Oklahoma licensing exam

Oklahoma Limited Residential Mechanical Journeyman and Installer Exam: Practice Test & Licensing Guide

The PSI exam for the Oklahoma Limited Residential Journeyman (Mechanical): 40 scored questions on ducts, vents, insulation, dryers, range hoods, clearances, access, combustion air and SMACNA symbols. Open book, 70% to pass. The Limited Residential Installer exam covers the same 13 topics with 30 questions.

Questions
40
Time limit
100 min
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Duct Systems

A 16-inch round supply trunk will be enclosed in a framed chase. Using the Oklahoma-amended Table M1601.1.1, what is the minimum galvanized thickness?

Requirements at a glance

AgencyOklahoma Construction Industries Board (CIB); exams by PSI
ExperienceSee the CIB for the Limited Residential Journeyman and Installer experience requirements (not stated in the bulletin)
ExamJourneyman: 40 scored questions, 100 minutes, 70% (28). Installer: 30 questions, 75 minutes, 70% (21)
Books allowedIRC (2018 or 2024 with Oklahoma revisions), SMACNA Symbols Sheet, OAC 158:50 (journeyman exam)
Fee$92 to PSI per exam portion (non-refundable), plus CIB application and license fees
Retest30 days after the first fail; 90 days after each later fail

Mechanical workers applying to the Oklahoma Construction Industries Board for a Limited Residential Journeyman (Mechanical) or Limited Residential Installer license. The scope is complete new systems in detached one- and two-family dwellings and townhouses up to 3 stories: cooling of 5 tons or less, heating of 150,000 Btu/h or less, and humidifiers, filters, kitchen hoods, exhaust fans and dryer vents. It excludes fuel gas piping, welding, soldering, brazing, and the final refrigerant line and final electrical connections. The installer license is for new construction only.

How to get licensed, step by step

  1. Register and log your hours

    Register with the CIB as an apprentice and log your hours under a licensed contractor (1 year is 2,000 hours). Have your employer's affidavits notarized.

    Oklahoma Construction Industries Board (CIB) (opens in a new tab)

  2. Apply to the CIB

    Send the CIB your application and notarized experience affidavits. When it approves you, you receive an Ok Con ID.

    Oklahoma Construction Industries Board (CIB) (opens in a new tab)

  3. Schedule with PSI

    Book your exam with PSI online or at (855) 834-8750. Contractor applicants also take the Business and Law portion.

    Schedule with PSI (Oklahoma contractor exams) (opens in a new tab)PSI: Oklahoma CIB Candidate Information Bulletin (effective 9/11/2026) (opens in a new tab)

  4. Pass and get licensed

    After you pass, send the CIB your results and license fee to receive your license.

    Oklahoma Construction Industries Board (CIB) (opens in a new tab)

How to prepare

  • All Oklahoma trade exams are open book, so the skill is finding answers fast: bound books, permanent tabs only, highlighting allowed, no writing.
  • Bring a silent, non-programmable calculator. The exam adds up to 10 unscored experimental questions that count against your time.
  • The installer exam covers the same 13 topics as the journeyman exam with fewer questions, so one bank prepares you for both.
  • Duct systems (10 of 40) is the biggest topic: IRC Chapter 16, including Oklahoma's replacement of Table M1601.1.1.
  • Know the scope limits: 5 tons of cooling or less, 150,000 Btu/h of heating or less, and no gas piping, brazing or final refrigerant and electrical connections.
  • Learn the SMACNA Symbols Sheet; it is a short, easy 3 questions.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the IRC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Residential Code, 2018 or 2024 edition, with Oklahoma revisions (2024 usable from 9/14/2026; 2018 not allowed from 12/14/2026)
  • Oklahoma Administrative Code Title 158, Chapter 50 (journeyman exam only; not listed for the installer exam)
  • SMACNA Symbols Sheet

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Duct Systems10
Vents4
Insulation3
Clothes Dryer3
Range Hoods1
Clearances3
Access4
Appliance Installation1
Restroom Exhaust Systems1
Combustion Air3
Piping1
General Installation3
SMACNA Symbols3

Exam day details

  • Administered by PSI Services for the Oklahoma Construction Industries Board (CIB).
  • Fee: $92 to PSI per exam portion, non-refundable. CIB application and license fees are separate.
  • Journeyman: 40 scored questions in 100 minutes; 28 correct (70%) to pass. This page's simulation uses the journeyman blueprint.
  • Installer: 30 scored questions in 75 minutes; 21 correct (70%) to pass. It covers the same 13 topics (duct systems 9, vents 2, insulation 2, clothes dryer 2, range hoods 1, clearances 2, access 3, appliance installation 1, restroom exhaust 1, combustion air 2, piping 1, general installation 2, SMACNA symbols 2). Practice with this bank works for both levels.
  • Edition note: the bulletin allows the 2018 or 2024 IRC with Oklahoma revisions; the 2024 code may be used from 9/14/2026 and the 2018 code is no longer allowed as of 12/14/2026. Our questions follow the 2024 code with Oklahoma amendments.
  • If you fail, wait 30 days to retest; after each later failure the wait is 90 days.
  • Open book: bring your own bound copies of the allowed references. You may highlight, underline and index them beforehand with permanent tabs only; no writing and no sticky notes.
  • PSI may add up to 10 unscored experimental questions, which count against your time. A silent, non-printing, non-programmable calculator is allowed.
  • The CIB must approve your application first (you receive an Ok Con ID) before you can schedule with PSI.

