Requirements at a glance
| Agency | South Carolina Department of Labor, Licensing and Regulation (LLR), Residential Builders Commission; exams by PSI |
|---|---|
| Experience | Residential builder: at least 1 year of experience under a licensed builder or equivalent approved by the Commission (S.C. Code 40-59-220). Licensed specialty contractors (HVAC, plumbing, electrical): 1 year of Commission-approved experience under the supervision of a licensee in the trade |
| Exams | Residential HVAC: 80 questions, 4 hours, 65%, plus Business Management and Law for Residential Builders |
| Books allowed | IMC and IFGC 2021 or 2024 (SC), ACCA Manual J, Modern Refrigeration and SMACNA duct standards |
| Fees | PSI exam fees ($78 for one portion, $98 for both with the builder exam), plus the Commission's application and license fees and a bond |
Applicants for a Residential Builders Commission residential HVAC specialty contractor license.
Official links
How to get licensed, step by step
Apply to the Commission
Apply to the Residential Builders Commission first. Eligibility is valid for 1 year.
SC Residential Builders Commission (LLR) (opens in a new tab)S.C. Code Title 40 Chapter 59 (residential builders) (opens in a new tab)
Schedule Business and Law and the residential HVAC exam with PSI
You must pass both portions within 12 months and get 3 attempts in that period. After three failures you wait twelve months.
Schedule with PSI (residential builders) (opens in a new tab)
Get licensed
After you pass both portions, send the Commission your results, the license fee and your bond. The residential builder bond is $15,000 (S.C. Code 40-59-220).
SC Residential Builders Commission (LLR) (opens in a new tab)
How to prepare
- Code editions are changing. From November 1, 2026 PSI accepts the 2021 or the 2024 South Carolina codes (ICC codes with state modifications) and the 2023 or the 2020 NEC. After July 1, 2027 only the 2024 codes and the 2023 NEC. Bring one edition you know well and expect questions that read the same in both.
- Tab your books before exam day: highlighting, underlining and permanent tabs are allowed, but sticky notes and writing during the exam are not.
- Ducts are 14 of 80 questions: duct sizing, insulation and installation from the IMC and Manual D/duct calculator methods.
- Fuel gas (5), LP gas (4) and fuel oil (2) are 11 questions: tab IFGC sizing tables and the oil burner text.
- Heating and cooling principles (6), load calculations (6) and A/C and heat pump equipment (6) fill out the largest topics.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the SC IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
International Mechanical Code (IMC), 2021 or 2024 edition with South Carolina modificationsEssential
On PSI's list. Ducts, ventilation, equipment, venting and piping for the air conditioning and residential HVAC exams.
ICC store (opens in a new tab)Read free (UpCodes) (opens in a new tab)
International Fuel Gas Code (IFGC), 2021 or 2024 edition with South Carolina modifications
On PSI's list. Gas piping sizing, venting, combustion air and appliance installation.
ICC store (opens in a new tab)Read free (UpCodes) (opens in a new tab)
Modern Refrigeration and Air Conditioning (Goodheart-Willcox)
On PSI's list (21st or 22nd Edition for air conditioning; 19th or 20th for residential HVAC). Refrigeration cycle, components, controls and piping.
Official reference list (as published by the testing agency)
- International Mechanical Code (IMC) and International Fuel Gas Code (IFGC), 2021 or 2024 edition with South Carolina modifications
- ACCA Manual J and a duct calculator
- Modern Refrigeration and Air Conditioning, 19th or 20th Edition; SMACNA HVAC Duct Construction Standards, 3rd Edition; Residential Oil Burners, 3rd Edition; 29 CFR Part 1926 (all on PSI's list)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Insulation | 3 | |
| Hangers and Supports | 3 | |
| Sound, Vibration & Seismic Control | 1 | |
| Heating and Cooling Principles | 6 | |
| Refrigerants | 4 | |
| Load Calculations | 6 | |
| Testing, Adjusting and Balancing | 1 | |
| Controls | 4 | |
| A/C and Heat Pump Equipment | 6 | |
| Furnaces and Heaters | 5 | |
| Chimneys, Flues and Vents | 3 | |
| Combustion Air | 3 | |
| Ducts | 14 | |
| Ventilation and Exhausts | 3 | |
| Safety | 2 | |
| Fuel Gas | 5 | |
| LP Gas | 4 | |
| Fuel Oil | 2 | |
| Piping | 5 |
Exam day details
- Administered by PSI Services for the South Carolina Department of Labor, Licensing and Regulation (Residential Builders Commission).
- Fee: $78 to PSI. Board application and license fees are separate.
- 80 scored questions plus 1 to 10 unscored experimental items (they count against your time) in 240 minutes; 52 correct (65%) to pass.
- Code editions: from November 1, 2026 PSI accepts the 2021 or 2024 South Carolina codes (NEC 2023 or 2020); after July 1, 2027 only the 2024 codes and the 2023 NEC. Our questions are written to be correct under both.
- Open book: bring the references on PSI's list. You may highlight, underline and add permanent tabs; sticky notes and removable tabs are not allowed.
- Apply to the Residential Builders Commission first. Eligibility is valid for 1 year and you get 3 attempts within 12 months; you must pass Business Management and Law and the trade portion within that 12 months.
- After three failures you wait twelve months from the last attempt before testing again.
Frequently asked questions
What's on the South Carolina residential HVAC exam?
80 scored questions, led by Ducts 14, heating and cooling principles 6, load calculations 6, a/c and heat pump equipment 6, furnaces and heaters 5, fuel gas 5, piping 5, refrigerants 4 and 11 smaller topics.
What is the largest topic on the residential HVAC exam?
