West Virginia licensing exam

West Virginia Residential Contractor Exam: Practice Test & Licensing Guide

The Prov exam for West Virginia residential contractors: 60 open-book questions on plan reading, sitework, concrete, masonry, carpentry and finishes, mostly from the 2018 IRC.

Questions
60
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Concrete

A contractor is pouring an exterior carport slab and a garage floor slab in an area of severe weathering potential. What minimum specified 28-day compressive strength does Table R402.2 require?

Requirements at a glance

AgencyWest Virginia Contractor Licensing Board (Division of Labor); exams by Prov
When you need itContracting work of $5,000 or more residential or $25,000 or more commercial (W. Va. Code 30-42-3)
ExamsResidential contractor exam: 60 questions, 3 hours, 70%, plus the Contractor Licensing Act exam
Books allowedIRC 2018, Residential Carpentry and Repair study guide, Masonry and Sitework for the Residential Contractor
Fees$59.95 per Prov exam; $90 annual Board license fee (28 CSR 2, 5.5)

Contractors applying for the West Virginia Residential Contractor classification, which covers the crafts needed to build, repair or improve residential structures except those licensed separately, such as electrical work.

How to get licensed, step by step

  1. Pick your classification

    Every contractor passes the Contractor Licensing Act exam plus a trade exam where one exists. Check the classification definitions in 28 CSR 2.

    West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)28 CSR 2 (Contractor Licensing Board rule) (opens in a new tab)

  2. Apply to the Board

    Apply through the Contractor Licensing Board at the Division of Labor, (304) 558-7890.

    West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)

  3. Take your exams with Prov

    Register at provexam.com or call (866) 720-7768. 3 hours per exam, 70% to pass, score on the spot, no waiting period before a retake.

    Register for your exam with Prov (opens in a new tab)Contractor Licensing Board candidate bulletin (Prov) (opens in a new tab)

How to prepare

  • Carpentry is 15 of 60 questions; tab the IRC framing chapters (Chapters 5 to 8).
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Residential Code 2018 (ICC), about 40% of questions
  • Study Guide for Residential Carpentry and Repair, 2nd Edition, 2014 (Pearson), about 38%
  • Masonry and Sitework for the Residential Contractor, 2nd Edition (Pearson), about 25%

What's on the exam

Official content outline from Prov, Inc. (number of questions per topic):

TopicQuestions
Plan Reading9
Sitework6
Concrete9
Masonry9
Carpentry15
Interior Finish3
Exterior Finish3
Safety OSHA6

Exam day details

  • Administered by Prov, Inc. for the West Virginia Contractor Licensing Board.
  • Fee: $59.95 to Prov per exam, whether first try or retake. Licensing board application and license fees are separate.
  • 60 questions in 3 hours; 70% to pass.
  • Pass the Contractor Licensing Act exam as well; every West Virginia contractor takes it.
  • Open book: bring the references the bulletin lists (any older or newer edition of the same book is allowed, but the exam is scored on the edition shown in the bulletin). Prepare them only by highlighting and attaching permanent tabs; handwritten notes, moveable tabs and sticky notes are not allowed.
  • Computer-based at a Prov testing center or at home with Examroom remote proctoring. Only a simple 4-function calculator is allowed.
  • You get your score at the testing center. There is no waiting period between attempts and no limit on retakes; retake fees equal the first-try fee.
  • Change or cancel at least 3 business days before your test date or you forfeit the fee. You can ask for a review of your exam after failing it at least twice with a score within 10 points of 70%.

Frequently asked questions

What's on the West Virginia residential contractor exam?

60 questions: carpentry 15, plan reading 9, concrete 9, masonry 9, sitework 6, safety (OSHA) 6, interior finish 3 and exterior finish 3.

Which books are allowed?

The 2018 IRC, the Residential Carpentry and Repair study guide and Masonry and Sitework for the Residential Contractor. Highlighting and permanent tabs only.

Free questions with answers

Show all 10 free questions and answers
  1. A contractor is pouring an exterior carport slab and a garage floor slab in an area of severe weathering potential. What minimum specified 28-day compressive strength does Table R402.2 require?

    Answer: 3,500 psi, air entrained

    Table R402.2 lists porches, carport slabs, steps exposed to weather and garage floor slabs at 3,500 psi for severe weathering, and footnote d requires air entrainment (5 to 7 percent total air). 2,500 psi applies to negligible weathering and 3,000 psi to moderate weathering.

    Reference: 2018 International Residential Code, Table R402.2

  2. A solid masonry bearing wall is 8 inches thick and is supported vertically by floor or roof framing. Using Table R606.6.4 (solid or solid grouted bearing wall, ratio 20), what is the maximum unsupported height?

