Wisconsin licensing exam

Wisconsin Residential Journeyman Electrician Exam: Practice Test & Licensing Guide

The Wisconsin DSPS residential journeyman electrician exam: 100 open-book questions on the 2023 NEC and SPS 316 as they apply to dwellings, 4 hours, 70% to pass.

Questions
100
Time limit
4 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Electrical Theory and Calculations

A two-story house measures 30 ft by 40 ft on the outside of each floor. It also has an attached 22 ft by 24 ft garage and a 120 sq ft open front porch. Using the dwelling-unit general lighting load of 3 VA per square foot and Wisconsin's floor-area rule in SPS 316.220, how many 20-ampere, 120-volt branch circuits are needed for general lighting?

Requirements at a glance

AgencyWisconsin Department of Safety and Professional Services (DSPS)
ExperienceSee DSPS for residential journeyman requirements
Exam100 questions, 4 hours, 70% to pass
Books allowedOne binder (SPS 305, SPS 316, printed notes), the 2023 NEC codebook or handbook, and up to two bound reference books
Fees$95 at Pearson VUE ($30 at a DSPS site) per exam, plus the credential application fee; residential licenses need 18 CE hours

Electricians applying to DSPS for a residential journeyman license to wire one- and two-family dwellings.

How to get licensed, step by step

  1. Apply to DSPS

    Apply in LicensE for the residential journeyman electrician credential. DSPS issues exam instructions once your qualifications are met.

    Wisconsin Department of Safety and Professional Services (DSPS) (opens in a new tab)LicensE: apply for your credential (opens in a new tab)

  2. Schedule your exam

    Once your qualifications are met, DSPS sends an exam authorization. Schedule with Pearson VUE or, for electrical exams, a DSPS exam site. If you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.

    DSPS: trades exam information and fee schedule (opens in a new tab)Pearson VUE: Wisconsin DSPS Trades candidate handbook (PDF) (opens in a new tab)

  3. Take the exam

    100 questions, 4 hours, 70% to pass. Bring only the items DSPS lists; sticky notes, loose paper and removable tabs are not allowed.

    Wisconsin Admin. Code chapter SPS 316 (electrical) (opens in a new tab)DSPS permitted trades exam materials (PDF) (opens in a new tab)

  4. Results and licensing

    After you pass, wait 2 days, then submit your license application in LicensE. DSPS sends one exam authorization at a time, so a retake needs a new authorization. On two-part exams a failed part is retaken alone and all parts must be passed within 1 year.

    LicensE: apply for your credential (opens in a new tab)

How to prepare

  • Concentrate on dwelling-unit rules: receptacle and GFCI/AFCI requirements, branch circuits, service sizing for dwellings and Wisconsin's SPS 316 changes.
  • The exam uses the 2023 NEC. SPS 316.007 adopts it, and Wisconsin's changes are in SPS 316.080 and following: know where SPS 316 differs from the model NEC.
  • Put SPS 305 and SPS 316 in your binder with three-hole-punched notes, and tab your NEC with tabs that come with the bound book.
  • Every Wisconsin trades exam is open book, but DSPS limits what you can bring (a binder plus the listed books), and tabs must come with a bound book. Practice finding answers fast in your own binder.
  • DSPS publishes no content outline or topic weights, so our topic split is an estimate built from the reference lists DSPS prints. Counts and times come from DSPS's exam table.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC and SPS 316. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • One binder with Wis. Admin. Code SPS 305 and SPS 316 and your printed notes
  • 2023 National Electrical Code (NEC) codebook or handbook; SPS 316.007 adopts the 2023 NEC, and Wisconsin changes are in SPS 316.080 and following
  • Up to two printed, bound reference books (for example Ugly's, Ferm's Fast Finder, Tom Henry or Mike Holt series)

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Electrical Theory and Calculations10
General Requirements and Definitions (NEC Articles 90 to 110)8
Wiring and Protection (NEC Chapter 2)20
Wiring Methods and Materials (NEC Chapter 3)22
Equipment for General Use (NEC Chapter 4)16
Special Occupancies, Equipment and Conditions (NEC Chapters 5 to 7)8
Wisconsin Electrical Code and Licensing (SPS 316 and SPS 305)16