Ducts, with 14 of 80 questions. Heating and cooling principles and load calculations are 6 each, and A/C and heat pump equipment is 6.
What is the passing score?
52 of 80 (65%). PSI notes the passing score may change as exam performance is evaluated.
Free questions with answers
Show all 10 free questions and answers
Under the IMC table of minimum sheet metal thickness for ducts in a single dwelling unit, what is the minimum thickness of a 14-inch round galvanized steel duct operating at 1/2-inch water gauge?
Answer: 0.013 inch
In Table 603.4 the 12-to-14-inch round row lists 0.013 inch galvanized at 1/2-inch water gauge. The 0.016 figure is the galvanized value for the same diameter at 1-inch water gauge. The 0.018 and 0.023 figures are aluminum values, not galvanized. The table gives the same values in the 2021 and 2024 editions.
Reference: International Mechanical Code (2021 and 2024, SC edition), Table 603.4
A gas furnace will be installed in an attic. What are the minimum passageway dimensions the IMC requires from the opening to the furnace?
Answer: 30 inches high by 22 inches wide
IMC 306.3 requires an attic passageway at least 30 inches high and 22 inches wide, no more than 20 feet long measured along the centerline, with continuous solid flooring at least 24 inches wide. A level service space of 30 inches by 30 inches is required at the front of the appliance. Where the passageway is 6 feet high and 22 inches wide for its whole length, it may be up to 50 feet.
Reference: International Mechanical Code (2021 and 2024, SC edition), Section 306.3
What is the minimum test duration for gas piping in a single-family dwelling?
Answer: 10 minutes
IFGC 406.4.2 sets duration at not less than 1/2 hour per 500 cubic feet of pipe volume, but not less than 10 minutes for a system under 10 cubic feet or a system in a single-family dwelling. The test need never exceed 24 hours.
Reference: International Fuel Gas Code (2021 and 2024, SC edition), Section 406.4.2
What is the maximum operating pressure for plastic pipe in an LP-gas piping system under the IFGC?
Answer: 30 psig
IFGC 404.17.1 allows plastic gas pipe outdoors underground only and limits operation to 100 psig for natural gas and 30 psig for LP-gas. It may not be used within or under any building or slab, with listed exceptions for anodeless risers and patio or driveway slabs.
Reference: International Fuel Gas Code (2021 and 2024, SC edition), Section 404.17.1
A hydronic heating system has a maximum design pressure of 30 psi. At what pressure must it be hydrostatically tested?
Answer: 100 psi
IMC 1208.1 requires hydrostatic testing at 1 1/2 times maximum design pressure, but not less than 100 psi, held at least 15 minutes. 1.5 x 30 = 45 psi, which is below the 100 psi floor. Compressed air testing is allowed only for PEX when all manufacturers permit it.
Reference: International Mechanical Code (2021 and 2024, SC edition), Section 1208.1
A cooling system is rated at 42,000 Btu/h of total capacity. How many tons of refrigeration is that?
Answer: 3.5 tons
One ton of cooling equals 12,000 Btu/h (the heat needed to melt a ton of ice in 24 hours). 42,000 / 12,000 = 3.5 tons. Dividing by 10,000 gives 4.2 and rounding to 3 or 4 loses the half ton.
Reference: HVAC fundamentals (general practice), Ton of refrigeration = 12,000 Btu/h
A technician recovers refrigerant from a window air conditioner (a small appliance) with a compressor that is running, using recovery equipment made after November 15, 1993. What percent of the refrigerant must be recovered?
Answer: 90 percent
40 CFR 82.156(b)(2) requires 90 percent recovery when the appliance's compressor is operating and 80 percent when it is not, using equipment made on or after November 15, 1993. Another option is to evacuate the appliance to 4 inches of mercury vacuum. The 80 percent figure applies to the non-operating compressor case.
Reference: 40 CFR Part 82, Subpart F, Section 82.156(b)
A 200 square foot exterior wall assembly has a total R-value of 13. The indoor design temperature is 70 degrees F and the outdoor design temperature is 30 degrees F. What is the conductive heat loss through the wall?
Answer: 615 Btu/h
Q = U x A x TD where U = 1/R. U = 1/13 = 0.0769, TD = 70 - 30 = 40. Q = 0.0769 x 200 x 40 = 615 Btu/h. Using R in place of U (multiplying instead of dividing) gives 104,000, and omitting the R factor gives 8,000.
Reference: Residential load calculation (general practice), Conduction heat loss, Q = A x TD / R
A control transformer is rated 40 VA with a 24-volt secondary. What is the maximum secondary current?
Answer: 1.67 amperes
Current = VA / volts = 40 / 24 = 1.67 amps. Dividing the other way gives 0.6, and a transformer should not be loaded past this rating or its secondary can burn out. Add up the thermostat, contactor and gas valve loads before selecting a transformer.
Reference: Electrical fundamentals (general practice), Transformer VA rating, I = VA / V
A TXV air conditioner has a liquid line temperature of 95 degrees F and a condenser saturation temperature of 105 degrees F from the high-side gauge. What is the subcooling?
Answer: 10 degrees F
Subcooling = condenser saturation temperature - liquid line temperature = 105 - 95 = 10 degrees F. Doubling the difference (20) or reporting a gauge or line reading itself (95) are setup mistakes. TXV systems are normally charged to the manufacturer's target subcooling.
Reference: Refrigeration service practice (general), Subcooling = condenser saturation temperature - liquid line temperature
Sources
- PSI: South Carolina Residential Builders Commission Candidate Information Bulletin (updated 11/1/2026) (opens in a new tab)
- South Carolina Residential Builders Commission (LLR) (opens in a new tab)
- South Carolina Code of Laws Title 40 Chapter 59 (residential builders) (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.