof, with no raceway. What is the minimum listed type?
Answer: Type CMR riser cable
Table 800.113 lists CMR as the riser type for vertical runs through floors. CMP also qualifies because it has a higher rating, but CMG, CMX and CMUC are lower-rated types and are not permitted in an unprotected riser run.
Reference: NFPA 70, National Electrical Code, 2023, Table 800.113
A job calls for Type CMR communications cable, but only other listed types are on the truck. According to the cable substitution table in Article 800, which type may be used in its place?
Answer: Type CMP
Table 805.154 lists the permitted communications cable substitutions: a cable with a higher fire rating may replace a lower one. CMP, the plenum type, may replace CMR. CMG, CMX and CMUC have lower ratings than CMR and are not permitted substitutes.
Reference: NFPA 70, National Electrical Code, 2023, Table 805.154
A communications primary protector is bonded to the building grounding system. What is the largest size the bonding conductor or grounding electrode conductor is required to be under Section 800.100(A)?
Answer: 6 AWG
The conductor may be no smaller than 14 AWG, must carry at least as much current as the protected cable's metal members, and is not required to be larger than 6 AWG. A larger size is not wrong, but the code never requires it, so 6 AWG is the upper limit of what can be required.
Reference: NFPA 70, National Electrical Code, 2023, 800.100(A)(3)
A one-family dwelling's telephone primary protector is mounted so that the run to the nearest electrode would be 25 ft. What does Section 800.100(A)(4) require?
Answer: A separate electrode bonded to the power electrode system
In one- and two-family dwellings the bonding conductor must be as short as practicable and not over 6.0 m (20 ft). When that length cannot be met, the exception requires a separate communications electrode bonded to the power electrode system with a 6 AWG copper jumper. A larger wire or a splice does not satisfy the limit.
Reference: NFPA 70, National Electrical Code, 2023, 800.100(A)(4)
Nonconductive optical fiber cable will be installed exposed in a vertical shaft passing through three floors, with no raceway and no fireproof shaft. What is the minimum listed type?
Answer: OFNR
Section 770.113 permits riser-listed cable (OFNR, OFCR) or plenum-listed cable in vertical runs through floors. OFNG and OFN are general-purpose types with a lower fire rating, and OFC is a conductive general-purpose type.
Reference: NFPA 70, National Electrical Code, 2023, 770.113(D)
A cable company powers line amplifiers and an optical network terminal from the network side, not from a receptacle at the customer's building. Which article covers this arrangement?
Answer: Article 830, Network-Powered Broadband Communications Systems
Article 830 covers network-powered broadband communications systems, where power comes from the network. Article 840 covers premises-powered systems, where power is supplied from the customer's premises, and Article 645 deals with IT equipment rooms.
Reference: NFPA 70, National Electrical Code, 2023, 830.1
Sources
- ICC: Wyoming Electrical Contractor/Trades Bulletin (8/2025, PDF) (opens in a new tab)
- Wyoming State Fire Marshal: Electrical licensing (opens in a new tab)
- 041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
Questions last verified October 29, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.