Exam day details

  • Administered by the Wisconsin Department of Safety and Professional Services (DSPS); exams are given by Pearson VUE or at a DSPS exam site.
  • Fee: $95 at Pearson VUE ($30 at a DSPS exam site). The credential application fee is separate.
  • 100 questions in 4 hours (DSPS exam table); open book; 70% to pass.
  • Open book: bring one binder (three-hole-punched printed notes and printed code), plus the other references DSPS lists for your exam. Loose paper, removable tabs, sticky notes and paperclips are not allowed; practice exams do not count as notes.
  • You can test at a Pearson VUE center or a DSPS exam site, but once you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.
  • The passing score is 70%. For two-part exams you need 70% in each part, a failed part is retaken alone, and all parts must be passed within 1 year (SPS 305.09(6)).
  • DSPS sends one exam authorization at a time. After you pass, wait 2 days, then apply for the license in LicensE.
  • DSPS publishes no content outline or topic weights (SPS 305.09(5) says the exams are based on a job analysis), so our topic split is an estimate built from the reference lists DSPS prints.

Note: DSPS publishes the question counts, time limits and permitted references but no content outline or topic weights, so our topic split is an estimate. Counts come from DSPS's exam table and were not checked against Pearson.

Frequently asked questions

What is different about the residential journeyman exam?

It is the same length as the journeyman exam and uses the same references (2023 NEC, SPS 305 and SPS 316), but our questions lean toward dwelling-unit wiring.

Which NEC edition does it use?

The 2023 NEC, adopted by SPS 316.007 with Wisconsin changes in SPS 316.080 and following.

How much does it cost?

$95 at Pearson VUE or $30 at a DSPS exam site.

Free questions with answers

Show all 10 free questions and answers
  1. A two-story house measures 30 ft by 40 ft on the outside of each floor. It also has an attached 22 ft by 24 ft garage and a 120 sq ft open front porch. Using the dwelling-unit general lighting load of 3 VA per square foot and Wisconsin's floor-area rule in SPS 316.220, how many 20-ampere, 120-volt branch circuits are needed for general lighting?

    Answer: 3 circuits

    SPS 316.220 replaces NEC 220.5(C): floor area comes from outside dimensions and excludes garages, open porches and unfinished areas. Area = 30 x 40 x 2 floors = 2,400 sq ft (the 528 sq ft garage and the porch are left out). Load = 2,400 x 3 = 7,200 VA; 7,200 / 120 = 60 A; 60 / 20 = 3 circuits. Counting the garage gives 2,928 sq ft, 8,784 VA, 73.2 A and a fourth circuit.

    Reference: Wisconsin Administrative Code SPS 316 (Register September 2026), SPS 316.220 (NEC 220.5(C)); NEC 220.41 and 210.11(A)

  2. A 120/240-volt residential panelboard is being installed in a utility room, with a block wall directly across from the panel front. What is the minimum clear working-space depth in front of the panel?

    Answer: 3 feet

    Table 110.26(A)(1) gives 3 ft (900 mm) for equipment at 0 to 150 volts to ground under all three conditions, and a 120/240-volt panel is 120 volts to ground. The 3 1/2 ft and 4 ft figures apply to conditions 2 and 3 only at 151 to 600 volts to ground; 2 1/2 ft is not a table value.

    Reference: NEC 2023, 110.26(A)(1), Table 110.26(A)(1)

  3. A kitchen has a straight wall countertop 4 feet long with no sink or range in that run. What is the maximum distance from any point along the wall line of the countertop to a receptacle outlet?

    Answer: 24 inches

    210.52(C)(1) requires countertop receptacles so that no point along the wall line of a wall countertop space is more than 24 in from a receptacle outlet in that space (wall spaces 12 in or wider are included). 12 in is too strict, and 36 in and 48 in exceed the limit.

