Requirements at a glance
| Agency | Washington State Department of Labor & Industries (L&I) Electrical Program; exams by PSI |
|---|---|
| Exam | NEC and Theory: 60 questions, 3 hours. WA Codes: 17 questions, 1 hour. 70% on each, open book |
| Books allowed | 2020 NEC, printed RCW 19.28 and WAC 296-46B in a three-ring binder, and any original copyrighted reference (Ugly's, Ferm's). Permanent tabs only, no handwritten notes |
| Fees | PSI fees are on the exam details above; L&I application and certificate fees are separate. |
| Timing | Pass all sections within 1 year. Wait 14 days after a fail; after 3 fails of a section, 3 months. |
Electrical trainees applying to L&I for the 01 general journey level electrician certificate: 8,000 hours of supervised experience, at least 4,000 of them commercial or industrial.
Official links
- Washington L&I: Electrical exam information (opens in a new tab)
- PSI: schedule Washington electrical exams (opens in a new tab)
- PSI Washington Electrical Candidate Information Bulletin (opens in a new tab)
- Chapter 19.28 RCW (electricians and electrical installations) (opens in a new tab)
- Chapter 296-46B WAC (electrical safety standards and certification) (opens in a new tab)
How to get licensed, step by step
Get approved (or register)
Apply to L&I with your documented hours (8,000, at least 4,000 commercial or industrial). L&I's eligibility notice gives you the Exam Unique ID you use to register with PSI.
Washington L&I: Electrical exam information (opens in a new tab)
Print the law and get your books
Print RCW 19.28 and WAC 296-46B, hole-punch them into a three-ring binder and tab them. Bring a 2020 NEC (not 2023) and any copyrighted references you like.
Chapter 19.28 RCW (electricians and electrical installations) (opens in a new tab)Chapter 296-46B WAC (electrical safety standards and certification) (opens in a new tab)
Schedule with PSI
Schedule online or at 855-834-8751. Book all sections of your exam for the same day.
PSI: schedule Washington electrical exams (opens in a new tab)PSI Washington Electrical Candidate Information Bulletin (opens in a new tab)
Pass every section
70% on each section; you retest only the sections you fail. Your score appears on screen right away.
PSI Washington Electrical Candidate Information Bulletin (opens in a new tab)
How to prepare
- Washington's exam tests the 2020 NEC, not the 2023 NEC used on job sites. Study and tab a 2020 code book.
- The WA Codes section (17 questions, 1 hour) is scored on its own. Tab WAC 296-46B's certification, supervision and permit sections (the -900s) and know RCW 19.28's basics.
- Wiring methods (10), overcurrent protection (6), grounding and bonding (6) and theory (7) are the biggest NEC areas.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2020 NEC and RCW 19.28 and WAC 296-46B. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2020 EditionEssential
Washington's exam uses the 2020 edition, not the 2023 NEC enforced on job sites. Permanent tabs only.
Chapter 19.28 RCW and Chapter 296-46B WAC (Washington electrical law and rules)Essential
Print them free and bring them hole-punched in a three-ring binder; every exam has a WA Codes section (17 questions, 20 for master).
Ugly's Electrical References (or another copyrighted quick reference)
Any original copyrighted reference is allowed in the room; handy for theory and formulas.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2020 edition
- Chapter 19.28 RCW (Washington electrical law), current version
- Chapter 296-46B WAC (Washington electrical rules), current version
- Any original copyrighted electrical reference, e.g. Ugly's Electrical References or Ferm's Fast Finder (allowed in the exam room)
What's on the exam
Official content outline from PSI, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| NEC and Theory(60 items, 60 scored · 180 min) | ||
| Article 90: Introduction | 1 | |
| Articles 100-110: General Requirements | 3 | |
| Articles 200-225, 280-285: Wiring and Protection | 3 | |
| Article 230: Services | 4 | |
| Article 240: Overcurrent Protection | 6 | |
| Article 250: Grounding and Bonding | 6 | |
| Articles 300-398: Wiring Methods | 10 | |
| Articles 400-427, 455-480: Electrical Equipment | 3 | |
| Articles 430-450: Motors, HVAC, Generators and Transformers | 3 | |
| Article 490: Equipment Over 1000 Volts | 1 | |
| Articles 500-516: Hazardous Locations | 2 | |
| Articles 517-590: Special Occupancies | 4 | |
| Articles 600-695: Special Equipment | 3 | |
| Articles 700-702: Emergency and Standby Systems | 2 | |
| Articles 705-780: Special Conditions | 1 | |
| Articles 800-830: Communications Systems | 1 | |
| General Trade Knowledge and Theory | 7 | |
| WA Codes(17 items, 17 scored · 60 min) | ||
| Washington Laws and Rules (RCW 19.28 and WAC 296-46B) | 17 | |
The parts are timed and scored separately, and you must pass each one. Our simulations score each part the same way and give you the combined time (240 minutes).
