Oregon licensing exam

Oregon Limited Building Maintenance Electrician Exam: Practice Test & Licensing Guide

The Oregon Building Codes Division Limited Building Maintenance Electrician (BME) exam: 28 open-book questions in 2 hours on basic electricity, devices, fixtures and the NEC with Oregon amendments. 75% to pass.

Questions
28
Time limit
2 hours
Passing score
75%
Books
Open book

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Oregon Laws and BME Scope (OAR 918-282-0260; 300 V to ground)

A maintenance worker holding a limited building maintenance electrician (BME) license is asked to replace a failed ballast in a fluorescent troffer in a county courthouse. Is this work within the license?

Requirements at a glance

AgencyOregon Building Codes Division (BCD); state-run paper exam
ExperienceAn approved one-year training program, or 2,000 hours of work on appliances, switches, fixtures, fans, receptacles and ballasts
Exam28 questions, 2 hours, open book; 75% to pass
Books allowedOpen book: NEC with Oregon amendments, NEC Handbook, ORS 479, OAR Division 918 and the other references on BCD's list; silent non-programmable calculator
Fees$50 application fee (no separate exam fee); exempt from continuing education

Building maintenance workers applying to BCD for a limited building maintenance electrician (BME) license to maintain, repair and replace appliances, switches, fixtures, fans, receptacles and fluorescent ballasts in commercial office buildings, government buildings and board-designated facilities at not over 300 V to ground.

How to get licensed, step by step

  1. Apply to BCD

    Send the application, proof of qualifying training and experience, a high school diploma or GED, and the fee. Choose your proctor site on the application.

    Oregon Building Codes Division: licensing (opens in a new tab)

  2. Get your Letter of Authorization

    BCD mails the letter when your application is approved. Call the proctor site on it to book; you must test within 60 days of the letter.

    BCD: license exams and locations (opens in a new tab)

  3. Take the exam

    Bring the letter, photo ID, your approved books, pencils and a silent, non-programmable calculator. 75% is the passing score.

    BCD: license exams and locations (opens in a new tab)

  4. Results and retakes

    BCD grades the exam and mails the result in about 2 weeks. After a failure, wait 30 days and send a license reapplication form.

    BCD: license exams and locations (opens in a new tab)

How to prepare

  • The 2026 Oregon Electrical Specialty Code (2026 NEC) took effect October 1, 2026. BCD does not say which edition its exams test, so our questions follow the currently adopted code. Check your Letter of Authorization and the BCD materials list before you buy books.
  • BCD publishes no outline or topic weights, so our topic split is an estimate. The exam is open book: tab your NEC with Oregon amendments, ORS 479 and OAR Division 918 and practice finding answers fast.
  • Allowed: tabs, highlighting, printed errata and short margin notes. Not allowed: practice tests, class notes, calculation examples or added pages.
  • A BME works on systems not over 300 V to ground in commercial office and government buildings (OAR 918-282-0260). Drill Ohm's law, NEC 404, 406 and 410, fans, ballasts and basic overcurrent and grounding.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

    Official reference list (as published by the testing agency)
    • NFPA 70 / National Electrical Code (NEC) with Oregon amendments and errata
    • NEC Handbook and errata
    • Oregon Revised Statutes (ORS) Chapter 479
    • Oregon Administrative Rules (OAR) Division 918
    • American Electrician's Handbook (Hartwell); Electrical Black Book (Rapp); Ugly's Electrical References; Ferm's Fast Finder Index; Tom Henry's Key Word Index; Briganti NEC and Oregon Electrical Code key-word indexes
    • A silent, non-printing, non-programmable calculator
    • Tabs, highlighting, printed errata and short margin notes are allowed. Practice tests, class notes, calculation examples and added pages are not. (BCD materials list, rev. September 2026)

    What's on the exam

    Estimated topic weighting. No official breakdown is published:

    TopicQuestions
    Oregon Laws and BME Scope (OAR 918-282-0260; 300 V to ground)6
    Basic Electricity and Ohm's Law4
    Appliances, Fans and Ballasts4
    Switches, Receptacles and Light Fixtures (NEC 404, 406, 410)7
    Conductors, Overcurrent and Grounding Basics4
    Electrical Safety and Meters3

