Question 1 of 10Cross-Connection Concepts and Degree of Hazard

A building has a storage tank on its roof whose water surface is 46 feet above a service-level backflow assembly. About how much backpressure does that water column exert on the assembly's downstream side? (Use 0.433 psi per foot of water.)

Requirements at a glance

AgencyWashington State Department of Labor & Industries (L&I) Plumber Certification; exams by PSI
Exam55 questions, 90 minutes, 70% to pass, closed book
Books allowedNone: closed book
FeesL&I's application fee plus PSI's exam fee (see the exam details above).
TimingApproval is good for 1 year. Wait 14 days after a fail. Pay the certificate fee within 90 days of passing.

Backflow assembly testers applying to L&I for the PL30 backflow specialty plumber certificate, which allows maintenance and repair (not installation or replacement) of backflow assemblies inside buildings. You need a current Department of Health backflow assembly tester (BAT) certificate.

How to get licensed, step by step

  1. Apply to L&I

    Get your Department of Health backflow assembly tester (BAT) certificate first, then apply to L&I for the PL30 backflow specialty plumber exam.

    Washington L&I: Plumber examination (opens in a new tab)

  2. Study

    L&I names no references. Study the materials Washington lists for the BAT exam: the USC Manual of Cross-Connection Control, AWWA M14 and WAC 246-290-490.

    WAC 246-290-490 (cross-connection control) (opens in a new tab)

  3. Schedule with PSI

    After L&I approves you, PSI emails you. Schedule online or at 855-746-8173.

    PSI: schedule Washington plumbing exams (opens in a new tab)

  4. Pass and certify

    70% to pass. Pay your certificate fee within 90 days.

    Washington L&I: Plumber examination (opens in a new tab)

How to prepare

  • Know each assembly (air gap, AVB, PVB, SVB, DCVA, RPBA): what hazard and backflow type it protects against and where it may be installed.
  • Practice test procedures and gauge readings: RP relief valve opening point, check valve differentials and what a failed reading means.
  • Learn the troubleshooting patterns, such as a discharging relief valve or a fouled check, and Washington's annual testing rule.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

  • Manual of Cross-Connection Control, 10th edition (USC Foundation for Cross-Connection Control and Hydraulic Research)

    On Washington's BAT exam reference list; the backflow plumber exam is closed book, so study only.

Official reference list (as published by the testing agency)
  • USC Foundation for Cross-Connection Control and Hydraulic Research: Manual of Cross-Connection Control, 10th edition
  • EPA 816-R-03-002: Cross-Connection Control Manual
  • AWWA M14: Backflow Prevention and Cross-Connection Control
  • WAC 246-290-490 and WAC 246-292 (Washington cross-connection control and BAT rules)
  • Uniform Plumbing Code (UPC), 2015, Section 603 (cross-connection control)

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Cross-Connection Concepts and Degree of Hazard8
Backflow Regulations (WAC 246-290-490, WAC 246-292 and UPC 603)9
Backflow Assembly Types and Operation16
Installation and Location Requirements7
Field Testing and Troubleshooting12
Backflow Safety3

Exam day details

  • Administered by PSI, for the Washington State Department of Labor & Industries (L&I) Plumber Certification.
  • Fee: L&I's application and exam fee plus PSI's exam fee; PSI's bulletin prints only the three-part fee ($84) and the $52 retest portion fee.
  • One closed-book part: 55 questions, 90 minutes, 70% to pass.
  • L&I says the exam covers the safety, regulatory, operation and troubleshooting of backflow prevention assemblies. It names no study references; our references are the ones Washington lists for the BAT written exam.
  • The PL30 certificate covers maintenance and repair of backflow assemblies (cleaning and replacing internal parts) inside residential and commercial buildings. Installing or replacing an assembly needs a journey level or residential plumber (WAC 296-400A).
  • Apply to L&I first; approval is good for 1 year. 70% to pass. After a fail you reapply to L&I and wait 14 days. Pay your certificate fee within 90 days of passing.
  • L&I describes the exam's subject areas but not how many questions come from each; our topic weights are estimates.

Frequently asked questions

What's on the Washington backflow specialty plumber exam?

55 questions on backflow prevention assemblies. Our estimated split: Cross-Connection Concepts and Degree of Hazard 8; Backflow Regulations (WAC 246-290-490, WAC 246-292 and UPC 603) 9; Backflow Assembly Types and Operation 16; Installation and Location Requirements 7; Field Testing and Troubleshooting 12; Backflow Safety 3.

Do I need a BAT certificate for the backflow specialty?

Yes. The PL30 backflow specialty plumber certificate is for certified backflow assembly testers. The Department of Health certifies testers (WAC 246-292); L&I certifies the plumber specialty.

Is the Washington backflow exam open book?

No. It is closed book, 55 questions in 90 minutes, 70% to pass.

Free questions with answers

Show all 10 free questions and answers
  1. A building has a storage tank on its roof whose water surface is 46 feet above a service-level backflow assembly. About how much backpressure does that water column exert on the assembly's downstream side? (Use 0.433 psi per foot of water.)

