Requirements at a glance
| Agency | Wisconsin Department of Safety and Professional Services (DSPS) |
|---|---|
| Experience | 6 years of 1,000 hours of electrical experience (a degree counts up to 3,000 hours), or 3 years plus an electrical engineering degree, or a PE, architect or designer credential; exam waived for a Wisconsin master electrician, ICC electrical or commercial electrical inspector, or IAEI master electrical inspector |
| Exam | 50 questions, 4 hours, 70% to pass |
| Books allowed | One binder (SPS 305, SPS 316, printed notes), the 2023 NEC codebook or handbook, and up to two bound reference books |
| Fees | $95 at Pearson VUE ($25 at a DSPS site), plus the credential fee ($40 plus $15 application, 24 CE hours) |
Inspectors applying to DSPS for a commercial electrical inspector credential (SPS 305.62). The exam route needs 6 years of 1,000 hours of electrical experience, or 3 years plus an electrical engineering degree, or a PE, architect or designer credential.
Official links
- Wisconsin Department of Safety and Professional Services (DSPS) (opens in a new tab)
- DSPS: trades exam information and fee schedule (opens in a new tab)
- Pearson VUE: Wisconsin DSPS Trades candidate handbook (PDF) (opens in a new tab)
- Wisconsin Admin. Code chapter SPS 316 (electrical) (opens in a new tab)
- DSPS permitted trades exam materials (PDF) (opens in a new tab)
How to get licensed, step by step
Apply to DSPS
Apply in LicensE with proof of your experience, degree or qualifying certification (SPS 305.62).
Wisconsin Department of Safety and Professional Services (DSPS) (opens in a new tab)LicensE: apply for your credential (opens in a new tab)
Schedule your exam
Once your qualifications are met, DSPS sends an exam authorization. Schedule with Pearson VUE or, for electrical exams, a DSPS exam site. If you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.
DSPS: trades exam information and fee schedule (opens in a new tab)Pearson VUE: Wisconsin DSPS Trades candidate handbook (PDF) (opens in a new tab)
Take the exam
50 questions, 4 hours, 70% to pass. Bring only the items DSPS lists; sticky notes, loose paper and removable tabs are not allowed.
Wisconsin Admin. Code chapter SPS 316 (electrical) (opens in a new tab)DSPS permitted trades exam materials (PDF) (opens in a new tab)
Results and licensing
After you pass, wait 2 days, then submit your license application in LicensE. DSPS sends one exam authorization at a time, so a retake needs a new authorization. On two-part exams a failed part is retaken alone and all parts must be passed within 1 year.
How to prepare
- Expect Wisconsin inspection authority and SPS 316 changes alongside the 2023 NEC.
- The exam uses the 2023 NEC. SPS 316.007 adopts it, and Wisconsin's changes are in SPS 316.080 and following: know where SPS 316 differs from the model NEC.
- Put SPS 305 and SPS 316 in your binder with three-hole-punched notes, and tab your NEC with tabs that come with the bound book.
- Every Wisconsin trades exam is open book, but DSPS limits what you can bring (a binder plus the listed books), and tabs must come with a bound book. Practice finding answers fast in your own binder.
- DSPS publishes no content outline or topic weights, so our topic split is an estimate built from the reference lists DSPS prints. Counts and times come from DSPS's exam table.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC and SPS 316. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 EditionEssential
DSPS lets you bring a 2023 NEC codebook or handbook. SPS 316.007 adopts the 2023 NEC; Wisconsin's changes are in SPS 316.080 and following.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Wisconsin Admin. Code chapters SPS 305 and SPS 316Essential
Both go in your binder. SPS 316 adopts the NEC and lists Wisconsin's changes; SPS 305 covers credential and exam rules.
Official reference list (as published by the testing agency)
- One binder with Wis. Admin. Code SPS 305 and SPS 316 and your printed notes
- 2023 National Electrical Code (NEC) codebook or handbook; SPS 316.007 adopts the 2023 NEC, and Wisconsin changes are in SPS 316.080 and following
- Up to two printed, bound reference books (for example Ugly's, Ferm's Fast Finder, Tom Henry or Mike Holt series)
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Electrical Theory and Calculations | 8 | |
| General Requirements and Definitions (NEC Articles 90 to 110) | 10 | |
| Wiring and Protection (NEC Chapter 2) | 16 | |
| Wiring Methods and Materials (NEC Chapter 3) | 16 | |
| Equipment for General Use (NEC Chapter 4) | 16 | |
| Special Occupancies, Equipment and Conditions (NEC Chapters 5 to 7) | 14 | |
| Wisconsin Electrical Code and Inspection Authority (SPS 316 and SPS 305) | 20 |
Exam day details
- Administered by the Wisconsin Department of Safety and Professional Services (DSPS); exams are given by Pearson VUE or at a DSPS exam site.
