Requirements at a glance
| Agency | Tennessee Board for Licensing Contractors; exams by Prov |
|---|---|
| License | LMC masonry contractor (masonry work of $100,000 or more) |
| Exams | 70 questions, 3.5 hours, 73%, plus the Business and Law exam |
| Books allowed | 2021 IBC, 2018 IRC, Study Guide for Masonry Contractors (2nd ed.) and a repair and restoration reference |
| Fees | $53 per Prov exam attempt, plus the Board application ($250; renewal $200) |
Qualifying individuals for a Tennessee LMC license (masonry portion over $100,000) from the Board for Licensing Contractors.
Official links
How to get licensed, step by step
Apply to the Board
Send the Board your application. CMC and CMC-A applicants need pre-approval first (3 years of experience; $50 request). Trade-exam waivers exist for reciprocity states and NASCLA exams.
Board: how to get a contractor license (opens in a new tab)Tennessee Board for Licensing Contractors (opens in a new tab)
Schedule the Business and Law exam and the LMC exam with Prov
Register with Prov and test at a testing center or at home with Examroom. You can retake with no waiting period at $53 per attempt.
Schedule with Prov (Tennessee contractors) (opens in a new tab)Prov: register for your exam (opens in a new tab)
Pass at 73%
Every Tennessee contractor exam is open book and needs 73% to pass.
Schedule with Prov (Tennessee contractors) (opens in a new tab)
Get licensed
Send your results to the Board with the $250 application fee and your financial statement. Limits depend on working capital and net worth, and from July 1, 2026 a surety bond can replace the statement.
How to prepare
- Bring the editions on Prov's list: the 2017 NEC for electrical, the 2021 IPC, IMC and IFGC for plumbing and HVAC, the 2018 IRC for residential building and the 2021 IBC for commercial, industrial and mechanical. PSI-era books are accepted until 1/1/2027, then only Prov-recommended ones.
- Tab your books before exam day with permanent tabs only. You can highlight, but moveable tabs are not allowed, and only a simple 4-function calculator is permitted.
- Tennessee has no state journeyman or master license; cities and counties run their own cards and tests. These exams are for contractor classifications and the limited licenses (LLE and LLP).
- Safety (8), plan reading (7), concrete block (7) and brick (7) are the largest sections.
- Know mortar types, grout and reinforcement placement; with reinforced masonry they are 16 questions.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 IBC and the 2018 IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 International Building Code (IBC)Essential
Allowed in the exam room. Tennessee adopts it with amendments (Chapter 11 removed). The code behind the general code questions on the building exams.
ICC store (opens in a new tab)Tennessee codes (UpCodes) (opens in a new tab)
2018 International Residential Code (IRC), with Tennessee amendmentsEssential
Allowed in the exam room. The code behind the BC-A general code and building sections.
Official reference list (as published by the testing agency)
- International Building Code (IBC), 2021
- International Residential Code (IRC), 2018
- Study Guide for Masonry Contractors, 2nd Edition (2014)
- Masonry repair and restoration reference listed in the Prov bulletin
What's on the exam
Official content outline from Prov (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Plan Reading | 7 | |
| Concrete Block | 7 | |
| Brick | 7 | |
| Stone | 5 | |
| Glass Block | 6 | |
| Mortar | 6 | |
| Grout | 4 | |
| Reinforced Masonry | 6 | |
| Restoration and Cleaning | 4 | |
| Quality and Assurance | 6 | |
| Tools | 4 | |
| Safety | 8 |
Exam day details
- Administered by Prov for the Tennessee Board for Licensing Contractors.
- Fee: $53 per exam to Prov, for a first attempt or a retake. Board application and license fees are separate.
- 70 questions in 3.5 hours; 73% to pass.
- Tennessee requires a license for masonry work of $100,000 or more.
- Open book: bring your own copies of the listed references. You may highlight and add permanent tabs, but moveable tabs are not allowed. Only a simple 4-function calculator is permitted.
- Test at a Prov testing center or at home with Examroom (remote proctoring). All Tennessee contractor exams need 73% to pass.
- You may retake as many times as needed with no waiting period, at $53 per attempt. If you fail within 10 points of 73% you can request a review of your exam.
- Prov replaced PSI as the Tennessee vendor on 7/1/2026. Reference lists accept PSI-era books until 1/1/2027, then only Prov-recommended ones.
- Every new contractor takes the Business and Law exam plus a trade exam for the classification. Reciprocity or NASCLA exams can waive the trade exam.
Frequently asked questions
What's on the Tennessee LMC exam?
70 questions: safety 8, plan reading 7, concrete block 7, brick 7, glass block 6, mortar 6, reinforced masonry 6, quality and assurance 6, and smaller sections.
When is an LMC needed?
For masonry work of $100,000 or more.
Which codes are used?
The 2021 IBC and the 2018 IRC, with the masonry study guide and a repair and restoration book.
Free questions with answers
Show all 10 free questions and answers
Under the 2018 IRC, what type of mortar is required for masonry foundation walls built to the prescriptive foundation wall tables (R404.1.1 series)?
