Oregon licensing exam

Oregon Limited Residential Electrician Exam: Practice Test & Licensing Guide

The Oregon Building Codes Division Limited Residential Electrician (LR) exam: 52 open-book questions in 3 hours on dwelling wiring under the NEC with Oregon amendments. 75% to pass.

Questions
52
Time limit
3 hours
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Oregon Electrical Laws and Rules (ORS 479, OAR Division 918)

Which project falls within the scope of work of a limited residential electrician under Oregon rules?

Requirements at a glance

AgencyOregon Building Codes Division (BCD); state-run paper exam
ExperienceApproved Oregon apprenticeship, or 288 classroom hours plus 4,000 hours of residential experience, or 8,000 hours of residential experience, both out of state
Exam52 questions, 3 hours, open book; 75% to pass
Books allowedOpen book: NEC with Oregon amendments, NEC Handbook, ORS 479, OAR Division 918 and the other references on BCD's list; silent non-programmable calculator
Fees$100 application fee (no separate exam fee)

Electricians applying to BCD for a limited residential (LR) license to wire one- and two-family or multifamily dwelling units up to three floors above grade, under a general supervising electrician.

How to get licensed, step by step

  1. Apply to BCD

    Send the application, proof of qualifying training and experience, a high school diploma or GED, and the fee. Choose your proctor site on the application.

    Oregon Building Codes Division: licensing (opens in a new tab)

  2. Get your Letter of Authorization

    BCD mails the letter when your application is approved. Call the proctor site on it to book; you must test within 60 days of the letter.

    BCD: license exams and locations (opens in a new tab)

  3. Take the exam

    Bring the letter, photo ID, your approved books, pencils and a silent, non-programmable calculator. 75% is the passing score.

    BCD: license exams and locations (opens in a new tab)

  4. Results and retakes

    BCD grades the exam and mails the result in about 2 weeks. After a failure, wait 30 days and send a license reapplication form.

    BCD: license exams and locations (opens in a new tab)

How to prepare

  • The 2026 Oregon Electrical Specialty Code (2026 NEC) took effect October 1, 2026. BCD does not say which edition its exams test, so our questions follow the currently adopted code. Check your Letter of Authorization and the BCD materials list before you buy books.
  • BCD publishes no outline or topic weights, so our topic split is an estimate. The exam is open book: tab your NEC with Oregon amendments, ORS 479 and OAR Division 918 and practice finding answers fast.
  • Allowed: tabs, highlighting, printed errata and short margin notes. Not allowed: practice tests, class notes, calculation examples or added pages.
  • An LR license covers one- and two-family or multifamily dwellings up to three floors above grade, under a general supervising electrician. Drill dwelling branch circuits, receptacle and GFCI rules and service calculations.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • NFPA 70: National Electrical Code (NEC) with Oregon amendments and errataEssential

    BCD's approved materials list names the NEC with Oregon amendments and errata but no edition. The 2026 Oregon Electrical Specialty Code (2026 NEC) took effect October 1, 2026.

    NFPA store (opens in a new tab)Free online access (opens in a new tab)

  • Ugly's Electrical References

    Allowed on BCD's list, with Ferm's Fast Finder and the Tom Henry or Briganti key-word indexes. Useful for formulas, conductor data and quick lookups.

Official reference list (as published by the testing agency)
  • NFPA 70 / National Electrical Code (NEC) with Oregon amendments and errata
  • NEC Handbook and errata
  • Oregon Revised Statutes (ORS) Chapter 479
  • Oregon Administrative Rules (OAR) Division 918
  • American Electrician's Handbook (Hartwell); Electrical Black Book (Rapp); Ugly's Electrical References; Ferm's Fast Finder Index; Tom Henry's Key Word Index; Briganti NEC and Oregon Electrical Code key-word indexes
  • A silent, non-printing, non-programmable calculator
  • Tabs, highlighting, printed errata and short margin notes are allowed. Practice tests, class notes, calculation examples and added pages are not. (BCD materials list, rev. September 2026)