- Fee: $95 at Pearson VUE ($25 at a DSPS exam site). The credential application fee is separate.
- 50 questions in 4 hours (DSPS exam table); open book; 70% to pass.
- You can skip the exam if you hold a Wisconsin master electrician license, an ICC electrical or commercial electrical inspector certification, or an IAEI master electrical inspector certification.
- Open book: bring one binder (three-hole-punched printed notes and printed code), plus the other references DSPS lists for your exam. Loose paper, removable tabs, sticky notes and paperclips are not allowed; practice exams do not count as notes.
- You can test at a Pearson VUE center or a DSPS exam site, but once you choose Pearson you cannot switch back. Plumbing and HVAC Qualifier exams are given only at Pearson centers.
- The passing score is 70%. For two-part exams you need 70% in each part, a failed part is retaken alone, and all parts must be passed within 1 year (SPS 305.09(6)).
- DSPS sends one exam authorization at a time. After you pass, wait 2 days, then apply for the license in LicensE.
- DSPS publishes no content outline or topic weights (SPS 305.09(5) says the exams are based on a job analysis), so our topic split is an estimate built from the reference lists DSPS prints.
Note: DSPS publishes the question counts, time limits and permitted references but no content outline or topic weights, so our topic split is an estimate. Counts come from DSPS's exam table and were not checked against Pearson.
Frequently asked questions
Which references can I bring?
The same list as the electrician exams: one binder (SPS 305, SPS 316 and notes), a 2023 NEC codebook or handbook, and up to two bound reference books.
Can I skip the exam?
Yes, if you hold a Wisconsin master electrician license, an ICC electrical or commercial electrical inspector certification, or an IAEI master electrical inspector certification.
How much does it cost?
$95 at Pearson VUE or $25 at a DSPS exam site. The credential is $40 plus a $15 application fee.
Free questions with answers
Show all 10 free questions and answers
A branch circuit in a retail store supplies a 24-ampere continuous load and an 8-ampere noncontinuous load. The overcurrent device is not listed for operation at 100 percent of its rating. What is the minimum standard overcurrent device rating?
Answer: 40 amperes
The overcurrent device must carry the noncontinuous load plus 125 percent of the continuous load: (24 x 1.25) + 8 = 30 + 8 = 38 amperes. The next standard rating in 240.6(A) is 40 amperes. 35 amperes is the standard size above the plain sum of 32 amperes, which ignores the 125 percent rule. 30 amperes is too small, and 50 amperes is larger than any calculation supports.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 210.20(A) and 240.6(A)
An inspector finds a stack of conduit bundles stored in front of a panelboard in a commercial mechanical room. Which Code rule is violated?
Answer: The working space must be kept clear and may not be used for storage
110.26(B) requires working space to be kept clear and not used for storage. A panelboard is allowed in a mechanical room, and the 110.26(A)(3) height rule applies to the working space rather than to a ceiling above it. Storage in the working space blocks safe access in an emergency.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 110.26(B)
In an office break room, a 125-volt, 20-ampere receptacle is installed on a wall 4 feet from the edge of a sink bowl. Under 210.8(B), what is required?
Answer: GFCI protection for the receptacle
210.8(B) requires GFCI protection for receptacles in areas with sinks and permanent provisions for food or beverage preparation, and for receptacles within 6 feet of the top inside edge of a sink bowl. Four feet is within the 6-foot distance. AFCI protection is addressed separately in 210.12 and is not a substitute, and a cover plate gives no ground-fault protection.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 210.8(B)(3) and (B)(7)
A 400-ampere feeder breaker supplies tap conductors 20 feet long that end in a single circuit breaker supplying a panelboard, and the taps are in a raceway. Under the 25-foot tap rule of 240.21(B)(2), what is the minimum ampacity of the tap conductors?
