Requirements at a glance
| Agency | Wisconsin Department of Safety and Professional Services (DSPS) |
|---|---|
| Experience | A Wisconsin plumbing apprenticeship (letter from the Bureau of Apprenticeship Standards) |
| Exam | Part 1: 87 questions and Part 2: 120 questions, 3 hours each, 70% in each part |
| Books allowed | One binder (Wis. Stat. 145, SPS 305, SPS 381 to 387 and others, notes), NFPA 13D, NFPA 24 (journeyman), POWTS manuals, the Multi-Purpose Piping Systems Design Manual and scale rulers |
| Fees | $90 per part at Pearson VUE, plus the credential fee ($180 plus $10 application, 4-year term, renews March 31, 24 CE hours) |
Plumbers applying to DSPS for a journeyman license after a Wisconsin plumbing apprenticeship.
Official links
- Wisconsin Department of Safety and Professional Services (DSPS) (opens in a new tab)
- DSPS: trades exam information and fee schedule (opens in a new tab)
- Pearson VUE: Wisconsin DSPS Trades candidate handbook (PDF) (opens in a new tab)
- Wisconsin Admin. Code chapter SPS 382 (plumbing) (opens in a new tab)
- Wisconsin Statutes chapter 145 (plumbing) (opens in a new tab)
- DSPS permitted trades exam materials (PDF) (opens in a new tab)
How to get licensed, step by step
Apply to DSPS
Apply in LicensE with your apprenticeship completion letter. DSPS issues exam instructions once your qualifications are met.
Wisconsin Department of Safety and Professional Services (DSPS) (opens in a new tab)LicensE: apply for your credential (opens in a new tab)
Schedule your exam
Once your qualifications are met, DSPS sends an exam authorization. Schedule with Pearson VUE or, for electrical exams, a DSPS exam site. If you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.
DSPS: trades exam information and fee schedule (opens in a new tab)Pearson VUE: Wisconsin DSPS Trades candidate handbook (PDF) (opens in a new tab)
Take the exam
Part 1: 87 questions and Part 2: 120 questions, 3 hours each, 70% in each part. Bring only the items DSPS lists; sticky notes, loose paper and removable tabs are not allowed.
Wisconsin Admin. Code chapter SPS 382 (plumbing) (opens in a new tab)Wisconsin Statutes chapter 145 (plumbing) (opens in a new tab)DSPS permitted trades exam materials (PDF) (opens in a new tab)
Results and licensing
After you pass, wait 2 days, then submit your license application in LicensE. DSPS sends one exam authorization at a time, so a retake needs a new authorization. On two-part exams a failed part is retaken alone and all parts must be passed within 1 year.
How to prepare
- Wisconsin's plumbing code is its own (SPS 382 to 384), not the IPC or UPC. Learn the Wisconsin drain, vent and water sizing tables and the POWTS rules in SPS 383.
- The exam has two parts, each passed at 70%; a failed part is retaken alone and all parts must be passed within 1 year.
- Every Wisconsin trades exam is open book, but DSPS limits what you can bring (a binder plus the listed books), and tabs must come with a bound book. Practice finding answers fast in your own binder.
- DSPS publishes no content outline or topic weights, so our topic split is an estimate built from the reference lists DSPS prints. Counts and times come from DSPS's exam table.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Wisconsin plumbing code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Wisconsin plumbing code: Wis. Stat. 145 and SPS 381 to 387Essential
Wisconsin's plumbing code is its own, not the IPC. Put these chapters in your binder.
