Oklahoma Sheet Metal Journeyman Exam: Practice Test & Licensing Guide

The PSI exam for an Oklahoma sheet metal journeyman license: 50 scored questions on duct sizing, fabrication and installation, plenums, venting, ventilation and exhaust, and safety. Open book, 70% to pass.

Questions
50
Time limit
2 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Duct Sizing, Design, and Hanging and Support Requirements

A trunk must carry 1,200 cfm without exceeding 900 fpm. Which listed rectangular size is the smallest that meets the velocity limit?

Requirements at a glance

AgencyOklahoma Construction Industries Board (CIB); exams by PSI
ExperienceSheet metal experience (hours not stated in the bulletin; see the CIB)
Exam50 scored questions, 2 hours, 70% (35)
Books allowedIMC (2018 or 2024 with Oklahoma revisions), ACCA Ductulator, SMACNA and NAIMA duct standards, 29 CFR 1926
Fee$92 to PSI per exam portion (non-refundable), plus CIB application and license fees
Retest30 days after a fail; 90 days after each later fail (electrical is always 30)

Sheet metal workers applying to the Oklahoma Construction Industries Board for a journeyman license to fabricate, install, repair, alter or extend sheet metal work while employed or supervised by a sheet metal contractor.

How to get licensed, step by step

  1. Register and log your hours

    Register with the CIB as an apprentice and log your hours under a licensed contractor (1 year is 2,000 hours). Have your employer's affidavits notarized.

    Oklahoma Construction Industries Board (CIB) (opens in a new tab)

  2. Apply to the CIB

    Send the CIB your application and notarized experience affidavits. When it approves you, you receive an Ok Con ID.

    Oklahoma Construction Industries Board (CIB) (opens in a new tab)

  3. Schedule with PSI

    Book your exam with PSI online or at (855) 834-8750. Contractor applicants also take the Business and Law portion.

    Schedule with PSI (Oklahoma contractor exams) (opens in a new tab)PSI: Oklahoma CIB Candidate Information Bulletin (effective 9/11/2026) (opens in a new tab)

  4. Pass and get licensed

    After you pass, send the CIB your results and license fee to receive your license.

    Oklahoma Construction Industries Board (CIB) (opens in a new tab)

How to prepare

  • All Oklahoma trade exams are open book, so the skill is finding answers fast: bound books, permanent tabs only, highlighting allowed, no writing.
  • Bring a silent, non-programmable calculator. The exam adds up to 10 unscored experimental questions that count against your time.
  • General knowledge (12) and ventilation and exhaust devices (12) are almost half the exam; tab IMC Chapters 5 and 6.
  • Duct fabrication and installation (10) leans on the SMACNA duct construction standards and the ATP Sheet Metal text.
  • Practise sizing round and rectangular duct with the Ductulator.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the IMC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • ACCA Ductulator (duct slide rule)
  • International Mechanical Code, 2018 or 2024 edition, with Oklahoma revisions
  • Fibrous Glass Duct Construction Standards, 5th Edition, 2002, NAIMA
  • HVAC Duct Construction Standards, Metal and Flexible, 3rd Edition, 2005, SMACNA
  • Sheet Metal, 1995 Edition, American Technical Publishers
  • 29 CFR Part 1926 (OSHA construction), or PSI's selections

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Knowledge12
Duct Sizing, Design, and Hanging and Support Requirements4
Duct Fabrication and Installation10
Plenums4
Appliance Venting and Combustion Air5
Ventilation and Exhaust Devices12
Safety3

Exam day details

  • Administered by PSI Services for the Oklahoma Construction Industries Board (CIB).
  • Fee: $92 to PSI per exam portion, non-refundable. CIB application and license fees are separate.
  • 50 scored questions in 120 minutes; 35 correct (70%) to pass.
  • Edition note: the bulletin allows the 2018 or 2024 IMC with Oklahoma revisions; the 2024 code may be used from 9/14/2026 and the 2018 code is no longer allowed as of 12/14/2026. Our questions follow the 2024 code with Oklahoma amendments.
  • If you fail, wait 30 days to retest; after each later failure the wait is 90 days.
  • Open book: bring your own bound copies of the allowed references. You may highlight, underline and index them beforehand with permanent tabs only; no writing and no sticky notes.
  • PSI may add up to 10 unscored experimental questions, which count against your time. A silent, non-printing, non-programmable calculator is allowed.
  • The CIB must approve your application first (you receive an Ok Con ID) before you can schedule with PSI.

Frequently asked questions

What's on the Oklahoma sheet metal journeyman exam?

50 scored questions: general knowledge 12, ventilation and exhaust devices 12, duct fabrication and installation 10, appliance venting and combustion air 5, duct sizing, design and hangers 4, plenums 4 and safety 3.

Is the sheet metal contractor exam different?

Yes. It is a longer exam (60 scored questions); contractors also pass Mechanical Business and Law.

Can I use the ACCA Ductulator?

Yes. It is the first reference on the bulletin list, along with the IMC, the SMACNA and NAIMA duct standards and the ATP Sheet Metal text.

