Washington licensing exam

Washington Journey Level Plumber Exam: Practice Test & Licensing Guide

Washington's journey level plumber exam, three closed-book parts: 100 code and trade questions from the 2015 UPC with Washington amendments, plus 25-item waste and vent and 25-item water sizing drawing exercises. 70% on each part.

Questions
150
Time limit
4.5 hours
Passing score
70% per part
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Administration and Definitions

Which term describes a drain pipe that conveys only liquid waste that is free of fecal matter?

Requirements at a glance

AgencyWashington State Department of Labor & Industries (L&I) Plumber Certification; exams by PSI
ExamCode and trade knowledge: 100 questions. Waste and vent drawings: 25 items. Water sizing drawings: 25 items. 90 minutes each, 70% on each, closed book
Books allowedNone: closed book. PSI provides UPC Tables 702.1, 610.3, 610.4 and 610.10 (not Table 703.2)
FeesL&I application $202.10 (paid again after a fail); PSI $84 for the three parts, $52 per retest portion.
TimingApproval is good for 1 year. Wait 14 days after a fail. Pay the certificate fee within 90 days of passing.

Plumber trainees applying to L&I for the journey level plumber certificate (4 years under a journey level plumber, or an approved school or military course).

How to get licensed, step by step

  1. Apply to L&I

    Send L&I your plumber certification application and the $202.10 fee with proof of experience. L&I approves you and PSI emails you.

    Washington L&I: Plumber examination (opens in a new tab)

  2. Study the 2015 UPC

    The exam is on the 2015 UPC with Washington amendments, even though job sites use the 2021 UPC. It is closed book, so learn the sizing tables, especially Table 703.2.

    PSI Washington Plumbing Candidate Information Bulletin (opens in a new tab)

  3. Schedule with PSI

    Pay PSI $84 and schedule all three parts.

    PSI: schedule Washington plumbing exams (opens in a new tab)

  4. Pass all three parts

    70% on each part. Then pay your certificate fee within 90 days.

    Washington L&I: Plumber examination (opens in a new tab)

How to prepare

  • Memorize UPC Table 703.2 (drainage and vent pipe loading and length): it is not handed out.
  • For the drawing parts, practice adding drainage fixture units and water supply fixture units and picking the minimum size, keeping aggregate vent area.
  • Know trap arm lengths (Table 1002.2), cleanouts, vent terminals, and water heater relief and venting rules.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

  • Uniform Plumbing Code (UPC), 2015 (IAPMO), with Washington State amendmentsEssential

    Study copy only: the plumber exam is closed book. WABO sells the 2015 UPC with Washington amendments.

    WABO (opens in a new tab)

Official reference list (as published by the testing agency)
  • Uniform Plumbing Code (UPC), 2015 (IAPMO), with Washington State amendments (closed book: study only)
  • UPC Tables 702.1, 610.3, 610.4 and 610.10 (provided at the exam)

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Journey Level Code and General Trade Knowledge(100 items, 100 scored · 90 min)
Administration and Definitions6
General Regulations12
Plumbing Fixtures and Fixture Fittings12
Water Heaters9
Water Supply and Distribution15
Sanitary Drainage15
Indirect Wastes6
Vents12
Traps and Interceptors9
Alternate Water Sources and Rainwater Catchment4
Waste and Vent Journey Level Drawings(25 items, 25 scored · 90 min)
Waste and Vent Sizing (Drawings)25
Water Sizing Journey Level Drawings(25 items, 25 scored · 90 min)
Water Pipe Sizing (Drawings)25

The parts are timed and scored separately, and you must pass each one. Our simulations score each part the same way and give you the combined time (270 minutes).

Exam day details

  • Administered by PSI, for the Washington State Department of Labor & Industries (L&I) Plumber Certification.
  • Fee: $84 to PSI for the three-part exam ($52 per retest portion), plus L&I's nonrefundable $202.10 application and exam fee, which you pay again after a fail.
  • Three parts, 90 minutes each: code and general trade knowledge (100 questions, UPC Chapters 1-10, 15, 16 and 17 with amendments), waste and vent drawings (25 items, Chapter 7) and water sizing drawings (25 items, Chapter 6). 70% to pass each.
  • Closed book. PSI provides UPC Tables 702.1, 610.3, 610.4 and 610.10 with the exam; Table 703.2 (maximum loading and length of drainage and vent piping) is not provided, so learn it.
  • The exam is based on the 2015 Uniform Plumbing Code with Washington State Building Code Council amendments, even though Washington now enforces the 2021 UPC (WAC 51-56). Study the 2015 edition.
  • The drawing parts show a building's fixtures and piping; you give fixture units and minimum pipe sizes (keeping aggregate venting). Our practice turns them into sizing questions.
  • Apply to L&I first; approval is good for 1 year. You must pass all 3 parts (70% each). After a fail you reapply to L&I, pay again and wait 14 days; L&I decides whether a part you passed is waived. Pay your certificate fee within 90 days of passing.
  • L&I lists the UPC chapters but not how many questions come from each; our topic weights are estimates.

Frequently asked questions

What's on the Washington journey level plumber exam?

Three parts. Code and general trade knowledge, 100 questions from UPC Chapters 1-10, 15, 16 and 17 with Washington amendments (our estimated split: Administration and Definitions 6; General Regulations 12; Plumbing Fixtures and Fixture Fittings 12; Water Heaters 9; Water Supply and Distribution 15; Sanitary Drainage 15; Indirect Wastes 6; Vents 12; Traps and Interceptors 9; Alternate Water Sources and Rainwater Catchment 4). Waste and vent drawings, 25 items from Chapter 7. Water sizing drawings, 25 items from Chapter 6.