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Oregon Electrical Laws and Rules (ORS 479, OAR Division 918)6
General Requirements, Definitions, Grounding and Bonding8
Dwelling Services, Feeders and Branch Circuits12
Wiring Methods and Materials10
Equipment and Devices6
Special Equipment and Conditions4
Electrical Theory and Calculations6

Exam day details

  • Administered by the Oregon Building Codes Division (state-run paper exam at a proctor site).
  • Fee: No separate exam fee: the license application fee covers it ($100 journeyman and limited residential, $50 limited energy Class A). Application fees are nonrefundable.
  • 52 questions, 3 hours, open book, 75% to pass (BCD license directory). BCD publishes no topic outline, so our topic split is an estimate.
  • BCD mails a Letter of Authorization when your application is approved. Call the proctor site named on it to book; you must test within 60 days of the letter. Bring the letter and photo ID.
  • Proctor sites are in Bend, Eugene, Hermiston, Klamath Falls, Ontario, Pendleton, Portland, Roseburg, Salem and White City. BCD grades the paper exam and mails the result in about 2 weeks; results are not given by phone.
  • The passing score for all BCD licensing exams is 75%. After a failed exam you wait 30 days and send a license reapplication form; the result includes a strength and weakness report.
  • Bring your own pencils and, if you use one, a silent, non-printing, non-programmable calculator. Scratch paper is provided.
  • Qualification (BCD form 440-2570I): an approved Oregon apprenticeship, or 288 classroom hours plus 4,000 hours of residential on-the-job experience, or 8,000 hours of residential experience, both obtained outside Oregon (the 300 percent rule applies).
  • The 2026 Oregon Electrical Specialty Code (2026 NEC) took effect October 1, 2026, replacing the 2023 code. BCD does not say which edition its exams test, so our questions follow the currently adopted 2026 code; where a section number changed, the explanation also gives the 2023 number.

Note: BCD publishes no content outline, topic weights or question-count breakdown for the electrical exams, so our topic split is an estimate. The question count and time come from the BCD license directory. Our 2026 section numbers and rules were checked against NFPA's published 2026 revision records and Oregon's amendment table rather than the printed code, and BCD does not state which code edition the exams test.

Frequently asked questions

What can a limited residential electrician do?

Make electrical installations on one- and two-family or multifamily dwelling units not exceeding three floors above grade, under the supervision, direction and control of a general supervising electrician.

What's on the exam?

BCD publishes no outline. Our questions lean on dwelling branch circuits, services, wiring methods, grounding and Oregon electrical law.

Which NEC edition is on the exam?

The 2026 Oregon Electrical Specialty Code (2026 NEC) took effect October 1, 2026. BCD does not say which edition the exam tests, so our questions follow the currently adopted code.

Free questions with answers

Show all 10 free questions and answers
  1. Which project falls within the scope of work of a limited residential electrician under Oregon rules?

    Answer: Wiring a new two-story duplex with one dwelling unit on each floor

    OAR 918-282-0180(1) limits the limited residential electrician to one- or two-family or multi-family dwelling units not exceeding three floors above grade. A two-story duplex fits. A four-story or eight-story building exceeds three floors, and a diner is a commercial occupancy.

    Reference: Oregon Administrative Rules, Chapter 918, OAR 918-282-0180(1)(a)

  2. Which duty is assigned to a signing general supervising electrician by OAR 918-282-0140?

    Answer: Signing all permits and ensuring all electrical installations meet minimum safety standards

    OAR 918-282-0140(2) requires the signing supervising electrician to sign all permits, ensure installations meet minimum safety standards, and ensure electricians hold the proper license for the work. The rule also bars acting as supervising electrician for more than one employer, and bars assenting to work outside an electrician's license.

    Reference: Oregon Administrative Rules, Chapter 918, OAR 918-282-0140(2)(a), (b), (f), (i)

  3. In a new dwelling, what is the minimum headroom of the working space about a service panel in a basement, assuming the panel is shorter than the minimum headroom?

    Answer: 6 ft 6 in.

    Section 110.26(A)(3) requires the working space to extend to a height of 6 1/2 ft or the height of the equipment, whichever is greater. A 6 ft ceiling does not comply. Only existing dwelling units with service equipment or panelboards of 200 amperes or less get relief (Exception No. 2), which is why the stem says new dwelling.