Free questions with answers

Show all 10 free questions and answers
  1. A trunk must carry 1,200 cfm without exceeding 900 fpm. Which listed rectangular size is the smallest that meets the velocity limit?

    Answer: 16 in. x 12 in.

    Required area = 1,200 / 900 = 1.333 sq ft = 192 sq in. A 16 x 12 duct is exactly 192 sq in (900 fpm). The 14 x 10 (140 sq in, about 1,234 fpm) and 12 x 12 (144 sq in, 1,200 fpm) are too small, and 24 x 12 (288 sq in, 600 fpm) works but is larger than needed.

    Reference: General sheet metal practice, Duct airflow: cfm = fpm x area (sq ft)

  2. A contractor wants to set a gas-fired unit heater inside the above-ceiling return air plenum to save floor space. What does the IMC say?

    Answer: Fuel-fired appliances are not allowed to be installed within a plenum

    Section 602.1 (repeated in 602.1.3) states that fuel-fired appliances shall not be installed within a plenum. Listing, fire dampers, fire-area limits and small input ratings do not create an exception.

    Reference: 2024 International Mechanical Code (Oklahoma amendments), 602.1

  3. The two outdoor openings for a 140,000 Btu/h room are run through horizontal ducts to an exterior wall. What free area must each opening have?

    Answer: 70 square inches

    IFGC 304.6.1 raises the requirement to 1 square inch per 2,000 Btu/h when the openings communicate with the outdoors through horizontal ducts. 140,000 / 2,000 = 70 square inches each. The 35 square inch value applies to direct openings or vertical ducts.

    Reference: 2024 International Fuel Gas Code (Oklahoma amendments), 304.6.1

  4. A 16-foot-tall chimney serves an oil-fired appliance through a single-wall connector. Under the IMC, what is the maximum horizontal length of the connector?

    Answer: 12 feet

    IMC 803.10.2 limits the horizontal length of a single-wall connector to 75 percent of the height of the chimney or vent. 16 x 0.75 = 12 feet. 4 feet is 25 percent, 8 feet is 50 percent, and 16 feet would be 100 percent. (Gas appliances follow IFGC 503.10.9, which sets the same 75 percent limit for single-wall connectors.)

    Reference: 2024 International Mechanical Code (Oklahoma amendments), 803.10.2

  5. A 20 in. x 12 in. rectangular duct is carrying air at 600 fpm. How many cfm does it deliver?

    Answer: 1,000 cfm

    Area = 20 x 12 = 240 sq in = 240 / 144 = 1.667 sq ft. Airflow = 1.667 x 600 = 1,000 cfm. Using 240 sq in without converting gives 144,000, and 1,440 comes from multiplying 2.4 by 600.

    Reference: General sheet metal practice, Duct airflow: cfm = fpm x area (sq ft)

  6. An uninhabited attic of 1,500 square feet is ventilated mechanically instead of with natural openings. What minimum exhaust rate applies, and what controls it?

    Answer: 30 cfm, automatically controlled to run when relative humidity exceeds 60 percent

    IMC 406.1 allows mechanical ventilation of uninhabited spaces at not less than 0.02 cfm per square foot of horizontal area, automatically controlled to operate when relative humidity exceeds 60 percent. 1,500 x 0.02 = 30 cfm.

    Reference: 2024 International Mechanical Code (Oklahoma amendments), 406.1

  7. Which statement about a dryer exhaust duct termination is correct?

    Answer: It needs a backdraft damper and must not have a screen

    IMC 504.4 requires dryer exhaust ducts to terminate outside with a backdraft damper, and screens shall not be installed at the termination because lint clogs them. Fasteners that protrude into the duct are also prohibited.

    Reference: 2024 International Mechanical Code (Oklahoma amendments), 504.4

  8. What is the maximum length of a flexible air connector, and may it pass through a wall?

    Answer: 14 feet, and it may not pass through any wall, floor or ceiling

    IMC 603.6.2.1 limits flexible air connectors to 14 feet, and 603.6.2.2 bars them from passing through any wall, floor or ceiling. Flexible ducts and connectors also may not pass through any fire-resistance-rated assembly (607.7).

    Reference: 2024 International Mechanical Code (Oklahoma amendments), 603.6.2.1 and 603.6.2.2

  9. Which marking must appear on a pressure-sensitive tape used to seal metallic ducts?

    Answer: 181 B-FX

    IMC 603.9 requires tapes and mastics for metallic and flexible ducts to comply with UL 181B, marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. The 181 A- marks are for fibrous glass ductwork (A-P pressure-sensitive tape, A-M mastic, A-H heat-sensitive tape).

    Reference: 2024 International Mechanical Code (Oklahoma amendments), 603.9

  10. A 16-foot non-self-supporting (leaning) ladder is set against a wall. About how far from the wall should the base be placed?

    Answer: About 4 feet

    29 CFR 1926.1053(b)(5)(i) requires a non-self-supporting ladder to be used at an angle where the horizontal distance from the top support to the foot of the ladder is about one quarter of the working length (the length along the ladder between the foot and the top support). 16 / 4 = 4 feet, the familiar 4-to-1 ratio.

    Reference: 29 CFR 1926 (OSHA construction), 1926.1053(b)(5)(i)