Wyoming licensing exam

Wyoming Limited Light Fixture Technician Exam: Practice Test & Licensing Guide

Wyoming's limited light fixture technician exam (ICC 599): 30 questions on luminaires (Article 410), conductors, grounding and locations. Open book, 70% to pass.

Questions
30
Time limit
2 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Fixtures/Luminaires (Article 410)

A pendant luminaire is to hang from a screw-shell lampholder with nothing else supporting it. Which luminaire may NOT be supported only by the screw shell?

Requirements at a glance

AgencyWyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal); exam by ICC through Pearson VUE
Exam30 questions, 2 hours, 70% to pass
Experience1,000 hours over at least 6 months.
Books allowedNEC or NEC Handbook (2023 per ICC's August 2025 bulletin), Ugly's (any edition), Ferm's Fast Finder, Tom Henry's Key Word Index
Fees$115 per exam to Pearson VUE; the license is $100 for 3 years.

Technicians applying to the Wyoming State Fire Marshal for a limited light fixture technician license. You need 1,000 hours of experience over at least 6 months.

How to get licensed, step by step

  1. Check your experience

    Make sure you meet the State Fire Marshal's requirements for the limited light fixture technician license: 1,000 hours over at least 6 months.

    Wyoming State Fire Marshal: electrical licensing (opens in a new tab)

  2. Apply and get approved

    Apply through the Wyoming electrical licensing portal. Wait for your approval notice, then allow 24 to 48 hours before you schedule so ICC can process your record.

    Apply and pay for your license (Wyoming electrical licensing portal) (opens in a new tab)ICC Wyoming Electrical Contractor/Trades Bulletin (PDF) (opens in a new tab)

  3. Register and pay with Pearson VUE

    Create a Pearson VUE account for ICC, pick the Wyoming exam, pay $115 and book a seat at a test center.

    Register with ICC at Pearson VUE (opens in a new tab)

  4. Pass the exam

    Bring your tabbed references. Your result shows right after the exam. If you fail, you must wait 10 days before you retest, and each attempt costs a new fee.

    Register with ICC at Pearson VUE (opens in a new tab)041-5 Wyo. Code R. § 3 (examinations and passing scores) (opens in a new tab)

How to prepare

  • ICC's August 2025 bulletin still lists the 2023 NEC, but Wyoming has adopted the 2026 NEC. Check ICC's exam catalog for your exam before you buy a book.
  • Tab your books before exam day. There's no time to look up every answer, so know where Articles 90, 100, 110, 210 to 250, 300 to 392, 430 and Chapter 9 sit.
  • Fixtures and luminaires (Article 410) are 15 of the 30 questions: half the exam. Tab Article 410.
  • Conductors (6), grounding (5) and locations (4) round it out. Use the index for location rules such as damp and wet locations.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2023 Edition (or the NEC Handbook)Essential

    Bring your own; the exam is based on the code provisions only. ICC's August 2025 bulletin lists the 2023 edition even though Wyoming adopted the 2026 NEC, so check ICC's exam catalog before you buy.

    NFPA store (opens in a new tab)Free online access (opens in a new tab)

  • Ugly's Electrical References (any edition)

    Allowed in the exam room. Formulas for Ohm's law, voltage drop, motors and transformers.

    Jones & Bartlett (opens in a new tab)

  • Ferm's Fast Finder Index or Tom Henry's Key Word Index

    Both are allowed, and a good index saves time on the questions you must look up.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC) or NEC Handbook (code provisions only are tested), 2023 Edition per ICC's August 2025 bulletin
  • Ugly's Electrical References (any edition)
  • Optional: Ferm's Fast Finder Index or Tom Henry's Key Word Index

What's on the exam

Official content outline from the International Code Council (ICC), delivered by Pearson VUE, (number of questions per topic):

TopicQuestions
Fixtures/Luminaires (Article 410)15
Conductors6
Grounding5
Locations4

Exam day details

  • Administered by the International Code Council (ICC), delivered by Pearson VUE, for the Wyoming Department of Fire Prevention and Electrical Safety (State Fire Marshal).
  • Fee: $115 per exam, paid to Pearson VUE when you schedule. State license fees are separate.
  • 30 questions in 2 hours; 70% to pass (041-5 Wyo. Code R. § 3).
  • Open book. ICC's August 2025 bulletin lists the 2023 NEC as the reference, even though Wyoming has adopted the 2026 NEC for enforcement. Check ICC's exam catalog for your exam before you buy a book.
  • Apply to the State Fire Marshal and get approved first, then register with ICC through Pearson VUE. ICC suggests waiting 24 to 48 hours after approval before you schedule.
  • Questions are four-option multiple choice and there is no penalty for guessing. Your result shows right after the exam.
  • You must wait 10 days before retaking a failed exam. Each attempt needs a new fee.
  • ICC exam number 599. "Fixtures/Luminaires (Article 410)" is 15 of the 30 questions, so weight your study there.

Frequently asked questions

What's on the Wyoming limited light fixture technician exam?

ICC's August 2025 outline, 30 questions: Fixtures/Luminaires (Article 410) 15; Conductors 6; Grounding 5; Locations 4.

Which NEC edition do I bring to the Wyoming electrical exam?