Official reference list (as published by the testing agency)
- One binder (PHCC binders are accepted) with Wis. Stat. chapter 145, SPS 305, SPS 381 to 387, Wis. Stat. 106, SPS 302, SPS 325 and your notes
- NFPA 13D (2019 edition); NFPA 24 (2019 edition) on the journeyman list
- POWTS component manuals (At-Grade Pressure Distribution, Holding Tank, In-Ground Soil Absorption, Mound, Pressure Distribution), the Multi-Purpose Piping Systems Design Manual and scale rulers
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Wisconsin Plumbing Licensing and Law (Wis. Stat. 145, SPS 305) | 10 | |
| Definitions and Standards (SPS 381) | 6 | |
| Intent, Basic Requirements and Administration (SPS 382 Subchapters I and II) | 8 | |
| Materials, Fixtures and Appliances (SPS 384) | 12 | |
| Drain and Vent Systems (SPS 382 Subchapter III) | 18 | |
| Water Supply and Distribution (SPS 382 Subchapter IV) | 18 | |
| Storm and Clear-Water Drainage, Special Systems and Installation (SPS 382.36, 382 Subchapters V and VI) | 8 | |
| Private Onsite Wastewater Treatment Systems (SPS 383 and 385) | 8 | |
| Pipe Sizing and Plan Reading | 12 |
Exam day details
- Administered by the Wisconsin Department of Safety and Professional Services (DSPS); exams are given by Pearson VUE or at a DSPS exam site.
- Fee: $90 per part at Pearson VUE. The credential application fee is separate.
- Part 1 has 87 questions and Part 2 has 120, with 3 hours for each part (DSPS exam table, not checked against Pearson). Open book; 70% in each part.
- Wisconsin has its own plumbing code (SPS 382 to 384), not the International Plumbing Code. Our questions follow the Wisconsin text.
- NFPA 13D, NFPA 24, the POWTS component manuals and the Multi-Purpose Piping Systems Design Manual are not freely readable, so our questions stay in SPS 381 to 387 and Wis. Stat. 145.
- Open book: bring one binder (three-hole-punched printed notes and printed code), plus the other references DSPS lists for your exam. Loose paper, removable tabs, sticky notes and paperclips are not allowed; practice exams do not count as notes.
- You can test at a Pearson VUE center or a DSPS exam site, but once you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.
- The passing score is 70%. For two-part exams you need 70% in each part, a failed part is retaken alone, and all parts must be passed within 1 year (SPS 305.09(6)).
- DSPS sends one exam authorization at a time. After you pass, wait 2 days, then apply for the license in LicensE.
- DSPS publishes no content outline or topic weights (SPS 305.09(5) says the exams are based on a job analysis), so our topic split is an estimate built from the reference lists DSPS prints.
Note: DSPS publishes the question counts, time limits and permitted references but no content outline or topic weights, so our topic split is an estimate. Counts come from DSPS's exam table and were not checked against Pearson.
Frequently asked questions
Is the Wisconsin plumbing exam based on the IPC or UPC?
Neither. Wisconsin has its own plumbing code, SPS 382 to 384, plus Wis. Stat. chapter 145.
How does the two-part exam work?
You need 70% in each part. A failed part is retaken alone, and you must pass all parts within 1 year.
Where can I take the plumbing exam?
Only at Pearson VUE centers (Eau Claire, Madison, Brookfield, Kenosha, Ashwaubenon or Milwaukee).
Free questions with answers
Show all 10 free questions and answers
A journeyman plumber-restricted service licensee must complete how many hours of continuing education to renew, and how does that compare with a full journeyman plumber?
Answer: 12 hours, half of the 24 hours required of a full journeyman plumber
SPS 305.94 (6) (b) 1. sets 12 hours for the restricted service journeyman, while SPS 305.93 (6) (b) 1. sets 24 hours for the full journeyman. The restricted license is narrower in scope and carries half the continuing education.
Reference: Wis. Admin. Code SPS 305, SPS 305.94 (6) (b) 1. and SPS 305.93 (6) (b) 1.
A vent pipe is called a "vent stack" under SPS 381.01 when it provides air for a drain stack of how many branch intervals?
Answer: 5 or more branch intervals
SPS 381.01 (269) defines a vent stack as a vertical vent pipe that provides air for a drain stack of 5 or more branch intervals. A branch interval is a vertical distance of 8 feet or more between horizontal branch connections to the stack.
Reference: Wis. Admin. Code SPS 381, SPS 381.01 (35) and (269)
Under SPS 382.10 (2), which fixtures must each dwelling connected to a POWTS or public sewer have at a minimum?