Answer: Type M or Type S
R606.2.8.1 requires Type M or S mortar for masonry foundation walls built to Tables R404.1.1(1) through R404.1.1(4). Type N is a tempting answer because it is common above grade, but it is not allowed for these below-grade walls.
Reference: 2018 International Residential Code, R606.2.8.1
Under the 2018 IRC, grout must be placed within how long after water is first added to the mix?
Answer: 1 1/2 hours
R606.3.5.1 requires grout to be placed before initial set and not more than 1 1/2 hours after water has been added. Grout is a plastic mix that can lose bond and flow if it sits longer.
Reference: 2018 International Residential Code, R606.3.5.1
A crew will lay a 14-foot-high masonry wall with scaffolding on one side. Under 29 CFR 1926.706, how long must the limited access zone be measured out from the wall on the unscaffolded side?
Answer: 18 feet
1926.706(a)(2) sets the limited access zone equal to the height of the wall plus four feet, running the full length of the wall: 14 + 4 = 18 feet. The zone is not just the wall height, and doubling the height has no basis in the rule.
Reference: 29 CFR 1926 (OSHA Construction), 1926.706(a)(2)
Under the general limitations of the 2021 IBC (setting aside the opening-protective exceptions), where may glass unit masonry NOT be used?
Answer: In fire barriers and party walls
Section 2110.1.1 says solid or hollow approved glass block shall not be used in fire walls, party walls, fire barriers, fire partitions or smoke barriers, or for load-bearing construction. It is permitted in unrated and nonbearing exterior and interior walls, with limited exceptions for opening protectives.
Reference: 2021 International Building Code, 2110.1.1
Epoxy-coated bars are to be lap spliced in a masonry wall designed by allowable stress design, and an uncoated lap would be 30 inches. What lap length does Section 2107.2.1 of the 2021 IBC require?
Answer: 45 inches
Section 2107.2.1 says that where epoxy-coated bars are used the lap length must be increased by 50 percent. 30 x 1.5 = 45 inches. A 20 percent increase gives 36 inches, and doubling gives 60 inches.
Reference: 2021 International Building Code, 2107.2.1
How must head and bed joints be mortared when laying hollow concrete masonry units under the 2018 IRC?
Answer: Filled solidly with mortar in from the face a distance not less than the face shell thickness
R606.3.2.2 requires head and bed joints of hollow units to be filled solidly with mortar for a distance in from the face not less than the thickness of the face shell (face-shell bedding). Full bedding of cross webs is required only where cells are to be grouted, as in R606.3.5.3.
Reference: 2018 International Residential Code, R606.3.2.2
Brick veneer ties are being laid with a vertical spacing of 24 inches. Under R703.8.4.1, each tie may support no more than 2.67 square feet of wall. What is the maximum horizontal tie spacing that satisfies the area limit?
Answer: 16 inches
Each tie may support 2.67 square feet = 2.67 x 144 = 384 square inches. At 24 inches vertical spacing, the horizontal spacing is 384 / 24 = 16 inches. The 32-inch figure is the horizontal maximum in R703.8.4.1, which cannot be reached at 24 inches vertical without exceeding the area limit, and 12 inches comes from the 2 square foot limit in higher seismic categories.
Reference: 2018 International Residential Code, R703.8.4.1
Anchored stone veneer units attached directly to masonry, concrete or stud construction under Section 1404.7 of the 2021 IBC may be no thicker than what?
Answer: 10 inches
Section 1404.7 covers anchored stone veneer units not exceeding 10 inches in thickness. Slab-type veneer under 1404.8 is limited to 2 inches in thickness, which is the usual wrong pick.
Reference: 2021 International Building Code, 1404.7
A wall on a plan drawn at 1/4 inch = 1 foot measures 7 3/4 inches on the drawing. What is the actual length?
Answer: 31 feet
At 1/4 inch = 1 foot, each inch represents 4 feet. 7.75 inches x 4 = 31 feet. Dividing by 4 instead of multiplying gives under 2 feet, and using 1/8 inch = 1 foot would give 62 feet.
Reference: General masonry practice, Reading an architectural scale
For which masonry is special inspection NOT required under Section 1705.4 of the 2021 IBC?
Answer: Masonry fireplaces and chimneys built in accordance with Sections 2111 and 2113
Section 1705.4 exempts masonry fireplaces, heaters and chimneys constructed under 2111, 2112 or 2113, masonry foundation walls built to the prescriptive tables of 1807.1.6.3, and empirically designed masonry, glass unit masonry or veneer in Risk Category I to III structures. Engineered structural masonry is not exempt.
Reference: 2021 International Building Code, 1705.4
Sources
- Prov: Tennessee Contractor Candidate Information Bulletin (TNCONT_CIB 2026.08.18) (opens in a new tab)
- Tennessee Board for Licensing Contractors: how to get a contractor license (opens in a new tab)
Questions last verified November 15, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.