    Answer: 13 feet 4 inches

    Table R606.6.4 allows a height-to-thickness ratio of 20 for solid or solid grouted bearing walls. 20 x 8 in = 160 in = 13 ft 4 in. The ratio of 18 (all other bearing walls) would give 144 in = 12 ft, and the interior nonbearing ratio of 36 would give 288 in = 24 ft.

    Reference: 2018 International Residential Code, Table R606.6.4

  3. A nominal 2x10 floor joist (actual depth 9 1/4 inches) must have a hole bored for a drain line. Under R502.8.1, which hole is permitted in the middle of the span?

    Answer: A 2 1/2-inch hole centered with at least 2 inches of wood above and below it

    R502.8.1 limits bored holes to one-third of the member depth (9.25 / 3 = 3.08 in.) and requires at least 2 inches between the hole edge and the top or bottom of the member. The 2 1/2-inch hole centered leaves (9.25 - 2.5) / 2 = 3.4 in. each side, so it passes. The 3 1/2-inch hole exceeds 3.08 in., and the other two violate the 2-inch edge distance.

    Reference: 2018 International Residential Code, R502.8.1

  4. How deep may a notch be cut in the top of a nominal 2x10 joist (actual depth 9 1/4 inches) away from the ends and outside the middle third of the span, per R502.8.1?

    Answer: Not more than 1.54 inches (one-sixth of the depth)

    R502.8.1 limits notches in solid lumber joists to one-sixth of the member depth: 9.25 / 6 = 1.54 in. Notches may not be in the middle one-third of the span and may not be longer than one-third of the depth. One-fourth of the depth applies only to notches at the ends of the member, and one-third is the limit for hole diameter.

    Reference: 2018 International Residential Code, R502.8.1

  5. A concrete driveway and sidewalk sit within 10 feet of a foundation wall where 6 inches of fall is not possible. Under the R401.3 exception, what slope must impervious surfaces have away from the building?

    Answer: At least 2 percent

    The exception to R401.3 requires impervious surfaces within 10 feet of the building foundation to slope not less than 2 percent away from the building (about 1/4 inch per foot), and drains or swales where 6 inches of fall is not available.

    Reference: 2018 International Residential Code, R401.3, Exception

  6. On a floor plan drawn at 1/4 inch = 1 foot, a wall measures 6 3/4 inches. What is the actual wall length?

    Answer: 27 feet

    At 1/4 inch per foot, each inch on the drawing equals 4 feet. 6.75 in x 4 ft/in = 27 ft. Dividing by 2 gives 13 ft 6 in (a 1/2-inch scale mistake), and 54 ft doubles the answer.

    Reference: General trade practice, General trade practice: reading an architectural scale

  7. Which drawing shows a vertical slice through the building so that footings, wall framing and roof framing can be read?

    Answer: A building section

    A building (wall) section is a vertical cut drawing that shows footing size, foundation wall, floor framing, wall framing and roof construction. A floor plan is a horizontal cut, and a site plan shows lot lines and setbacks.

    Reference: General trade practice, General trade practice: reading construction drawings

  8. 1/2-inch gypsum board is applied to ceiling joists at 24 inches on center, perpendicular to the framing. Under Table R702.3.5, what is the maximum fastener spacing for nails and for screws?

    Answer: 7 inches for nails; 12 inches for screws

    Table R702.3.5 gives 1/2-inch ceiling board perpendicular to framing at 24 inches on center a maximum nail spacing of 7 inches and screw spacing of 12 inches. The 8-inch nail and 16-inch screw spacing is for walls at 16 inches on center.

    Reference: 2018 International Residential Code, Table R702.3.5

  9. How must No. 15 asphalt felt used as the water-resistive barrier on exterior walls be lapped under R703.2?

    Answer: Horizontally with the upper layer over the lower, lapped 2 inches, and 6 inches at vertical joints

    R703.2 requires one layer of No. 15 felt applied horizontally with the upper layer lapped over the lower layer not less than 2 inches, with vertical joints lapped not less than 6 inches. The barrier must be continuous to the top of the walls.

    Reference: 2018 International Residential Code, R703.2

  10. At what height above a lower level must construction employees on a walking/working surface with an unprotected side or edge be protected from falling?

    Answer: 6 feet

    29 CFR 1926.501(b)(1) requires each employee on a walking/working surface with an unprotected side or edge 6 feet or more above a lower level to be protected by guardrail systems, safety net systems or personal fall arrest systems. The 10-foot height is the scaffold trigger in 1926.451(g)(1).

    Reference: 29 CFR 1926 Subpart M, 1926.501(b)(1)

Sources

Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.