Wisconsin licensing exam

Wisconsin Journeyman Electrician Exam: Practice Test & Licensing Guide

The Wisconsin DSPS journeyman electrician exam: 100 open-book questions on the 2023 NEC and Wisconsin electrical rules (SPS 316), 4 hours, 70% to pass.

Questions
100
Time limit
4 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Wisconsin Electrical Code and Licensing (SPS 316 and SPS 305)

Which edition of NFPA 70, the National Electrical Code, does Wisconsin's electrical wiring chapter incorporate by reference?

Requirements at a glance

AgencyWisconsin Department of Safety and Professional Services (DSPS)
Experience3-year DOL/DWD apprenticeship, or 48 months and 8,000 hours (a 2-year degree counts 12 months and 2,000 hours); experience is reported on Form 8168
Exam100 questions, 4 hours, 70% to pass
Books allowedOne binder (SPS 305, SPS 316, printed notes), the 2023 NEC codebook or handbook, and up to two bound reference books
Fees$95 at Pearson VUE ($30 at a DSPS site) per exam, plus the credential application fee; journeyman credential $100 plus $35 application, 4-year term (renews June 30, 24 CE hours)

Electricians applying to DSPS for a journeyman license after a 3-year electrical apprenticeship, or 48 months and 8,000 hours of experience.

How to get licensed, step by step

  1. Apply to DSPS

    Apply in LicensE with proof of your apprenticeship or experience. DSPS issues exam instructions once your qualifications are met.

    Wisconsin Department of Safety and Professional Services (DSPS) (opens in a new tab)LicensE: apply for your credential (opens in a new tab)

  2. Schedule your exam

    Once your qualifications are met, DSPS sends an exam authorization. Schedule with Pearson VUE or, for electrical exams, a DSPS exam site. If you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.

    DSPS: trades exam information and fee schedule (opens in a new tab)Pearson VUE: Wisconsin DSPS Trades candidate handbook (PDF) (opens in a new tab)

  3. Take the exam

    100 questions, 4 hours, 70% to pass. Bring only the items DSPS lists; sticky notes, loose paper and removable tabs are not allowed.

    Wisconsin Admin. Code chapter SPS 316 (electrical) (opens in a new tab)DSPS permitted trades exam materials (PDF) (opens in a new tab)

  4. Results and licensing

    After you pass, wait 2 days, then submit your license application in LicensE. DSPS sends one exam authorization at a time, so a retake needs a new authorization. On two-part exams a failed part is retaken alone and all parts must be passed within 1 year.

    LicensE: apply for your credential (opens in a new tab)

How to prepare

  • Branch-circuit, feeder and service calculations and Chapter 3 wiring methods make up the biggest areas in our split.
  • The exam uses the 2023 NEC. SPS 316.007 adopts it, and Wisconsin's changes are in SPS 316.080 and following: know where SPS 316 differs from the model NEC.
  • Put SPS 305 and SPS 316 in your binder with three-hole-punched notes, and tab your NEC with tabs that come with the bound book.
  • Every Wisconsin trades exam is open book, but DSPS limits what you can bring (a binder plus the listed books), and tabs must come with a bound book. Practice finding answers fast in your own binder.
  • DSPS publishes no content outline or topic weights, so our topic split is an estimate built from the reference lists DSPS prints. Counts and times come from DSPS's exam table.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC and SPS 316. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • One binder with Wis. Admin. Code SPS 305 and SPS 316 and your printed notes
  • 2023 National Electrical Code (NEC) codebook or handbook; SPS 316.007 adopts the 2023 NEC, and Wisconsin changes are in SPS 316.080 and following
  • Up to two printed, bound reference books (for example Ugly's, Ferm's Fast Finder, Tom Henry or Mike Holt series)