Answer: One water closet, one wash basin, one kitchen sink, and one bathtub or shower
SPS 382.10 (2) (b) requires one water closet, one wash basin, one kitchen sink and one bathtub or shower for each such dwelling (camping units excepted). A system recognized under ch. SPS 391 may replace the water closet.
Reference: Wis. Admin. Code SPS 382, SPS 382.10 (2) (b)
A 3-inch horizontal branch drain is installed in a wall cavity. What is the minimum pitch required for this horizontal branch drain under SPS 382.30 (5) (a)?
Answer: 1/8 inch per foot
Horizontal branch drains larger than 2 inches in diameter need a minimum pitch of 1/8 inch per foot under SPS 382.30 (5) (a) 2. The 1/4 inch per foot value applies only to branch drains of 2 inches or less.
Reference: Wis. Admin. Code SPS 382, SPS 382.30 (5) (a) 2.
What is the general minimum horizontal separation between a private water main or water service and a sanitary sewer, per SPS 382.40 (8) (b) 3.?
Answer: 5 feet
SPS 382.40 (8) (b) 3. requires 5 feet horizontally, with exceptions in subds. 4. and 5. A pressurized sewer allows 3 feet if the water pipe bottom is 18 inches above it.
Reference: Wis. Admin. Code SPS 382, SPS 382.40 (8) (b) 3.
Which drilling and tapping of water supply piping is allowed under SPS 382.40 (8) (h)?
Answer: Corporation cocks and self-tapping valves serving individual appliances
SPS 382.40 (8) (h) prohibits drilling and tapping of water supply piping except for corporation cocks on a water service or private water main and self-tapping valves serving individual plumbing appliances.
Reference: Wis. Admin. Code SPS 382, SPS 382.40 (8) (h)
What is the minimum size of a storm or clearwater sump, unless the manufacturer specifies otherwise or an elevator pit applies, per SPS 382.36 (8) (a) 4. a.?
Answer: 16 inches top, 14 inches bottom, 22 inches deep
SPS 382.36 (8) (a) 4. a. sets 16 inches diameter at the top, 14 at the bottom and 22 inches depth, but never smaller than the manufacturer requires for pump run time. A sump in an elevator pit may be 12 by 12 inches.
Reference: Wis. Admin. Code SPS 382, SPS 382.36 (8) (a) 4.
A site drains 7,800 square feet of roof, 3,250 square feet of pavement and 5,200 square feet of lawn to one storm sewer. By the area method in SPS 382.36 (5) (a) 1., what is the total peak flow?
Answer: 450 gpm
Roof: 7,800 / 26 = 300 gpm. Pavement: 3,250 / 32.5 = 100 gpm. Lawn: 5,200 / 104 = 50 gpm. Total 300 + 100 + 50 = 450 gpm. Using one divisor for the whole area gives a wrong total.
Reference: Wis. Admin. Code SPS 382, SPS 382.36 (5) (a) 1.
A POWTS serves a 4-bedroom dwelling with combined graywater, clear water and blackwater. Using SPS 383.43 (2) and (3) (a), what is the design wastewater flow?
Answer: 600 gallons per day
Estimated daily flow F = 100 gallons x 4 bedrooms = 400 gpd. The design flow is at least 150% of that: 400 x 1.5 = 600 gpd. The figure 400 forgets the 150% factor, and 800 wrongly doubles the flow instead of applying 150%.
Reference: Wis. Admin. Code SPS 383, SPS 383.43 (2) and (3) (a)
Under SPS 384.20 (5) (o) 4., what are the minimum water closet spacing requirements?
Answer: 15 inches from the center to a side wall and 30 inches center to center, with 24 inches in front
SPS 384.20 (5) (o) 4. requires at least 15 inches from the center to any side wall or obstruction, at least 30 inches center to center between water closets, and at least 24 inches of clearance in front to any wall, fixture or door.
Reference: Wis. Admin. Code SPS 384, SPS 384.20 (5) (o) 4.
Sources
- DSPS: trades exam information and fee schedule (opens in a new tab)
- Pearson VUE: Wisconsin DSPS Trades candidate handbook (opens in a new tab)
- Wisconsin Admin. Code chapter SPS 382 (plumbing) (opens in a new tab)
Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.