    Reference: NEC 2023, 210.52(C)(1)

  4. An island countertop in a Wisconsin kitchen is flat across its whole surface, with no backsplash or divider, and there is no way to mount a receptacle within 20 inches above it, such as an overhead cabinet. Where may the required receptacle be mounted?

    Answer: Below the countertop, within 12 in. of it, and not where the top overhangs its base by more than 6 in.

    SPS 316.210(3)(b)2. gives a department exception to NEC 210.52(C)(3) for flat island and peninsular surfaces with no means of mounting a receptacle within 500 mm (20 in.) above the surface. The receptacle may be mounted below the countertop, not more than 300 mm (12 in.) below it, and not where the surface extends more than 150 mm (6 in.) beyond its support base.

    Reference: Wisconsin Administrative Code SPS 316 (Register September 2026), SPS 316.210(3)(b)2.

  5. Type NM cable runs along the side of wall studs to a device box that has a cable clamp. What are the maximum spacing between cable supports and the maximum distance from the box to the first support?

    Answer: 4 1/2 feet between supports and the first support within 12 inches of the box

    334.30 requires NM cable to be secured at intervals not exceeding 1.4 m (4 1/2 ft) and within 300 mm (12 in.) of every cable entry into a box, cabinet or fitting. The 3 ft, 6 ft, 6 in., 24 in. and 36 in. values are not the NM limits.

    Reference: NEC 2023, 334.30

  6. A single-pole wall switch will control a ceiling light in a new hallway of a dwelling. What does 404.2(C) generally require at the switch location?

    Answer: A grounded (neutral) conductor in the switch box, with limited exceptions

    404.2(C) requires a grounded circuit conductor to be provided at each switch location that controls lighting loads, so electronic controls can be powered; exceptions cover certain raceway or cable arrangements and specified locations. A switch loop without a neutral is no longer the default in new work.

    Reference: NEC 2023, 404.2(C)

  7. Which dwelling-unit receptacle must be listed tamper-resistant under 406.12?

    Answer: A 15-ampere, 125-volt receptacle on the wall of a bedroom

    406.12 requires 125-volt, 15- and 20-ampere receptacles in the listed dwelling-unit areas, including bedrooms, to be tamper-resistant. The exceptions are receptacles located more than 5 1/2 ft above the floor, receptacles that are part of a luminaire or appliance, certain dedicated single receptacles, and nongrounding replacement receptacles.

    Reference: NEC 2023, 406.12

  8. At a dwelling with a permanently installed in-ground pool, where must the required general-purpose 125-volt, 15- or 20-ampere receptacle be located relative to the inside wall of the pool?

    Answer: Between 6 and 20 feet from the inside wall

    680.22(A)(1) requires at least one general-purpose receptacle on a branch circuit located not less than 1.83 m (6 ft) and not more than 6.0 m (20 ft) from the inside wall of the pool, and not more than 6 ft 6 in. above the floor, platform or grade level. Receptacles closer than 6 ft are not permitted for this purpose.

    Reference: NEC 2023, 680.22(A)(1)

  9. An applicant for the residential journeyman exam completed three full-time semesters in an electrical-related program at a technical college. How much experience credit can the school time provide?

    Answer: 1,500 hours, since each semester counts as 500 hours

    SPS 305.447(3)(b) treats each full-time semester in an electrical-related program as equivalent to 500 hours of experience, with no more than 2,000 hours and 2 years of experience credited through education. Three semesters = 3 x 500 = 1,500 hours, which is under the 2,000 hour cap.

    Reference: Wisconsin Administrative Code SPS 305 (Register September 2026), SPS 305.447(3)(b)

  10. How many hours of acceptable continuing education must a licensed residential journeyman electrician obtain before the license expires, to renew?

    Answer: 18 hours

    SPS 305.447(6)(b)1. makes renewal contingent on at least 18 hours of acceptable continuing education before the expiration date, as specified in SPS 305.08 and Table 305.06. Twenty-four hours is the figure for some other credentials, not for this license.

    Reference: Wisconsin Administrative Code SPS 305 (Register September 2026), SPS 305.447(6)(b)1.

Sources

Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.