    Exam day details

    • Administered by the Oregon Building Codes Division (state-run paper exam at a proctor site).
    • Fee: No separate exam fee: the license application fee covers it ($50 for this license). Application fees are nonrefundable.
    • 28 questions, 2 hours, open book, 75% to pass (BCD license directory). BCD publishes no topic outline, so our topic split is an estimate derived from the license scope in OAR Division 918-282.
    • BCD mails a Letter of Authorization when your application is approved. Call the proctor site named on it to book; you must test within 60 days of the letter. Bring the letter and photo ID.
    • Proctor sites are in Bend, Eugene, Hermiston, Klamath Falls, Ontario, Pendleton, Portland, Roseburg, Salem and White City. BCD grades the paper exam and mails the result in about 2 weeks; results are not given by phone.
    • The passing score for all BCD licensing exams is 75%. After a failed exam you wait 30 days and send a license reapplication form; the result includes a strength and weakness report.
    • Bring your own pencils and, if you use one, a silent, non-printing, non-programmable calculator. Scratch paper is provided.
    • Qualification (BCD license directory): An approved one-year training program, or 2,000 hours of work on appliances, switches, fixtures, fans, receptacles and ballasts; high school diploma or GED.
    • The 2026 Oregon Electrical Specialty Code (2026 NEC) took effect October 1, 2026, replacing the 2023 code. BCD does not say which edition its exams test, so our questions follow the currently adopted 2026 code; where a section number changed, the explanation also gives the 2023 number.

    Note: BCD publishes no content outline, topic weights or question-count breakdown for the electrical exams, so our topic split is an estimate. The question count and time come from the BCD license directory. Our 2026 section numbers and rules were checked against NFPA's published 2026 revision records and Oregon's amendment table rather than the printed code, and BCD does not state which code edition the exams test.

    Frequently asked questions

    Who can take the Oregon limited building maintenance electrician exam?

    Candidates who meet BCD's qualification for this license: An approved one-year training program, or 2,000 hours of work on appliances, switches, fixtures, fans, receptacles and ballasts; high school diploma or GED. BCD mails a Letter of Authorization once your application is approved.

    What's on the exam?

    BCD publishes no outline or weights. Our topics follow the legal scope of the license in OAR Division 918-282 and the NEC with Oregon amendments, and our split is an estimate.

    Is the exam open book?

    Yes. You may bring the references on BCD's materials list, with tabs, highlighting and short margin notes. Practice tests, class notes and added pages are not allowed.

    What if I fail?

    Wait 30 days, then send BCD a license reapplication form to test again. Results come by mail in about 2 weeks.

    Free questions with answers

    Show all 10 free questions and answers
    1. A maintenance worker holding a limited building maintenance electrician (BME) license is asked to replace a failed ballast in a fluorescent troffer in a county courthouse. Is this work within the license?

      Answer: Yes, because fluorescent ballasts in a building occupied by a local government entity are named in the BME scope

      OAR 918-282-0260(1)(a) authorizes a BME to maintain, repair and replace fluorescent ballasts on the premises of commercial office buildings, buildings occupied by the state or a local government entity, and board-designated facilities. A county courthouse is occupied by a local government, so the work fits. The rule does not require a supervising electrician to sign off.

      Reference: Oregon Administrative Rules (OAR) Chapter 918, OAR 918-282-0260(1)(a)

    2. A BME is employed directly by the owner of a commercial office building. Under OAR 918-282-0260(1)(b), who must hold an electrical license?

      Answer: The BME must be licensed, but the owner and the owner's agent need not be

      OAR 918-282-0260(1)(b) says a BME may be employed by the owner of a commercial office building or the owner's agent, and that neither the owner nor the agent needs to be licensed. The individual doing the electrical work must still hold the BME license.

      Reference: Oregon Administrative Rules (OAR) Chapter 918, OAR 918-282-0260(1)(b)

    3. Three resistors of 10, 20 and 30 ohms are wired in series across a 120-volt supply. What is the voltage drop across the 20-ohm resistor?