Exam day details
- Administered by PSI, for the Washington State Department of Labor & Industries (L&I) Electrical Program.
- Fee: $75 to PSI for the 4-hour exam (PSI bills electrician exams by the hour ($45 for 1 hour up to $105 for 7 hours); retests are billed by the hour too). L&I's application fee is separate.
- Two sections: NEC and Theory (60 questions, 3 hours) and WA Codes (17 questions, 1 hour). 70% to pass each.
- Open book. Bring the 2020 NEC, printed copies of RCW 19.28 and WAC 296-46B in a three-ring binder, and any original copyrighted reference (Ugly's, Ferm's and so on). Highlighting, underlining and permanent tabs only: no handwritten notes, sticky notes or removable tabs. A silent, nonprogrammable calculator is allowed.
- The exam is based on the 2020 NEC, even though Washington has enforced the 2023 NEC on job sites since April 1, 2024 (and adopts the 2026 NEC on December 31, 2026). Rules that changed in 2023 can give a wrong answer here.
- Get L&I approval first: L&I sends an eligibility notice with the Exam Unique ID you use to register with PSI. You have 1 year from approval to pass all sections.
- 70% on each section. Passed sections carry over: you retest only the sections you failed, within 1 year of your first attempt. Wait 14 days after a fail; after 3 fails of a section, wait 3 months between attempts.
- Up to 10 unscored experimental questions may be added; their time does not count against you.
Frequently asked questions
What's on the Washington journeyman electrician exam?
PSI's 01 electrician outline. NEC and Theory, 60 questions: Article 90: Introduction 1; Articles 100-110: General Requirements 3; Articles 200-225, 280-285: Wiring and Protection 3; Article 230: Services 4; Article 240: Overcurrent Protection 6; Article 250: Grounding and Bonding 6; Articles 300-398: Wiring Methods 10; Articles 400-427, 455-480: Electrical Equipment 3; Articles 430-450: Motors, HVAC, Generators and Transformers 3; Article 490: Equipment Over 1000 Volts 1; Articles 500-516: Hazardous Locations 2; Articles 517-590: Special Occupancies 4; Articles 600-695: Special Equipment 3; Articles 700-702: Emergency and Standby Systems 2; Articles 705-780: Special Conditions 1; Articles 800-830: Communications Systems 1; General Trade Knowledge and Theory 7. WA Codes: 17 questions on RCW 19.28 and WAC 296-46B.
Which NEC edition is the Washington electrical exam on?
The 2020 NEC, plus the current RCW 19.28 and WAC 296-46B. PSI's bulletin and L&I's exam page both say 2020, even though Washington enforces the 2023 NEC on job sites. Bring a 2020 NEC.
Who gives the Washington electrical exams?
PSI, for the Washington State Department of Labor & Industries (L&I). Electrician candidates need L&I approval first and register with the Exam Unique ID on their eligibility notice. Administrator candidates register directly with PSI.
How many hours do I need for the Washington journeyman exam?
8,000 hours of supervised electrical experience, with at least 4,000 hours in commercial or industrial work (WAC 296-46B-940 and Table 945-1).
Free questions with answers
Show all 10 free questions and answers
Under RCW 19.28.161, how much of each working day must a certified electrician supervising a trainee be on the same jobsite as the trainee, unless the chapter provides otherwise?
Answer: At least 75 percent of the working day
RCW 19.28.161(3) requires supervision on the same jobsite and under the control of a certified electrician, who must be on that jobsite a minimum of seventy-five percent of each working day. Fifty and ninety percent are not the statutory figures, and the statute does not require 100 percent.
Reference: Chapter 19.28 RCW, RCW 19.28.161(3)
A 480Y/277-volt panelboard is installed in a mechanical room. Directly opposite its front is a grounded concrete block wall (exposed live parts on one side of the working space, grounded surface on the other). What is the minimum depth of working space in front of the panelboard?
Answer: 3 ft 6 in.
The panelboard is 277 volts to ground, so the 151 to 600 volt row of Table 110.26(A)(1) applies. Condition 2 (exposed live parts on one side and grounded parts, including concrete or block walls, on the other) requires 3 ft 6 in. Condition 1 (3 ft) applies when no live or grounded parts are opposite, and Condition 3 (4 ft) applies with exposed live parts on both sides. At 0 to 150 volts to ground (for example 208Y/120 V) every condition is 3 ft.
Reference: NFPA 70, National Electrical Code, 2020, Table 110.26(A)(1)
A branch circuit supplies 24 amperes of continuous load and 10 amperes of noncontinuous load. What is the minimum branch-circuit conductor ampacity before any adjustment or correction factors, under 210.19(A)(1)?