    Answer: About 19.9 psi

    Each foot of water column exerts 0.433 psi, so 46 ft x 0.433 psi/ft = 19.9 psi. The 106 psi choice comes from multiplying by 2.31 (the feet-per-psi factor) instead of 0.433, and 10.6 psi is a decimal-place slip. Elevated piping or tanks are a classic source of backpressure (gravity) backflow.

    Reference: USC FCCCHR Manual of Cross-Connection Control, 10th edition, Backflow hydraulics: pressure of a water column (0.433 psi per foot)

  2. Who is responsible under WAC 246-290-490 for cross-connection control inside a consumer's premises (within the property lines)?

    Answer: The authority having jurisdiction under chapter 19.27 RCW

    WAC 246-290-490(1)(e) states purveyors are not responsible for eliminating or controlling cross-connections within the consumer's water system; under chapter 19.27 RCW that responsibility lies with the authority having jurisdiction (the local building or plumbing official). The purveyor's job is to protect the public system through premises isolation.

    Reference: WAC 246-290-490, (1)(e)

  3. Which situation can cause backsiphonage at an upper-floor outlet of a building even though the street pressure is normal?

    Answer: Heavy demand on lower floors pulling the riser below atmospheric up top

    When a large demand on lower floors (or an undersized riser) drops the pressure at higher outlets below atmospheric, water can be siphoned back from submerged outlets on upper floors: backsiphonage inside the building. A booster pump, thermal expansion and a pressurized boiler all raise pressure, which is backpressure, not backsiphonage.

    Reference: USC FCCCHR Manual of Cross-Connection Control, 10th edition, Causes of backsiphonage: reduced supply pressure within a building

  4. A wastewater treatment plant is a severe health hazard under WAC 246-290-490. Which premises isolation meets the rule?

    Answer: An air gap, or an RPBA at the service plus an in-plant air gap

    For severe hazards (wastewater treatment plants, radioactive material processing, nuclear reactors), WAC 246-290-490(4)(b)(ii) requires either an approved air gap for premises isolation or an approved RPBA/RPDA combined with an in-plant approved air gap. An RPBA alone, or two RPBAs in series, does not meet the rule.

    Reference: WAC 246-290-490, (4)(b)(ii)

  5. Under the UPC, a reduced-pressure principle backflow prevention assembly consists of two independently acting internally loaded check valves, two isolation valves, four test cocks, and what else?

    Answer: A differential pressure-relief valve between the checks

    UPC 603.3.7 describes the RP as two independently acting internally loaded check valves, a differential pressure-relief valve, four properly located test cocks and two isolation valves. The loaded air inlet belongs to a PVB, and the bypass meter belongs to a detector assembly.

    Reference: 2015 Uniform Plumbing Code, Section 603.3.7

  6. On a pressure vacuum breaker assembly, what are the two working parts between the shutoff valves?

    Answer: An internally loaded check valve and a loaded air inlet valve

    UPC 603.3.5 describes the PVB as a loaded air inlet valve, an internally loaded check valve, two properly located test cocks and two isolation valves. A float checking member with an atmospheric port is an AVB, and two checks with a relief valve make up an RP.

    Reference: 2015 Uniform Plumbing Code, Section 603.3.5

  7. A backflow assembly is installed with its lowest point 6 feet above the floor. What does UPC 603.4.3 require?

    Answer: A permanent platform able to support a tester

    UPC 603.4.3 requires a permanent platform capable of supporting a tester or maintenance person where an installation is elevated more than 5 feet above the floor or grade. A stored ladder or test cock extensions do not satisfy the rule.

    Reference: 2015 Uniform Plumbing Code, Section 603.4.3

  8. During a field test of a double check valve assembly, what minimum differential must each check valve hold to pass?

    Answer: 1.0 psid

    The USC field test criterion for each check of a double check valve assembly is a tight check holding at least 1.0 psid. 2.0 psid is the RP relief valve minimum, and 5.0 psid is the RP first-check minimum, not the DC standard.

    Reference: USC FCCCHR Manual of Cross-Connection Control, 10th edition, Field test procedure: double check valve assembly

  9. A tester finds the air inlet of a PVB opens when the differential drops to 0.7 psid. What is the result?

    Answer: Fail, it must open at 1.0 psid or more

    The USC criterion for the PVB air inlet is that it must open at not less than 1.0 psid (and open fully). Opening at 0.7 psid fails regardless of the check reading; each component is judged on its own criterion. The check valve must separately hold at least 1.0 psid.

    Reference: USC FCCCHR Manual of Cross-Connection Control, 10th edition, Field test procedure: pressure vacuum breaker assembly

  10. A plant room where a backflow assembly is planned contains toxic and corrosive chemical fumes from open process tanks. What does UPC 603.4.9 say?

    Answer: Backflow preventers must not be located there

    UPC 603.4.9 prohibits locating backflow preventers in an area containing fumes that are toxic, poisonous or corrosive, and also bars devices with atmospheric vents or ports from pits, underground or submerged locations. Fumes can enter vents and damage parts, and they endanger the person testing the assembly.

    Reference: 2015 Uniform Plumbing Code, Section 603.4.9