Requirements at a glance
| Agency | West Virginia Contractor Licensing Board (Division of Labor); exams by Prov |
|---|---|
| When you need it | Contracting work of $5,000 or more residential or $25,000 or more commercial (W. Va. Code 30-42-3) |
| Exams | Multifamily contractor exam: 75 questions, 3 hours, 70%, plus the Contractor Licensing Act exam |
| Books allowed | IBC 2021, Study Guide for Commercial Carpentry, Study Guide for Structural Steel |
| Fees | $59.95 per Prov exam; $90 annual Board license fee (28 CSR 2, 5.5) |
Contractors applying for the West Virginia Multifamily classification: construction, repair or improvement of a structure containing two or more residential units, or work incidental to it.
Official links
- West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)
- Contractor Licensing Board candidate bulletin (Prov) (opens in a new tab)
- Register for your exam with Prov (opens in a new tab)
- West Virginia Code 30-42 (Contractor Licensing Act) (opens in a new tab)
- 28 CSR 2 (Contractor Licensing Board rule) (opens in a new tab)
How to get licensed, step by step
Pick your classification
Every contractor passes the Contractor Licensing Act exam plus a trade exam where one exists. Check the classification definitions in 28 CSR 2.
West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)28 CSR 2 (Contractor Licensing Board rule) (opens in a new tab)
Apply to the Board
Apply through the Contractor Licensing Board at the Division of Labor, (304) 558-7890.
West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)
Take your exams with Prov
Register at provexam.com or call (866) 720-7768. 3 hours per exam, 70% to pass, score on the spot, no waiting period before a retake.
Register for your exam with Prov (opens in a new tab)Contractor Licensing Board candidate bulletin (Prov) (opens in a new tab)
Get licensed
Send your results and the license fee to the Board.
West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)West Virginia Code 30-42 (Contractor Licensing Act) (opens in a new tab)
How to prepare
- The Board bulletin lists the 2021 IBC (76% of questions) although West Virginia adopts the 2018 edition. Use the 2021 IBC if you can.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IBC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Building Code (IBC), 2021 EditionEssential
Listed in the Board bulletin for the multifamily exam (about 76% of questions), although West Virginia adopts the 2018 edition. Older or newer editions are allowed in the room.
ICC store (opens in a new tab)Read free (ICC Digital Codes) (opens in a new tab)
Study Guide for Commercial Carpentry, 2nd Edition, 2014; Study Guide for Structural Steel, 2012 (Pearson)
Allowed in the exam room. About 21% and 2% of the multifamily exam.
Official reference list (as published by the testing agency)
- International Building Code 2021 (ICC), about 76% of questions
- Study Guide for Commercial Carpentry, 2nd Edition, 2014 (Pearson), about 21%
- Study Guide for Structural Steel, 2012 (Pearson), about 2%
What's on the exam
Official content outline from Prov, Inc. (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Plan Reading | 9 | |
| Sitework | 6 | |
| Concrete | 9 | |
| Masonry | 8 | |
| Structural Steel | 4 | |
| Carpentry | 15 | |
| Roofing, Siding, and Insulation | 6 | |
| Doors and Windows | 6 | |
| Interior Finish | 3 | |
| Safety-OSHA | 6 | |
| Exterior Finishes | 3 |
Exam day details
- Administered by Prov, Inc. for the West Virginia Contractor Licensing Board.
- Fee: $59.95 to Prov per exam, whether first try or retake. Licensing board application and license fees are separate.
- 75 questions in 3 hours; 70% to pass.
- Pass the Contractor Licensing Act exam as well; every West Virginia contractor takes it.
- Open book: bring the references the bulletin lists (any older or newer edition of the same book is allowed, but the exam is scored on the edition shown in the bulletin). Prepare them only by highlighting and attaching permanent tabs; handwritten notes, moveable tabs and sticky notes are not allowed.
- Computer-based at a Prov testing center or at home with Examroom remote proctoring. Only a simple 4-function calculator is allowed.
- You get your score at the testing center. There is no waiting period between attempts and no limit on retakes; retake fees equal the first-try fee.
- Change or cancel at least 3 business days before your test date or you forfeit the fee. You can ask for a review of your exam after failing it at least twice with a score within 10 points of 70%.
Note: The Contractor Licensing Board bulletin lists the 2021 IBC for this exam, but the West Virginia State Building Code (87 CSR 4) adopts the 2018 edition. Our questions follow the 2021 IBC text and avoid sections that changed between editions where possible. Confirm the edition with the Board before you test.
Frequently asked questions
What's on the West Virginia multifamily exam?
75 questions: carpentry 15, plan reading 9, concrete 9, masonry 8, roofing, siding and insulation 6, doors and windows 6, sitework 6, safety (OSHA) 6, structural steel 4, interior finish 3 and exterior finishes 3.
Which IBC edition is the exam based on?
The Board bulletin lists the 2021 IBC, even though the West Virginia State Building Code adopts the 2018 edition. Older or newer editions are allowed in the room, but the exam is scored on the bulletin edition.
Free questions with answers
Show all 10 free questions and answers
A paved walkway lies 6 feet from the foundation of a multifamily building and drains away from the wall. What minimum slope does the code set for an impervious surface within 10 feet of the foundation, unless an exception applies?