      Answer: 40 volts

      Series resistance is 10 + 20 + 30 = 60 ohms, so current is 120 / 60 = 2 A. The drop across the 20-ohm resistor is 2 x 20 = 40 V. 20 V is the resistance value itself, 60 V is the drop across the 30-ohm resistor (2 x 30), and 120 V is the whole supply voltage, which is divided among all three resistors.

      Reference: Basic electrical theory (Ohm's law and the power formula), Series circuits

    4. A conductor with a resistance of 0.5 ohm carries 10 amperes. How much power is lost as heat in the conductor?

      Answer: 50 watts

      Power loss is P = I squared x R = 10 x 10 x 0.5 = 50 W. 5 W is I x R (volts, not watts), 200 W comes from I squared divided by R, and 20 W is I divided by R.

      Reference: Basic electrical theory (Ohm's law and the power formula), Power formula, P = I squared x R

    5. Under OSHA 29 CFR 1910.333(b)(2), what is required while an employee is exposed to contact with parts of fixed electric equipment that have been de-energized?

      Answer: The circuits energizing the parts shall be locked out or tagged or both

      Section 1910.333(b)(2) requires lockout and tagging of the circuits energizing fixed equipment while employees are exposed to it. Simply switching off, or relying on a push button, is not enough, and a note without a lock or tag does not meet the rule.

      Reference: 29 CFR Part 1910, Subpart S (OSHA), 29 CFR 1910.333(b)(2)

    6. An outlet box is marked by its manufacturer as suitable for the sole support of a ceiling-suspended (paddle) fan. What is the greatest fan weight such a box may support under 314.27(B)?

      Answer: 70 pounds

      Section 314.27(B) says boxes used as the sole support of a paddle fan shall be listed, marked for the purpose, and shall not support fans weighing more than 32 kg (70 lb). For fans over 35 lb the box marking must also give the maximum weight. 50 lb is the standard luminaire box requirement in 314.27(A)(2)(a).

      Reference: NFPA 70, National Electrical Code, 2026, 314.27(B)

    7. Which fluorescent ballast is NOT required to be thermally protected under 410.130(E)?

      Answer: A ballast in a fluorescent exit luminaire

      Section 410.130(E) exempts ballasts in fluorescent exit luminaires (E)(3), in egress luminaires energized only on loss of normal supply (E)(4), and simple reactance ballasts for straight tubular lamps (E)(2). Ballasts in ordinary indoor luminaires and replacement ballasts must be thermally protected.

      Reference: NFPA 70, National Electrical Code, 2026, 410.130(E)(2) through (E)(4)

    8. A 10 AWG copper conductor is used on a general branch circuit. What is the largest overcurrent device 240.4(D) allows?

      Answer: 30 amperes

      Section 240.4(D) caps 10 AWG copper at 30 A. The 60 degree C column of Table 310.16 shows 30 A for 10 AWG, and the 75 degree C column shows 35 A, but the small-conductor limit keeps the device at 30 A.

      Reference: NFPA 70, National Electrical Code, 2026, 240.4(D)

    9. A three-way switch is being replaced in a 120-volt lighting circuit. Under 406.30(A), in which conductor must the switching be done?

      Answer: Only in the ungrounded circuit conductor

      Section 406.30(A) requires three-way and four-way switches to be wired so that all switching is done only in the ungrounded circuit conductor. A switch in the grounded conductor would leave the lampholder energized with the switch off.

      Reference: NFPA 70, National Electrical Code, 2026, 406.30(A)

    10. Under 406.38(A), what is the highest the actuating means of a snap switch's operating handle may be above the floor, in its highest position?

      Answer: 6 feet 7 inches

      Section 406.38(A) requires switches to be operable from a readily accessible place and installed so the actuating means of the operating handle, in its highest position, is not more than 2.0 m (6 ft 7 in.) above the floor, working platform or finished grade. The exception lets switches adjacent to the equipment they supply be located higher.

      Reference: NFPA 70, National Electrical Code, 2026, 406.38(A)

    Sources

    Questions last verified November 10, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.