Question 1 of 10Washington Laws and Rules (RCW 19.28 and WAC 296-46B)

A residential (02) specialty electrician wants to take the master specialty electrician examination for the residential specialty. What does RCW 19.28.191(1)(b) require?

Requirements at a glance

AgencyWashington State Department of Labor & Industries (L&I) Electrical Program; exams by PSI
ExamNEC and Theory: 80 questions, 4 hours. WA Codes: 20 questions, 1 hour. Major Load Calculations: 10 questions, 2 hours. 70% on each, open book
Books allowed2020 NEC, printed RCW 19.28 and WAC 296-46B in a three-ring binder, and any original copyrighted reference (Ugly's, Ferm's). Permanent tabs only, no handwritten notes
FeesPSI fees are on the exam details above; L&I application and certificate fees are separate.
TimingPass all sections within 1 year. Wait 14 days after a fail; after 3 fails of a section, 3 months.

Journey level electricians who have held a Washington 01 journey level certificate for 4 years (RCW 19.28.191) and want the master certificate, which lets an electrical contractor designate them to supervise electrical work.

How to get licensed, step by step

  1. Get approved (or register)

    Apply to L&I once you have held your 01 journey level certificate for 4 years. L&I's eligibility notice gives you the Exam Unique ID you use to register with PSI.

    Washington L&I: Electrical exam information (opens in a new tab)

  2. Print the law and get your books

    Print RCW 19.28 and WAC 296-46B, hole-punch them into a three-ring binder and tab them. Bring a 2020 NEC (not 2023) and any copyrighted references you like.

    Chapter 19.28 RCW (electricians and electrical installations) (opens in a new tab)Chapter 296-46B WAC (electrical safety standards and certification) (opens in a new tab)

  3. Schedule with PSI

    Schedule online or at 855-834-8751. Book all sections of your exam for the same day.

    PSI: schedule Washington electrical exams (opens in a new tab)PSI Washington Electrical Candidate Information Bulletin (opens in a new tab)

  4. Pass every section

    70% on each section; you retest only the sections you fail. Your score appears on screen right away.

    PSI Washington Electrical Candidate Information Bulletin (opens in a new tab)

How to prepare

  • Washington's exam tests the 2020 NEC, not the 2023 NEC used on job sites. Study and tab a 2020 code book.
  • The master WA Codes section is 20 questions in 1 hour, scored on its own. Know contractor and administrator duties, supervision ratios, permits, inspections and civil penalties in WAC 296-46B and RCW 19.28.
  • Wiring methods (11), theory (12), overcurrent protection (7) and grounding (7) lead the NEC section. Practice Article 220 dwelling and commercial load calculations for the 10-question calc section.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC and RCW 19.28 and WAC 296-46B. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC), 2020 EditionEssential

    Washington's exam uses the 2020 edition, not the 2023 NEC enforced on job sites. Permanent tabs only.

    NFPA store (opens in a new tab)

  • Chapter 19.28 RCW and Chapter 296-46B WAC (Washington electrical law and rules)Essential

    Print them free and bring them hole-punched in a three-ring binder; every exam has a WA Codes section (17 questions, 20 for master).

    WAC 296-46B (Washington Legislature) (opens in a new tab)

  • Ugly's Electrical References (or another copyrighted quick reference)

    Any original copyrighted reference is allowed in the room; handy for theory and formulas.

Official reference list (as published by the testing agency)
  • NFPA 70: National Electrical Code (NEC), 2020 edition
  • Chapter 19.28 RCW (Washington electrical law), current version
  • Chapter 296-46B WAC (Washington electrical rules), current version
  • Any original copyrighted electrical reference, e.g. Ugly's Electrical References or Ferm's Fast Finder (allowed in the exam room)

What's on the exam

Official content outline from PSI, (number of questions per topic):

TopicQuestions
NEC and Theory(80 items, 80 scored · 240 min)
Article 90: Introduction2
Articles 100-110: General Requirements4
Articles 200-225, 280-285: Wiring and Protection3
Article 230: Services5
Article 240: Overcurrent Protection7
Article 250: Grounding and Bonding7
Articles 300-398: Wiring Methods11
Articles 400-427, 455-480: Electrical Equipment4
Articles 430-450: Motors, HVAC, Generators and Transformers5
Article 490: Equipment Over 1000 Volts1
Articles 500-516: Hazardous Locations4
Articles 517-590: Special Occupancies5
Articles 600-695: Special Equipment4
Articles 700-702: Emergency and Standby Systems3
Articles 705-780: Special Conditions2
Articles 800-830: Communications Systems1
General Trade Knowledge and Theory12
WA Codes(20 items, 20 scored · 60 min)
Washington Laws and Rules (RCW 19.28 and WAC 296-46B)20
Major Load Calculations(10 items, 10 scored · 120 min)
Major Load Calculations (Article 220)10

The parts are timed and scored separately, and you must pass each one. Our simulations score each part the same way and give you the combined time (420 minutes).