ICC's August 2025 bulletin lists the 2023 NEC, although Wyoming has adopted the 2026 NEC for enforcement. The NEC Handbook, Ugly's (any edition), Ferm's Fast Finder and Tom Henry's Key Word Index are also allowed. Check ICC's exam catalog before you buy a book.

Who gives the Wyoming electrical exams?

ICC, through Pearson VUE. The State Fire Marshal approves your application first; then you register and pay Pearson VUE $115 and test at a Pearson VUE center.

Free questions with answers

Show all 10 free questions and answers
  1. A pendant luminaire is to hang from a screw-shell lampholder with nothing else supporting it. Which luminaire may NOT be supported only by the screw shell?

    Answer: One that weighs 4 pounds and measures 18 inches in its largest dimension

    Under 410.30(A), a luminaire that weighs more than 6 lb or exceeds 16 in. in any dimension may not be supported by the screw shell of a lampholder. Only the 18-inch luminaire exceeds a limit; the 5-lb, 14-in. and 16-in. examples are within both limits.

    Reference: NFPA 70, National Electrical Code, 2023, 410.30(A)

  2. A 20-ampere, 120-volt branch circuit supplies only continuously operating 150-VA luminaires. What is the maximum number of luminaires the circuit can serve without exceeding the 80% continuous-load limit?

    Answer: 12

    Continuous load is limited to 80% of 20 A = 16 A, so 16 x 120 = 1,920 VA. 1,920 / 150 = 12.8, which must be rounded down to 12 luminaires because a 13th would exceed the limit (13 x 150 = 1,950 VA). Sixteen would use the full 2,400 VA rating.

    Reference: NFPA 70, National Electrical Code, 2023, 210.20(A)

  3. Branch-circuit conductors run within 3 inches of the ballast in a luminaire not marked for a different temperature. What insulation temperature rating is required?

    Answer: At least 90 degrees C

    Section 410.68 requires conductors within 3 in. of a ballast, LED driver or similar heat-producing component to have insulation rated for the temperature involved: not lower than 90 degrees C unless the luminaire is identified for another temperature. 60 or 75 degrees C insulation could be damaged.

    Reference: NFPA 70, National Electrical Code, 2023, 410.68

  4. What is the smallest size of fixture wire permitted by Article 402?

    Answer: 18 AWG

    Section 402.6 sets 18 AWG as the smallest fixture wire size. 16 AWG and larger are also used, but 18 AWG is the minimum, and 20 AWG is not a recognized fixture wire size here.

    Reference: NFPA 70, National Electrical Code, 2023, 402.6

  5. Using Table 402.5, what is the allowable ampacity of 14 AWG fixture wire?

    Answer: 17 amperes

    Table 402.5 lists 17 A for 14 AWG fixture wire. The 15 A value is the overcurrent device limit for 14 AWG branch-circuit conductors under 240.4(D), 20 A is the 12 AWG branch-circuit limit, and 23 A is the table value for 12 AWG fixture wire.

    Reference: NFPA 70, National Electrical Code, 2023, Table 402.5

  6. Using Table 250.122, what is the minimum size copper equipment grounding conductor for a lighting circuit protected by a 20-ampere circuit breaker?

    Answer: 12 AWG

    Table 250.122 is entered with the rating of the overcurrent device. For a 20 A device the minimum copper equipment grounding conductor is 12 AWG. 14 AWG is the size for a 15 A device, and 10 AWG is for 60 A.

    Reference: NFPA 70, National Electrical Code, 2023, Table 250.122

  7. A surface-mounted LED luminaire with a completely enclosed light source is mounted on the ceiling of a clothes closet. What is the minimum distance from the nearest point of the storage space?

    Answer: 12 inches

    Section 410.16(C) requires a surface-mounted LED or incandescent luminaire with a completely enclosed light source to be at least 12 in. from the nearest point of the storage space. 6 in. applies to surface fluorescent and recessed luminaires.

    Reference: NFPA 70, National Electrical Code, 2023, 410.16(C)

  8. A luminaire is installed directly above a combination tub/shower, inside the actual outside dimensions of the tub, 6 feet above the rim, where it is subject to shower spray. What marking does it need?

    Answer: Suitable for wet locations

    Section 410.10(D) requires a luminaire within the actual outside dimensions of a bathtub or shower, up to 8 ft above the rim or threshold, to be marked suitable for damp locations, or suitable for wet locations where it is subject to shower spray. Because this one is in the spray, it needs the wet-location marking.

    Reference: NFPA 70, National Electrical Code, 2023, 410.10(D)

  9. What must be done with exposed metal parts of a luminaire that could become energized?

    Answer: Connect them to the EGC, or insulate or isolate them as allowed

    Section 410.42 requires exposed metal parts to be connected to an equipment grounding conductor, or insulated from the equipment grounding conductor and other conducting surfaces, or inaccessible to unqualified persons. The grounded conductor must not be used for this purpose in a luminaire.

    Reference: NFPA 70, National Electrical Code, 2023, 410.42

  10. How may an equipment grounding conductor in a lighting circuit be identified?

    Answer: Bare, green, or green with yellow stripes

    Section 250.119 allows equipment grounding conductors to be bare, covered green, or green with one or more yellow stripes. White or gray identifies a grounded conductor (200.6), and red is commonly an ungrounded conductor.

    Reference: NFPA 70, National Electrical Code, 2023, 250.119

Sources

Questions last verified October 29, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.