Requirements at a glance
| Agency | Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE |
|---|---|
| Exam | 50 questions, 3 hours, 70% to pass |
| Experience | 1,000 hours over at least 6 months. |
| Books allowed | NEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index |
| Fees | $115 per exam to Pearson VUE; the license is $100 for 3 years. |
Technicians applying to the Wyoming State Fire Marshal for a limited sign technician license. You need 1,000 hours of experience over at least 6 months.
Official links
- Wyoming State Fire Marshal: electrical licensing (opens in a new tab)
- Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)
- Register with ICC at Pearson VUE (opens in a new tab)
- ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)
- 041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
How to get licensed, step by step
Check your experience
Make sure you meet the State Fire Marshal's requirements for the limited sign technician license: 1,000 hours over at least 6 months.
Wyoming State Fire Marshal: electrical licensing (opens in a new tab)
Apply and get approved
Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.
Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)
Register and pay with Pearson VUE
Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.
Pass the exam
Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.
Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
How to prepare
- ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
- Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
- Electrical signs and outline lighting (Article 600) is 12 of the 50 questions. Tab Article 600 and its parts on markings, disconnects and sign circuits.
- Transformers (neon transformers and transformers within the sign) are 8 questions; the other areas are 7 to 8 each.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential
Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Ugly's Electrical References (any edition)
Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.
Ferm's Fast Finder Index or Tom Henry's Key Word Index
Both are allowed, and a good index saves time on the questions you must look up.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
- Ugly's Electrical References (any edition)
- Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index
What's on the exam
Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Knowledge, Theory, Basic Load Calculations, and Definitions | 7 | |
| Feeders, Branch Circuits, and Conductors | 8 | |
| Wiring Methods | 8 | |
| Grounding and Bonding | 7 | |
| Transformers (Neon Transformers and Transformers Within the Sign) | 8 | |
| Electrical Signs and Outline Lighting (Article 600) | 12 |
Exam day details
- Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
- Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
- 50 questions in 3 hours; 70% to pass (041-5 Wyo. Code R. § 3).
- Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
- Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
- Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
- You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
- ICC exam number 239. "Electrical Signs and Outline Lighting (Article 600)" is 12 of the 50 questions, so weight your study there.
Frequently asked questions
What's on the Wyoming limited sign technician exam?
ICC's August 2025 outline, 50 questions: General Knowledge, Theory, Basic Load Calculations, and Definitions 7; Feeders, Branch Circuits, and Conductors 8; Wiring Methods 8; Grounding and Bonding 7; Transformers (Neon Transformers and Transformers Within the Sign) 8; Electrical Signs and Outline Lighting (Article 600) 12.
Which NEC edition do I bring to the Wyoming electrical exam?
ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.
Who gives the Wyoming electrical exams?
ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.
Free questions with answers
Show all 10 free questions and answers
In the NEC definitions, what does "within sight of" (in sight from) mean when a disconnect must be within sight of a sign?
Answer: Visible and not more than 50 ft from the equipment
Article 100 defines "in sight from, within sight from, within sight of" as visible and not more than 50 ft (15 m) distant from the equipment. A disconnect farther away or out of view is not within sight.
Reference: NFPA 70, National Electrical Code, 2023, Article 100, Definitions: In Sight From (Within Sight From, Within Sight Of)
Measured sign current is 14.4 amperes, and it runs all evening. Which standard breaker size is the smallest that can protect this branch circuit?
Answer: 20 A
Sign loads are continuous, so multiply by 125 percent: 14.4 x 1.25 = 18 A. The next standard rating (Table 240.6(A)) is 20 A. A 15 A device is below the 18 A minimum.
Reference: NFPA 70, National Electrical Code, 2023, 210.20(A); 600.5(B); Table 240.6(A)
Under 600.5(A), what must supply the required sign outlet at each pedestrian entrance to a commercial tenant space?
Answer: A branch circuit rated at least 20 A that supplies no other load
Section 600.5(A) requires an outlet at an accessible location at each entrance to each tenant space for sign or outline lighting, supplied by a branch circuit of at least 20 A that supplies no other load. Sharing the circuit with lighting or receptacles defeats that requirement.