Which UPC edition is the Washington plumber exam on?

The 2015 Uniform Plumbing Code with Washington amendments, per L&I and PSI. Washington enforces the 2021 UPC on job sites, but the exam has not changed editions. The exam is closed book; PSI hands out Tables 702.1, 610.3, 610.4 and 610.10.

Is the Washington plumber exam open book?

No. The journey level and residential exams are closed book. PSI provides Tables 702.1, 610.3, 610.4 and 610.10; Table 703.2 is not provided.

Does Washington accept other states' plumber licenses?

Washington has reciprocity with Idaho for journey level plumbers. Other out-of-state plumbers must pass the Washington exam; a one-time 120-day temporary permit ($100.30) is available while you wait to test.

Free questions with answers

Show all 10 free questions and answers
  1. Which term describes a drain pipe that conveys only liquid waste that is free of fecal matter?

    Answer: Waste pipe

    The UPC definition of a waste pipe is a pipe that conveys only liquid waste free of fecal matter. A soil pipe carries the discharge of water closets, urinals and similar fixtures, so it carries fecal matter. A vent stack carries air, not liquid, and a building sewer is the outside piping beyond the building drain.

    Reference: 2015 Uniform Plumbing Code, Chapter 2, Definitions (Waste Pipe)

  2. Horizontal copper tube 1-1/2 inches and smaller must be supported at intervals not exceeding:

    Answer: 6 feet

    Table 313.3 sets copper and copper alloy tube at 6 feet horizontally for sizes 1-1/2 inches and smaller, and 10 feet for 2 inches and larger. Vertical copper is supported at each floor, not to exceed 10 feet.

    Reference: 2015 Uniform Plumbing Code, Table 313.3

  3. What is the minimum distance from the center of a water closet to a side wall or obstruction?

    Answer: 15 inches

    Section 402.5 requires a water closet or bidet to be set no closer than 15 inches from its center to a side wall or obstruction, and no closer than 30 inches center to center from a similar fixture. The clear space in front must be at least 24 inches. The 12 inch figure is the urinal dimension.

    Reference: 2015 Uniform Plumbing Code, Section 402.5

  4. The Btu/h discharge capacity of a temperature and pressure relief device on a water heater must be:

    Answer: not less than the input rating of the water heater

    Section 504.6 requires the hourly Btu discharge capacity (or the rated steam relief capacity) of the relief device to be not less than the input rating of the water heater. A smaller device could not relieve the heat the heater can add if the thermostat fails.

    Reference: 2015 Uniform Plumbing Code, Section 504.6

  5. A building water system has a pressure regulator and a backflow preventer on the service. To handle thermal expansion, an approved expansion tank must be installed:

    Answer: in the cold water piping on the building side of the regulator or backflow device

    Sections 608.2 and 608.3 require an approved expansion tank (or similar device) on the building side of a check valve, backflow preventer or regulator that prevents building pressure from dissipating back to the main. Without it, thermal expansion raises pressure with nowhere to go.

    Reference: 2015 Uniform Plumbing Code, Sections 608.2 and 608.3

  6. A double sanitary tee may be used on a stack only if the barrel of the fitting is:

    Answer: at least two pipe sizes larger than the largest inlet

    Section 706.2 permits double sanitary tees where the barrel is not less than two pipe sizes larger than the largest inlet, and prohibits fittings with more than one inlet at the same level unless the discharge from one inlet cannot readily enter another.

    Reference: 2015 Uniform Plumbing Code, Section 706.2

  7. What is the minimum size of an individual vent connected to a 4-inch horizontal drain?

    Answer: 2 inches

    Section 904.1 says an individual vent may not be smaller than 1-1/4 inches nor smaller than one-half the diameter of the drain it serves. Half of 4 inches is 2 inches, which is larger than the 1-1/4 inch floor, so 2 inches governs (Table 703.2 must also be satisfied for the units and length).

    Reference: 2015 Uniform Plumbing Code, Section 904.1

  8. What is the maximum length of a fixture tailpiece measured from the fixture outlet to the trap?

    Answer: 24 inches

    Section 1001.2 says the vertical distance between a fixture outlet and the trap weir must be as short as practicable and the tailpiece may in no case exceed 24 inches. A longer tailpiece weakens the self-scouring action and invites siphonage.

    Reference: 2015 Uniform Plumbing Code, Section 1001.2

  9. A public restroom has 4 water closets (1.6 gpf), 4 lavatories, 2 urinals with integral traps (1.0 gpf), 1 service/mop basin and 1 floor drain. Using public-use values in Table 702.1, what is the total DFU load?

    Answer: 29 DFU

    Public values: water closets 4 x 4 = 16, lavatories 4 x 1 = 4, urinals 2 x 2 = 4, service basin 3, floor drain 2. 16 + 4 + 4 + 3 + 2 = 29 DFU. Using the private water closet value of 3 gives 25 (12 + 4 + 4 + 3 + 2).

    Reference: 2015 Uniform Plumbing Code, Table 702.1

  10. A private bathroom has a 1.6 gpf gravity-tank water closet, a lavatory and a combination bath/shower. Using Table 610.3, what is the total water supply fixture unit (WSFU) load of the bathroom?

    Answer: 7.5 WSFU

    Table 610.3 (private): gravity-tank water closet 1.6 gpf = 2.5 WSFU, lavatory = 1.0, bathtub or combination bath/shower = 4.0. 2.5 + 1.0 + 4.0 = 7.5 WSFU. Using 3.0 for the water closet (the value for greater than 1.6 gpf) would give 8.0.

    Reference: 2015 Uniform Plumbing Code, Table 610.3