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Electrical Theory and Calculations10
General Requirements and Definitions (NEC Articles 90 to 110)8
Wiring and Protection (NEC Chapter 2)18
Wiring Methods and Materials (NEC Chapter 3)18
Equipment for General Use (NEC Chapter 4)16
Special Occupancies, Equipment and Conditions (NEC Chapters 5 to 7)14
Wisconsin Electrical Code and Licensing (SPS 316 and SPS 305)16

Exam day details

  • Administered by the Wisconsin Department of Safety and Professional Services (DSPS); exams are given by Pearson VUE or at a DSPS exam site.
  • Fee: $95 at Pearson VUE ($30 at a DSPS exam site). The credential application fee is separate.
  • 100 questions in 4 hours (DSPS exam table); open book; 70% to pass.
  • Open book: bring one binder (three-hole-punched printed notes and printed code), plus the other references DSPS lists for your exam. Loose paper, removable tabs, sticky notes and paperclips are not allowed; practice exams do not count as notes.
  • You can test at a Pearson VUE center or a DSPS exam site, but once you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.
  • The passing score is 70%. For two-part exams you need 70% in each part, a failed part is retaken alone, and all parts must be passed within 1 year (SPS 305.09(6)).
  • DSPS sends one exam authorization at a time. After you pass, wait 2 days, then apply for the license in LicensE.
  • DSPS publishes no content outline or topic weights (SPS 305.09(5) says the exams are based on a job analysis), so our topic split is an estimate built from the reference lists DSPS prints.

Note: DSPS publishes the question counts, time limits and permitted references but no content outline or topic weights, so our topic split is an estimate. Counts come from DSPS's exam table and were not checked against Pearson.

Frequently asked questions

Which NEC edition is on the Wisconsin journeyman exam?

The 2023 NEC. SPS 316.007 adopts it, and Wisconsin's changes are in SPS 316.080 and following.

What can I bring into the exam?

One binder (SPS 305, SPS 316 and printed notes), a 2023 NEC codebook or handbook, and up to two bound reference books such as Ugly's or Mike Holt.

How much does the exam cost?

$95 at Pearson VUE or $30 at a DSPS exam site. The license application fee is separate.

Free questions with answers

Show all 10 free questions and answers
  1. Which edition of NFPA 70, the National Electrical Code, does Wisconsin's electrical wiring chapter incorporate by reference?

    Answer: The 2023 edition, with the department's changes in SPS 316

    SPS 316.007(1)(a) incorporates NFPA 70 National Electrical Code, 2023 edition, including temporary interim amendments and errata issued before January 1, 2025. The department's own changes, additions and omissions are in SPS 316.080 and the sections that follow. Open the 2023 NEC first, then check SPS 316 for a Wisconsin change.

    Reference: Wis. Admin. Code SPS 316, SPS 316.007(1)(a)

  2. A municipality that inspects electrical wiring under SPS 316.011 must keep applications, plans, correction orders, permits and inspection records. For how long after completion does SPS 316.013(4)(a) require them to be kept?

    Answer: 7 years after completion

    SPS 316.013(4)(a)2. requires municipalities that enforce the code by ordinance to keep applications, plans, forms, correction orders, correspondence, permits and inspection records for 7 years after completion. Inspectors working under a state contract instead follow the records terms in that contract (sub. (4)(b)).

    Reference: Wis. Admin. Code SPS 316, SPS 316.013(4)(a)2.

  3. A 240-volt single-phase circuit carries 12 amperes through a resistive load. What is the resistance of the load?

    Answer: 20 ohms

    Ohm's law gives R = E / I = 240 V / 12 A = 20 ohms. The 0.05 ohm answer inverts the formula (I / E), 2,880 multiplies E by I (that is watts, not ohms), and 10 ohms divides 120 V by 12 A, using the wrong voltage.

    Reference: Electrical theory (Ohm's law and power formulas), E = I x R (Ohm's law)

  4. A 480Y/277-volt panelboard is installed with exposed live parts on its front and a grounded concrete wall directly opposite (Condition 2). What is the minimum depth of working space in front of the panelboard under Table 110.26(A)(1)?