Exam day details

  • Administered by PSI, for the Washington State Department of Labor & Industries (L&I) Electrical Program.
  • Fee: PSI bills the master electrician exam at a flat rate, whatever the number of sections or time used; retests within a year are billed by the hour. L&I's application fee is separate.
  • Three sections: NEC and Theory (80 questions, 4 hours), WA Codes (20 questions, 1 hour) and Major Load Calculations (10 questions, 2 hours). 70% to pass each.
  • Open book. Bring the 2020 NEC, printed copies of RCW 19.28 and WAC 296-46B in a three-ring binder, and any original copyrighted reference (Ugly's, Ferm's and so on). Highlighting, underlining and permanent tabs only: no handwritten notes, sticky notes or removable tabs. A silent, nonprogrammable calculator is allowed.
  • The exam is based on the 2020 NEC, even though Washington has enforced the 2023 NEC on job sites since April 1, 2024 (and adopts the 2026 NEC on December 31, 2026). Rules that changed in 2023 can give a wrong answer here.
  • Get L&I approval first: you need 4 years as a certified 01 journey level electrician. L&I's eligibility notice gives you the Exam Unique ID you use to register with PSI. You have 1 year from approval to pass all sections.
  • 70% on each section. Passed sections carry over: you retest only the sections you failed, within 1 year of your first attempt. Wait 14 days after a fail; after 3 fails of a section, wait 3 months between attempts.
  • Up to 10 unscored experimental questions may be added; their time does not count against you.

Frequently asked questions

What's on the Washington master electrician exam?

PSI's 01 master outline. NEC and Theory, 80 questions: Article 90: Introduction 2; Articles 100-110: General Requirements 4; Articles 200-225, 280-285: Wiring and Protection 3; Article 230: Services 5; Article 240: Overcurrent Protection 7; Article 250: Grounding and Bonding 7; Articles 300-398: Wiring Methods 11; Articles 400-427, 455-480: Electrical Equipment 4; Articles 430-450: Motors, HVAC, Generators and Transformers 5; Article 490: Equipment Over 1000 Volts 1; Articles 500-516: Hazardous Locations 4; Articles 517-590: Special Occupancies 5; Articles 600-695: Special Equipment 4; Articles 700-702: Emergency and Standby Systems 3; Articles 705-780: Special Conditions 2; Articles 800-830: Communications Systems 1; General Trade Knowledge and Theory 12. WA Codes: 20 questions on RCW 19.28 and WAC 296-46B. Major Load Calculations: 10 questions.

Who can take the Washington master electrician exam?

Electricians who have held a valid Washington 01 journey level electrician certificate for 4 years (RCW 19.28.191). A master can be designated by an electrical contractor to supervise its electrical work, as an administrator can.

Which NEC edition is the Washington electrical exam on?

The 2020 NEC, plus the current RCW 19.28 and WAC 296-46B. PSI's bulletin and L&I's exam page both say 2020, even though Washington enforces the 2023 NEC on job sites. Bring a 2020 NEC.

Free questions with answers

Show all 10 free questions and answers
  1. A residential (02) specialty electrician wants to take the master specialty electrician examination for the residential specialty. What does RCW 19.28.191(1)(b) require?

    Answer: Two years holding a valid specialty certificate in that specialty

    For a master specialty electrician exam, RCW 19.28.191(1)(b) requires a valid specialty electrician certificate of competency in the specialty applied for, held for two years. Four years of journey level certification is the master journey level requirement in (1)(a). 4,000 hours is the experience needed to become a residential specialty electrician in the first place.

    Reference: Revised Code of Washington (RCW) chapter 19.28, RCW 19.28.191(1)(b)

  2. Under the Article 100 definition, a continuous load is one where the maximum current is expected to continue for how long?

    Answer: Three hours or more

    Article 100 defines a continuous load as a load where the maximum current is expected to continue for 3 hours or more. Continuous loads are what trigger the 125 percent sizing of branch circuits, feeders and services (210.19(A), 215.2(A), 230.42(A)).

    Reference: NFPA 70, National Electrical Code, 2020, Article 100, Continuous Load

  3. A 120/240-volt service drop crosses a roof overhang to a service mast that goes through the roof. No more than 6 feet of the drop, and 4 feet horizontally, passes above the overhang. Under 230.24(A) Exception No. 3, what is the minimum clearance above the roof?

    Answer: 18 inches

    230.24(A) sets a general vertical clearance above the roof surface, but Exception No. 3 allows 18 in. above only the overhanging portion where the voltage between conductors is 300 volts or less, not more than 6 ft of service-drop conductors (4 ft horizontally) pass above the roof overhang, and they terminate at a through-the-roof raceway or approved support. The 3 ft figure is Exception No. 2, for roofs sloped 4 in 12 or steeper, and 10 ft is a ground clearance from 230.24(B).