Answer: 40 amperes
Section 210.19(A)(1)(a) requires an ampacity not less than the noncontinuous load plus 125 percent of the continuous load: 24 x 1.25 = 30 A, plus 10 A = 40 A. Adding the loads (34 A) skips the 125 percent factor, and 24 x 1.25 alone (30 A) forgets the noncontinuous load.
Reference: NFPA 70, National Electrical Code, 2020, 210.19(A)(1)(a)
A small commercial building (not a dwelling) has more than two branch circuits. What is the minimum rating of its service disconnecting means under 230.79?
Answer: 60 amperes
Section 230.79 sets minimum service disconnect ratings: 15 A for installations of a single branch circuit (230.79(A)), 30 A for two 2-wire branch circuits (230.79(B)), 100 A 3-wire for a one-family dwelling (230.79(C)), and 60 A for all other installations (230.79(D)). A commercial building with more than two circuits falls under 230.79(D).
Reference: NFPA 70, National Electrical Code, 2020, 230.79(D)
A 10 ft feeder tap is made from a 400-ampere feeder under 240.21(B)(1). The field-installed tap conductors leave the enclosure where the tap is made. Apart from the load and terminating-device requirements, what is the lowest tap conductor ampacity the rule allows?
Answer: 40 amperes
Under 240.21(B)(1)(4), field-installed 10 ft tap conductors that leave the enclosure must have an ampacity of at least one-tenth of the rating of the overcurrent device protecting the feeder: 400 x 0.10 = 40 A. The tap must also carry the calculated load and be at least the rating of the device it terminates in. 133 A (one-third of 400 A) is the 25 ft tap value, and one-quarter (100 A) is not a Code ratio.
Reference: NFPA 70, National Electrical Code, 2020, 240.21(B)(1)(4)
A 4/0 AWG copper service-entrance conductor is grounded to a concrete-encased electrode (Ufer) in the building footing, and no other electrode is used. Under 250.66(B), what is the minimum size copper grounding electrode conductor required to connect to that electrode?
Answer: 4 AWG
Section 250.66(B) limits the grounding electrode conductor to 4 AWG copper when it is the sole connection to a concrete-encased electrode, regardless of the larger size Table 250.66 would require. Table 250.66 would give 2 AWG for 4/0 AWG copper service conductors, and 6 AWG is the limit for rod, pipe or plate electrodes.
Reference: NFPA 70, National Electrical Code, 2020, 250.66(B); Table 250.66
Type NM cable is run through bored holes in wood studs. What is the minimum distance from the edge of the stud to the nearest edge of the bored hole before a steel plate is required for protection, under 300.4(A)(1)?
Answer: 1-1/4 in.
Section 300.4(A)(1) requires cables or raceways through bored holes in wood framing members to be installed so that the edge of the hole is at least 1-1/4 in. from the nearest edge of the framing member. If it cannot be, a steel plate or sleeve at least 1/16 in. thick must protect the cable or raceway.
Reference: NFPA 70, National Electrical Code, 2020, 300.4(A)(1)
Under 400.12, which use of flexible cords and cables is NOT permitted?
Answer: As a substitute for the fixed wiring of a structure
Section 400.12 prohibits flexible cords and cables as a substitute for the fixed wiring of a structure, where run through holes in walls, ceilings or floors, doors, windows, or attached to building surfaces, and where concealed behind walls, ceilings or floors. Cords are acceptable for portable lamps and the appliance uses permitted elsewhere in the Code.
Reference: NFPA 70, National Electrical Code, 2020, 400.12(1)
How many receptacles must be provided at each patient bed location in a general care area of a hospital, and what must they be, under 517.18(B)?
Answer: At least eight, all listed hospital grade
Section 517.18(B) requires a minimum of eight receptacles at each patient bed location in a general care (Category 2) space, and they must be listed hospital grade and so identified (exceptions cover items such as psychiatric locations). Four was the requirement in older editions, and fourteen is the critical care (Category 1) minimum in 517.19(B). The 2023 NEC keeps eight.
Reference: NFPA 70, National Electrical Code, 2020, 517.18(B)
Resistors of 6, 12 and 12 ohms are connected in parallel. What is the equivalent resistance?
Answer: 3 ohms
For parallel resistors, 1/R = 1/6 + 1/12 + 1/12 = 4/12, so R = 3 ohms. The result is always smaller than the smallest branch. 30 ohms is the series total, 10 ohms is the average, and 4 ohms is the 6 and 12 pair alone without the third resistor.
Reference: General electrical theory, General electrical theory: parallel circuit resistance
Sources
- PSI: Washington Electrical Candidate Information Bulletin (10/30/2025) (opens in a new tab)
- Washington L&I: Electrical exam information (opens in a new tab)
Questions last verified November 3, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.