Washington Residential Service Plumber Exam (PL04): Practice Test & Licensing Guide

Washington's residential service plumber exam: 65 closed-book questions in 90 minutes from the 2015 UPC with Washington amendments, the mechanical code and Washington plumbing law. 70% to pass.

Questions
65
Time limit
90 min
Passing score
70%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Washington Plumbing Law and Scope (RCW 18.106 and WAC 296-400A)

A residential service plumber (PL04) is offered four jobs in single-family houses. Which one is inside the PL04 scope?

Requirements at a glance

AgencyWashington State Department of Labor & Industries (L&I) Plumber Certification; exams by PSI
Exam65 questions, 90 minutes, 70% to pass, closed book
Books allowedNone: closed book
FeesL&I's application fee plus PSI's exam fee (see the exam details above).
TimingApproval is good for 1 year. Wait 14 days after a fail. Pay the certificate fee within 90 days of passing.

Plumbers applying to L&I for the PL04 residential service plumber certificate: service, repair and replacement of existing fixtures and piping in single-family homes and duplexes, plus drain cleaning and leak repair.

How to get licensed, step by step

  1. Apply to L&I

    Apply to L&I for the PL04 residential service plumber exam with proof of your experience.

    Washington L&I: Plumber examination (opens in a new tab)

  2. Study

    Study the 2015 UPC with Washington amendments, the residential mechanical code provisions and RCW 18.106 / WAC 296-400A.

    PSI Washington Plumbing Candidate Information Bulletin (opens in a new tab)

  3. Schedule with PSI

    After L&I approves you, PSI emails you. Schedule online or at 855-746-8173.

    PSI: schedule Washington plumbing exams (opens in a new tab)

  4. Pass and certify

    70% to pass. Pay your certificate fee within 90 days.

    Washington L&I: Plumber examination (opens in a new tab)

How to prepare

  • Drainage, traps and vents are the biggest share. Know trap seal, trap arm lengths, cleanouts and fixture unit basics.
  • Know the PL04 scope exactly: existing fixtures and piping outside the wall or above the floor in single-family homes and duplexes, plus drain cleaning and leak repair.
  • Water heaters come up often: relief valves, expansion tanks, strapping and venting clearances.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

  • Uniform Plumbing Code (UPC), 2015 (IAPMO), with Washington State amendmentsEssential

    Study copy only: the plumber exam is closed book. WABO sells the 2015 UPC with Washington amendments.

    WABO (opens in a new tab)

Official reference list (as published by the testing agency)
  • Uniform Plumbing Code (UPC), 2015 (IAPMO), with Washington State amendments (closed book: study only)
  • Mechanical code with Washington amendments (residential provisions)
  • Chapter 18.106 RCW and Chapter 296-400A WAC (Washington plumbing law and rules)

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Fixtures and Water Heaters10
Water Supply and Sizing10
Drainage, Traps and Vents18
General Regulations, Materials and Definitions9
Residential Mechanical Code6
Washington Plumbing Law and Scope (RCW 18.106 and WAC 296-400A)8
Safety and Trade Knowledge4

Exam day details

  • Administered by PSI, for the Washington State Department of Labor & Industries (L&I) Plumber Certification.
  • Fee: L&I's application and exam fee plus PSI's exam fee; PSI's bulletin prints only the three-part fee ($84) and the $52 retest portion fee.
  • One closed-book part: 65 questions, 90 minutes, 70% to pass.
  • L&I says the questions come from the UPC with amendments, the mechanical code with amendments, RCWs and WACs and other related sources.
  • The exam is based on the 2015 Uniform Plumbing Code with Washington State Building Code Council amendments, even though Washington now enforces the 2021 UPC (WAC 51-56). Study the 2015 edition.
  • The PL04 scope (RCW 18.106.010): in single-family dwellings and duplexes, service, repair or replace existing fixtures, piping and fittings outside the wall or above the floor; in any residential structure, drain cleaning and leak repair.
  • Apply to L&I first; approval is good for 1 year. 70% to pass. After a fail you reapply to L&I and wait 14 days. Pay your certificate fee within 90 days of passing.
  • L&I describes the exam's subject areas but not how many questions come from each; our topic weights are estimates.

Frequently asked questions

What's on the Washington residential service plumber exam?

65 questions from the 2015 UPC with Washington amendments, the mechanical code and Washington plumbing law. Our estimated split: Fixtures and Water Heaters 10; Water Supply and Sizing 10; Drainage, Traps and Vents 18; General Regulations, Materials and Definitions 9; Residential Mechanical Code 6; Washington Plumbing Law and Scope (RCW 18.106 and WAC 296-400A) 8; Safety and Trade Knowledge 4.

Which UPC edition is the Washington plumber exam on?

The 2015 Uniform Plumbing Code with Washington amendments, per L&I and PSI. Washington enforces the 2021 UPC on job sites, but the exam has not changed editions. The exam is closed book; PSI hands out Tables 702.1, 610.3, 610.4 and 610.10.

What can a Washington residential service plumber do?

Service, repair or replace existing fixtures, piping and fittings outside the wall or above the floor in single-family homes and duplexes, and do drain cleaning and leak repairs in any residential structure (RCW 18.106.010). New installations need a residential or journey level plumber.