Answer: 133 amperes, one-third of the feeder device rating
The 25-foot tap rule requires the tap conductor ampacity to be at least one-third of the rating of the overcurrent device protecting the feeder: 400 / 3 = 133.3 amperes. The taps must also terminate in a single circuit breaker or set of fuses that limits the load to the tap ampacity, and must be protected from physical damage, for example in a raceway. The 10-foot tap rule works differently and does not use this fraction. One-half and one-quarter are not factors of this rule.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 240.21(B)(2)
Underground feeder conductors in rigid metal conduit will be buried under a lawn behind a commercial building, with no concrete cover. Using Table 300.5(A), what is the minimum cover for the "all locations not specified" row?
Answer: 6 inches
In Table 300.5(A), the all-locations row gives 6 inches for rigid metal conduit or intermediate metal conduit (Column 2). 18 inches is the value for EMT or nonmetallic raceways listed for direct burial without concrete (Column 3), and 24 inches is for direct-buried cables or conductors (Column 1). 12 inches applies to certain lower-voltage circuits with GFCI protection and overcurrent protection of 20 amperes or less.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 300.5(A) and Table 300.5(A), Column 2
PVC conduit listed for direct burial, without concrete encasement, will run under a commercial parking lot. Under Table 300.5(A), what is the minimum cover?
Answer: 24 inches
Table 300.5(A) shows 24 inches (600 mm) of cover for all of the wiring methods in Columns 1 through 5 under streets, highways, roads, alleys, driveways and parking lots, with the one exception of dwelling driveways and parking areas used only for dwelling purposes. The 18 inches in the all-locations row for nonmetallic raceways does not apply under a commercial parking lot, and 6 inches is the all-locations value for rigid metal conduit.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, Table 300.5(A), row for streets, highways, roads, alleys, driveways and parking lots
A circuit directory in a new commercial panelboard lists two spare breaker positions with no load connected. Under 408.4(A), what must the directory say about spares?
Answer: Spare positions with an unused overcurrent device must be identified in the directory as spare
408.4(A)(3) requires a circuit directory description that is clear, evident and specific to the purpose of each circuit, including spare positions with an unused overcurrent device. The directory must be legible and permanent, not dependent on transient conditions of occupancy such as a tenant name, and clear in explaining abbreviations and symbols.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 408.4(A)(3) and (A)(5)
Two snap switches in a common box in a commercial building control separate 480Y/277-volt lighting circuits on different phases (480 volts between adjacent devices). No barrier is installed. Under 404.8(B), what is the result?
Answer: It is not permitted unless identified barriers separate the devices, because the voltage between adjacent devices exceeds 300 volts
404.8(B) prohibits grouping snap switches with other snap switches, receptacles or similar devices in one enclosure unless the voltage between adjacent devices does not exceed 300 volts or identified, securely installed barriers separate the devices. Phase-to-phase on a 480Y/277 system is 480 volts, which exceeds 300 volts, so the barriers are required. The voltage to ground is not the measure in this rule.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 404.8(B)
A wastewater treatment building has a legally required standby generator under Article 701. After a loss of the normal supply, what is the maximum time to make power available?
Answer: 60 seconds
701.12 requires legally required standby power to be available within the time required for the application but not to exceed 60 seconds. The 10-second limit is for emergency systems under 700.12. The 30-second and 120-second figures are not in either article.
Reference: NFPA 70 National Electrical Code (NEC), 2023 edition, 701.12
A rough-in inspection of a commercial wiring installation was requested, and the inspection agency has not inspected it. Under SPS 316.013(3)(c), when may the installer conceal or energize the wiring, other than a service?
Answer: After 2 business days from notice
SPS 316.013(3)(c)1. allows the concealment or energizing of electrical wiring, other than an electrical service, to proceed if the inspection has not been completed within 2 business days after notification is received, or as otherwise agreed between the installer and the inspection agency. Services are excluded from this rule and wait for the inspection. Otherwise the wiring must stay accessible, exposed and not energized.
Reference: Wis. Admin. Code SPS 316, SPS 316.013(3)(b) and (c)1.
Sources
- DSPS: trades exam information and fee schedule (opens in a new tab)
- Pearson VUE: Wisconsin DSPS Trades candidate handbook (opens in a new tab)
- Wisconsin Admin. Code chapter SPS 316 (electrical) (opens in a new tab)
Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.