Reference: NFPA 70, National Electrical Code, 2023, 600.5(A)
A sign has two ungrounded conductors, a neutral and an equipment grounding conductor on one circuit. How must they be run in a metal raceway?
Answer: All together in the same raceway
Section 300.3(B) requires all conductors of the same circuit, including the grounded conductor and equipment grounding conductor, to be in the same raceway, cable or trench. Splitting them causes inductive heating in metal raceways and impedance in the fault path.
Reference: NFPA 70, National Electrical Code, 2023, 300.3(B)
A box contains six 12 AWG circuit conductors that terminate or splice inside it, three equipment grounding conductors, one internal cable clamp set and one receptacle. Using 2.25 in.³ per 12 AWG, what is the minimum required box volume?
Answer: 22.5 in.³
Count each circuit conductor once (6), all equipment grounding conductors together once (1), the clamp set once (1) and the receptacle twice (2): 6 + 1 + 1 + 2 = 10 conductor equivalents. 10 x 2.25 = 22.5 in.³. Counting each EGC separately or omitting the clamp gives the wrong total.
Reference: NFPA 70, National Electrical Code, 2023, 314.16(B); Table 314.16(B)
Using Table 250.122, what is the minimum copper equipment grounding conductor for a circuit protected by a 60-ampere overcurrent device?
Answer: 10 AWG
Table 250.122 lists 12 AWG copper for 20 A, 10 AWG for 30, 40 and 60 A, and 8 AWG for 100 A. A 60 A device therefore needs 10 AWG copper.
Reference: NFPA 70, National Electrical Code, 2023, Table 250.122
What is the maximum secondary-circuit voltage permitted for a neon sign transformer or electronic power supply under Article 600?
Answer: 15,000 V, with not more than 7,500 V to ground
Section 600.23 limits transformer and electronic power supply secondary circuits to 15,000 volts, with not more than 7,500 volts to ground. This is why the transformer winding is often center-tapped and grounded. The other values are not NEC limits.
Reference: NFPA 70, National Electrical Code, 2023, 600.23(C)
Inside a large sign, a single-phase 5-kVA dry-type unit is fed at 480 V and protected on its primary side only. Applying the transformer protection table and the standard ampere ratings, how large may that primary fuse or breaker be?
Answer: 15 A
Primary current = 5,000 / 480 = 10.4 A. For 9 A or more, primary-only protection is 125 percent: 10.4 x 1.25 = 13.0 A. Note 1 allows the next higher standard rating, which is 15 A. A 20 A device would exceed the allowed rating.
Reference: NFPA 70, National Electrical Code, 2023, Table 450.3(B), Note 1; Table 240.6(A)
Under 600.3, how must fixed, mobile or portable signs, outline lighting systems and retrofit kits be furnished?
Answer: Listed and labeled, except for field-installed skeleton tubing
Section 600.3 requires fixed, mobile and portable signs, section signs, outline lighting and retrofit kits to be listed and labeled, provided with installation instructions and installed per that listing. Field-installed skeleton tubing is not required to be listed; it is installed under the Part II rules. Approval by the installer or inspector does not replace the listing.
Reference: NFPA 70, National Electrical Code, 2023, 600.3
A sign has lampholders for incandescent lamps. What additional marking is required next to the lampholders?
Answer: The maximum lamp wattage permitted for each lampholder
Section 600.4(B) requires signs and outline lighting with lampholders for incandescent lamps to be marked with the maximum allowable lamp wattage per lampholder. The marking must be permanent and located where it is visible during relamping, so the next person does not overlamp and overheat the sign.
Reference: NFPA 70, National Electrical Code, 2023, 600.4(B)
Sources
- ICC: Wyoming Electrical Contractor/Trades Bulletin (8/2025, PDF) (opens in a new tab)
- Wyoming State Fire Marshal: Electrical licensing (opens in a new tab)
- 041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)
Questions last verified October 29, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.