Free questions with answers

Show all 10 free questions and answers
  1. A residential service plumber (PL04) is offered four jobs in single-family houses. Which one is inside the PL04 scope?

    Answer: Replacing an existing kitchen faucet and the angle stops under the sink

    RCW 18.106.010(11)(a) lets a residential service plumber service, repair or replace previously existing fixtures, piping and fittings that are outside the interior wall or above the floor in single-family dwellings and duplexes. Replacing a faucet and its stops fits. Roughing in a new bathroom and any new-construction work are barred by (11)(c), and concealed in-wall repiping is not outside the interior wall.

    Reference: Chapter 18.106 RCW, RCW 18.106.010(11)

  2. A homeowner wants a floor-mounted, back-outlet water closet to replace an old wall-hung unit. Which requirement applies?

    Answer: The soil pipe must be at least 3 inches and offset or reducing flanges are not allowed

    Section 402.6.3 requires floor-mounted, back-outlet bowls to be set level with a 90-degree angle between floor and wall, secured to both the wall outlet flange and the floor with corrosion-resistant fasteners, and served by a soil pipe not less than 3 inches. Offset, eccentric or reducing floor flanges are prohibited.

    Reference: 2015 Uniform Plumbing Code, Section 402.6.3

  3. What is the minimum diameter of a lavatory waste outlet and fixture tailpiece?

    Answer: 1-1/4 inches

    Section 407.5 requires lavatories to have a waste outlet and fixture tailpiece not less than 1-1/4 inches in diameter, with an approved stopper or strainer. Bathtubs need 1-1/2 inches (409.2) and showers 2 inches (408.4).

    Reference: 2015 Uniform Plumbing Code, Section 407.5

  4. What is the maximum length of a flexible corrugated copper or stainless steel connector used to supply a dishwasher?

    Answer: 120 inches

    Section 604.12 limits flexible corrugated connectors of copper, copper alloy or stainless steel to 30 inches for fixture connectors, 72 inches for washing machine connectors and 120 inches for dishwasher and icemaker connectors. The 30-inch limit applies to faucets and toilets, not dishwashers.

    Reference: 2015 Uniform Plumbing Code, Section 604.12

  5. A house has a PEX manifold (parallel distribution) in the crawl space, so the manifold valves are not accessible. What does Section 606.5 require?

    Answer: A separate shutoff valve immediately ahead of each fixture or appliance served

    Section 606.5 lets parallel systems put each fixture's control valve at the manifold, identified with the fixture served. Where the manifold is in an attic, crawl space or other location that is not accessible, a separate shutoff valve is required immediately ahead of each fixture or appliance.

    Reference: 2015 Uniform Plumbing Code, Section 606.5

  6. Three lavatories sit side by side in one room. When may they share a single trap?

    Answer: When the waste outlets are not more than 30 inches apart and the trap is centrally located

    Section 1001.2 permits one trap to serve not more than three lavatories immediately adjacent to each other in the same room, where the waste outlets are not more than 30 inches apart and the trap is centrally located. A larger trap size is not the condition.

    Reference: 2015 Uniform Plumbing Code, Section 1001.2

  7. A horizontal branch will serve a kitchen sink with dishwasher (2 DFU), a clothes washer (3 DFU) and a laundry tub (2 DFU), with no water closets. Using Tables 702.1 and 703.2, what is the minimum branch size?

    Answer: 2 inches

    Total load: 2 + 3 + 2 = 7 DFU. Table 703.2 allows 1 DFU on a 1-1/2 inch horizontal drain and 8 DFU on a 2 inch horizontal drain, so 2 inches is the minimum. 3 inches would be needed only above 8 DFU or for a water closet.

    Reference: 2015 Uniform Plumbing Code, Table 703.2

  8. A plumber needs to connect a cast-iron drain to a smaller IPS steel pipe. Which item does Section 316.1 prohibit as the adapter?

    Answer: A cast-iron or copper alloy body cleanout

    Section 316.1 requires proper-size increasers, reducers or reducing fittings where different sizes connect, and says copper alloy or cast-iron body cleanouts shall not be used as a reducer or adapter from cast-iron drainage pipe to iron pipe size (IPS) pipe.

    Reference: 2015 Uniform Plumbing Code, Section 316.1

  9. While replacing a drain, a plumber notches a floor joist deeply and weakens it. What does Section 312.11 require?

    Answer: Reinforcing, repairing or replacing the member

    Section 312.11 requires a structural member weakened or impaired by cutting or notching to be reinforced, repaired or replaced so it is left in a safe structural condition under the building code. A nail plate protects pipe; it does not restore the member.

    Reference: 2015 Uniform Plumbing Code, Section 312.11

  10. A plumber reroutes the condensate drain from an air conditioning coil. What minimum slope does the mechanical code require for the horizontal run?

    Answer: 1/8 inch per foot

    Mechanical code Section 307.2.1 requires condensate piping to maintain a minimum horizontal slope in the direction of discharge of not less than 1/8 unit vertical in 12 units horizontal (1 percent). 1/4 inch per foot is the usual minimum for plumbing drains, not condensate lines.

    Reference: 2015 International Mechanical Code (WA State Mechanical Code), Section 307.2.1