    Reference: NFPA 70, National Electrical Code, 2020, 230.24(A) Exception No. 3

  4. A feeder is protected by a 1,000-ampere circuit breaker. Under 240.4(C), what is the minimum ampacity of the feeder conductors?

    Answer: 1,000 amperes

    240.4(B) lets you round up to the next standard device only when the device is rated 800 A or less. Above 800 A, 240.4(C) requires the conductor ampacity to be equal to or greater than the rating of the overcurrent device, so the conductors need at least 1,000 A. The 125 percent factor applies to continuous loads, not to this rule.

    Reference: NFPA 70, National Electrical Code, 2020, 240.4(B), (C)

  5. Which method is NOT permitted by 250.8(A) for connecting an equipment grounding conductor to an enclosure?

    Answer: A sheet-metal screw

    250.8(A) lists permitted methods: listed pressure connectors, terminal bars, exothermic welding, machine screws engaging at least two threads or secured with a nut, thread-forming machine screws engaging at least two threads, and connections that are part of a listed assembly. Sheet-metal screws are specifically prohibited for connecting grounding conductors or connection devices to enclosures.

    Reference: NFPA 70, National Electrical Code, 2020, 250.8(A)

  6. A residential branch circuit of 120 volts, protected by a 20-ampere GFCI breaker, feeds a yard lamp post with direct-buried UF cable under a lawn. Using Table 300.5, what is the minimum cover?

    Answer: 12 inches

    Table 300.5, column 4 (residential branch circuits rated 120 volts or less with GFCI protection and overcurrent protection of 20 amperes maximum) allows 12 in. of cover under a lawn. Without that GFCI condition, direct-buried UF cable needs 24 in. (column 1). 18 in. is the column 3 value for rigid nonmetallic conduit.

    Reference: NFPA 70, National Electrical Code, 2020, Table 300.5

  7. A 150-kVA dry-type transformer with Class 130 insulation is installed indoors and is not completely enclosed. Under 450.21(B), how must it be installed?

    Answer: In a transformer room of fire-resistant construction with at least a 1-hour rating

    450.21(B) requires indoor dry-type transformers over 112-1/2 kVA to be installed in a transformer room of fire-resistant construction with a minimum 1-hour fire rating. The exceptions apply to transformers with Class 155 or higher insulation separated by a fire-resistant heat-insulating barrier or by distance, and to completely enclosed units. 3-hour vaults are for oil-insulated units (450.26).

    Reference: NFPA 70, National Electrical Code, 2020, 450.21(B)

  8. Under 517.16, where are isolated ground receptacles NOT permitted in a health care facility?

    Answer: In patient care vicinities

    517.16(A) prohibits isolated ground receptacles within a patient care vicinity, because they defeat the redundant grounding path that 517.13 requires there. They may be installed outside the patient care vicinity, such as offices and workshops, if the isolated EGC is installed per 517.16(B).

    Reference: NFPA 70, National Electrical Code, 2020, 517.16

  9. A series circuit has 6 ohms of resistance and 8 ohms of inductive reactance. What is its impedance?

    Answer: 10 ohms

    In a series RL circuit the resistance and reactance add as vectors: Z = square root of (R squared + XL squared) = square root of (36 + 64) = square root of 100 = 10 ohms. Adding them arithmetically gives 14 ohms, subtracting gives 2 ohms, and 4.8 ohms is the parallel combination (6 x 8 / 10).

    Reference: General electrical theory, Impedance of series RL circuit

  10. Standard method, 120/240-volt service: 1,500 sq ft dwelling, two small-appliance circuits, one laundry circuit, a 12-kW range, a 5.5-kW dryer, a 4.5-kW water heater, a 1.2-kW dishwasher, a 0.8-kW disposal, a 3.6-kVA air conditioner and a 5-kW electric furnace (noncoincident). What is the calculated load in amperes?

    Answer: 125.4 amperes

    Lighting 1,500 x 3 = 4,500 + 3,000 + 1,500 = 9,000 VA; Table 220.42: 3,000 + 6,000 x 0.35 = 5,100 VA. Range (Column C) 8,000 VA. Dryer 5,500 VA. Three appliances (4,500 + 1,200 + 800) = 6,500 VA at 100 percent (220.53 needs four). Heat 5,000 VA is larger than the 3,600-VA AC (220.60). Total = 5,100 + 8,000 + 5,500 + 6,500 + 5,000 = 30,100 VA; / 240 = 125.4 A.

    Reference: NFPA 70, National Electrical Code, 2020, 220.12; Table 220.42; 220.53; 220.54; Table 220.55; 220.60

Sources