Answer: 2 percent
Section 1804.4 sets impervious surfaces within 10 feet of the foundation at not less than 2 percent away from the building. The 5 percent figure applies to the soil, not to paving. The exception for less than 2 percent covers door landings and ramps that must meet the egress or accessibility provisions.
Reference: 2021 International Building Code, 1804.4
Concrete for foundation walls of a three-story Group R-2 apartment building will be exposed to the weather on its vertical surfaces. What is the minimum specified compressive strength f'c the exception to 1904.1 requires?
Answer: 3,000 psi
The exception to Section 1904.1 sets f'c at not less than 3,000 psi for R-2 and R-3 occupancies not more than three stories above grade where concrete is in basement walls, foundation walls, exterior walls and other vertical surfaces exposed to weather. The 2,500 psi figure is the Table 1808.8.1 value for foundations generally.
Reference: 2021 International Building Code, 1904.1
A masonry chimney passes through a flat roof of a townhouse building. The ridge of a higher roof section lies 8 feet horizontally from the chimney and rises 4 feet above the point where the chimney passes through the roof. What is the minimum height of the chimney above the point where it passes through the roof?
Answer: 6 feet
Section 2113.9 requires a chimney to extend at least 2 feet above any part of the building within 10 feet, and at least 3 feet above the highest point where it passes through the roof. The ridge is within 10 feet and 4 feet higher, so 4 + 2 = 6 feet, which is greater than the 3-foot minimum. Using only the 3-foot rule ignores the 10-foot, 2-foot rule.
Reference: 2021 International Building Code, 2113.9
When anchor rods are set in a concrete foundation to receive a steel column base plate, which statement matches the code on protrusion of the threaded ends through the connected material?
Answer: The threads must fully engage the nuts, but the protrusion must not exceed the thread length
Section 2204.3 requires anchor rods to be set per the approved construction documents, with the threaded ends fully engaging the nuts but not protruding farther than the length of threads on the bolts.
Reference: 2021 International Building Code, 2204.3
Using the fastening schedule in Table 2304.10.2 with 16d common nails, how is the second (upper) top plate fastened to the first top plate along its length?
Answer: 16d common nails at 16 inches on center, face nailed
Item 12 of Table 2304.10.2 (Top plate to top plate) lists 16d common nails at 16 inches on center, face nail. The 24-inch spacing is the stud-to-stud value for 16d common nails, which is a different line.
Reference: 2021 International Building Code, Table 2304.10.2, item 12
What is the minimum roof slope on which asphalt shingles may be installed under the code?
Answer: Two units vertical in 12 units horizontal (2:12)
Section 1507.2.2 allows asphalt shingles only on slopes of 2:12 (17 percent) or greater. For slopes from 2:12 up to 4:12, double underlayment is required. Four-in-twelve is the slope above which single underlayment suffices, not the minimum slope.
Reference: 2021 International Building Code, 1507.2.2
What minimum clear opening width must a required egress door provide, and how is the width measured for a swinging door?
Answer: 32 inches, measured between the face of the door and the stop with the door open 90 degrees
Section 1010.1.1 requires a minimum clear opening width of 32 inches, measured between the face of the door and the stop with the door open 90 degrees. The rough opening is wider than the clear opening.
Reference: 2021 International Building Code, 1010.1.1
When is gypsum wallboard permitted to be installed in a new building under construction, relative to weather protection?
Answer: Only after weather protection for the installation is provided
Section 2508.2.1 prohibits installing gypsum wallboard, lath or plaster until weather protection for the installation is provided. Section 2508.2 also bars its use as an exterior surface directly exposed to the weather.
Reference: 2021 International Building Code, 2508.2.1
At what height above a lower level must employees on a walking or working surface with an unprotected side or edge be protected from falling on a construction site?
Answer: 6 feet or more
29 CFR 1926.501(b)(1) requires fall protection (guardrails, safety nets or personal fall arrest) for employees on a surface with an unprotected side or edge 6 feet or more above a lower level. The 10-foot figure applies to scaffolds under 1926.451(g)(1).
Reference: 29 CFR Part 1926 (OSHA Construction Standards), 29 CFR 1926.501(b)(1)
On a floor plan drawn at 1/4 inch = 1 foot, a wall measures 5 3/4 inches. What is the actual wall length?
Answer: 23 feet
At 1/4 inch = 1 foot, each inch on the drawing is 4 feet. 5.75 inches x 4 = 23 feet. Reading the line with the 1/2-inch scale gives 11 feet 6 inches (5.75 x 2), and with the 1/8-inch scale gives 46 feet (5.75 x 8).
Reference: General trade practice, Plan reading: architectural scale
Sources
- Prov: West Virginia Contractor Licensing Board Candidate Information Bulletin (CIB 2026.05.07) (opens in a new tab)
- West Virginia Contractor Licensing Board (Division of Labor) (opens in a new tab)
- Prov: register for West Virginia exams (opens in a new tab)
- West Virginia Code Chapter 30, Article 42 (Contractor Licensing Act) (opens in a new tab)
- 28 CSR 2: Contractor Licensing Board rule (opens in a new tab)
Questions last verified November 17, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.