    Answer: 3-1/2 feet

    Table 110.26(A)(1) lists, for 151 to 600 volts to ground, 3 ft for Condition 1 (live parts on one side, nothing live or grounded on the other), 3-1/2 ft for Condition 2 (live parts on one side, grounded parts on the other) and 4 ft for Condition 3 (live parts on both sides). A grounded wall opposite the live parts is Condition 2.

    Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, Table 110.26(A)(1)

  5. A 120-volt branch circuit supplies 24 amperes of continuous load and 10 amperes of noncontinuous load, and the overcurrent device is not listed for 100 percent operation. Using 210.20(A), what is the minimum overcurrent device rating?

    Answer: 40 amperes

    Section 210.20(A) requires the overcurrent device to carry the noncontinuous load plus 125 percent of the continuous load. 24 A x 1.25 = 30 A, and 30 A + 10 A = 40 A, which is a standard rating under 240.6(A). The 34 A answer adds the loads without the 125 percent factor, 30 A applies it to the continuous load only, and 45 A is a larger device than the minimum.

    Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 210.20(A)

  6. Cable is run through holes bored in wood studs. How far from the nearest edge of the stud must each hole be so that no steel protection plate is needed under 300.4(A)(1)?

    Answer: 1-1/4 inches

    Section 300.4(A)(1) requires bored holes to be at least 1-1/4 in. from the nearest edge of the wood framing member, or the cable must be protected by a steel plate or bushing at least 1/16 in. thick. Smaller edge distances leave the cable open to nail or screw damage.

    Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 300.4(A)(1)

  7. A metal box will hold three 12/2 NM cables with ground, each with two insulated 12 AWG conductors that terminate in the box. The box also contains one duplex receptacle and two internal cable clamps. Using 2.25 cubic inches per 12 AWG conductor, what is the minimum box volume under 314.16(B)?

    Answer: 22.5 cubic inches

    Count each insulated conductor that terminates in the box: 3 cables x 2 = 6. All equipment grounding conductors together count as 1. One yoke or strap (the duplex receptacle) counts as 2. All internal cable clamps together count as 1. The total is 6 + 1 + 2 + 1 = 10 allowances x 2.25 = 22.5 cu in. Leaving out the clamp allowance gives 20.25, counting each ground separately gives 12 allowances (27.0), and leaving out the device and clamps gives 8 allowances (18.0).

    Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 314.16(B)

  8. When sizing the branch-circuit conductors for a general-purpose three-phase induction motor, which full-load current value does 430.6(A)(1) require?

    Answer: The value in Table 430.250, not the nameplate current

    Section 430.6(A)(1) requires the full-load current values of Table 430.247 through Table 430.250 to be used, instead of the nameplate current, to determine conductor ampacity, switch ratings and short-circuit and ground-fault protection. The nameplate current is used separately for overload protection under 430.32.

    Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 430.6(A)(1)

  9. A single continuous-duty 30-horsepower, 460-volt, three-phase squirrel-cage motor has a Table 430.250 full-load current of 40 A. What is the minimum ampacity of its branch-circuit conductors under 430.22?

    Answer: 50 amperes

    Section 430.22 requires branch-circuit conductors for a single continuous-duty motor to have an ampacity of at least 125 percent of the Table 430.250 full-load current: 40 x 1.25 = 50 A. The 40 A answer leaves out the factor, 46 A is the 115 percent disconnect figure from 430.110, and 100 A is the 250 percent device multiplier.

    Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 430.22 and Table 430.250

  10. Which description fits a Class I, Division 1 location under 500.5(B)(1)?

    Answer: Ignitable concentrations of flammable gases or vapors can exist under normal operating conditions

    Class I locations involve flammable gases, vapors or liquids. In Division 1 an ignitable concentration can exist under normal operating conditions (or frequently because of repair, leakage or equipment failure). Existence only under abnormal conditions describes Division 2, dust describes Class II and fibers or flyings describe Class III.

    Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 500.5(B)(1)

Sources

Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.