    Reference: NFPA 70, National Electrical Code, 2026, 110.26(A)(3)

  4. Which item may NOT be located in the dedicated electrical space directly above a panelboard in a dwelling garage, from the floor to 6 ft above the equipment or to the structural ceiling, whichever is lower?

    Answer: A foreign system such as a water pipe or drain line

    Section 110.26(E)(1)(a) dedicates the space equal to the width and depth of the equipment, from the floor to 6 ft above it or the structural ceiling, to the electrical installation: no piping, ducts, leak protection apparatus or other equipment foreign to the electrical installation. Raceways and electrical equipment of the installation are not foreign, and the exception allows suspended ceilings with removable panels.

    Reference: NFPA 70, National Electrical Code, 2026, 110.26(E)(1)(a) and (E)(1)(b)

  5. A 120/240-volt overhead service drop crosses a public street. What is the minimum vertical clearance over the street?

    Answer: 18 ft

    Section 230.24(B)(4) requires 18 ft over public streets, alleys, roads and parking areas subject to truck traffic. The 12 ft value is for residential property and driveways at not over 300 volts to ground, and 15 ft for those same areas above 300 volts; 22 1/2 ft is a swimming-pool clearance, not a street value.

    Reference: NFPA 70, National Electrical Code, 2026, 230.24(B)(4)

  6. Type NM cable is run along the side of floor joists in an unfinished basement of a dwelling. What are the support intervals under 334.30?

    Answer: Every 4 1/2 ft, and within 12 in. of each box entry

    Section 334.30 requires NM cable to be supported at intervals not exceeding 4 1/2 ft and within 12 in. of every cable entry into a box, cabinet or fitting. The 6 ft interval belongs to MC cable and the 10 ft and 3 ft values to EMT.

    Reference: NFPA 70, National Electrical Code, 2026, 334.30

  7. A 120-volt, 20-ampere residential branch circuit with GFCI protection is run to an outdoor post light using Type UF cable buried directly in the yard. What is the minimum cover?

    Answer: 12 in.

    Table 300.7(A) (Table 300.5(A) in the 2023 NEC), Column 4, allows 12 in. of cover for residential branch circuits rated 120 volts or less with GFCI protection and maximum overcurrent protection of 20 amperes. The 24 in. value is the Column 1 default for other direct-buried cables.

    Reference: NFPA 70, National Electrical Code, 2026, Table 300.7(A), Column 4

  8. A 20-ampere receptacle is installed on the exterior wall of a house in a location exposed to rain. What enclosure does 406.9(B)(1) require?

    Answer: One weatherproof whether or not the attachment plug is inserted

    Section 406.9(B)(1) requires 15- and 20-ampere, 125- and 250-volt receptacles in a wet location to have an enclosure that is weatherproof whether or not the attachment plug cap is inserted, which in practice is an extra-duty in-use cover. The closed-cover standard in 406.9(A) applies only to damp locations.

    Reference: NFPA 70, National Electrical Code, 2026, 406.9(A) and (B)(1)

  9. What is the minimum distance from the inside wall of a permanently installed pool to a receptacle that supplies the circulating pump motor, and what protection does it need?

    Answer: At least 6 ft, GFCI protected and of the grounding type

    Section 680.22(A)(2) requires receptacles for pool circulation and sanitation equipment to be at least 6 ft from the inside walls of the pool, grounding type, with GFCI protection. A distance of 3 ft would be too close, and AFCI protection is not a substitute for GFCI.

    Reference: NFPA 70, National Electrical Code, 2026, 680.22(A)(2)

  10. A 240-volt electric heating element has a resistance of 12 ohms. How much current does it draw?

    Answer: 20 amperes

    Ohm's law: I = E / R = 240 / 12 = 20 amperes. Multiplying (240 x 12 = 2,880) is the common mistake; 10 A comes from dividing by 24 instead of 12.

    Reference: NFPA 70, National Electrical Code, 2026, Ohm's law (I = E / R)

Sources

Questions last verified November 9, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.