Frequently asked questions

Is there one exam for the journeyman and the installer?

They are two PSI exams with the same 13 topics: 40 questions in 100 minutes for the journeyman (28 to pass) and 30 questions in 75 minutes for the installer (21 to pass). One question bank here prepares you for both.

What does the limited residential license cover?

Complete new systems in detached one- and two-family dwellings and townhouses up to 3 stories, with cooling of 5 tons or less and heating of 150,000 Btu/h or less. It excludes fuel gas piping, welding, soldering, brazing, and final refrigerant line and electrical connections.

Which books are allowed?

The IRC with Oklahoma revisions and the SMACNA Symbols Sheet for both levels, plus OAC Title 158, Chapter 50 for the journeyman exam.

Free questions with answers

Show all 10 free questions and answers
  1. A 16-inch round supply trunk will be enclosed in a framed chase. Using the Oklahoma-amended Table M1601.1.1, what is the minimum galvanized thickness?

    Answer: 0.016 inch (No. 28 gage)

    Round ducts over 14 inches fall in the second row of the Oklahoma table: 0.016 inch, equivalent to No. 28 gage. 0.013 inch applies only to ducts 14 inches or less, and 0.019 inch applies to exposed rectangular ducts over 14 inches.

    Reference: 2024 International Residential Code (Oklahoma amendments), Table M1601.1.1

  2. A natural draft vent serves an oil-burning appliance. How far above the highest connected appliance outlet must the vent terminate?

    Answer: Not less than 5 feet

    Section M1804.2.3 requires vents for natural draft appliances to terminate at least 5 feet (1524 mm) above the highest connected appliance outlet. The 2-foot and 10-foot numbers belong to the Type L roof termination rule of M1804.2.4.

    Reference: 2024 International Residential Code (Oklahoma amendments), M1804.2.3

  3. A factory-made flexible duct has an actual outside diameter of 11 inches and a nominal inside diameter of 7 inches. What installed insulation thickness is used to determine its R-value under Section M1601.3?

    Answer: 2 inches

    For factory-made flexible air ducts the installed thickness is the difference between the actual outside diameter and the nominal inside diameter, divided by two: (11 - 7) / 2 = 2 inches. Forgetting to divide by two gives 4 inches; (11 + 7) / 2 = 9 inches is the average diameter, not the thickness.

    Reference: 2024 International Residential Code (Oklahoma amendments), M1601.3

  4. Which statement about screens on a dryer exhaust duct termination is correct under Oklahoma's version of Section M1502.3?

    Answer: Screens shall not be installed at the duct termination

    Oklahoma's amended M1502.3 states screens shall not be installed at the duct termination, which would trap lint. Terminations require a backdraft damper instead.

    Reference: 2024 International Residential Code (Oklahoma amendments), M1502.3

  5. Which description of the duct serving a domestic kitchen range hood meets Section M1503.3?

    Answer: Smooth interior, airtight, with a backdraft damper, independent of other exhaust systems and discharging outdoors

    Section M1503.3 requires the range hood duct to have a smooth interior surface, be airtight, have a backdraft damper, be independent of all other exhaust systems and discharge to the outdoors. It may not terminate in an attic, crawl space or inside the building, except for listed ductless hoods installed per their instructions.

    Reference: 2024 International Residential Code (Oklahoma amendments), M1503.3

  6. What governs the clearances from unprotected combustible materials for an appliance installed in a dwelling under Section M1306.1?

    Answer: The clearances on the appliance label and in the manufacturer's installation instructions

    Section M1306.1 requires appliances to be installed with the clearances from unprotected combustible materials shown on the appliance label and in the manufacturer's instructions. Those clearances can be reduced only by the methods in M1306.2.

    Reference: 2024 International Residential Code (Oklahoma amendments), M1306.1

  7. Which furnace location violates the access requirement of Section M1305.1?

    Answer: A furnace whose service requires removing a permanently installed duct that does not connect to it

    M1305.1 requires appliances to be located so they can be inspected, serviced, repaired and replaced without removing permanent construction, other appliances, or any piping or ducts not connected to the appliance in question.

    Reference: 2024 International Residential Code (Oklahoma amendments), M1305.1

  8. Combustion air for an oil-fired appliance is provided in accordance with which document, per Section M1701.1?

    Answer: NFPA 31

    Section M1701.1 says oil-fired appliances shall be provided with combustion air in accordance with NFPA 31. Solid fuel-burning appliances follow the appliance manufacturer's installation instructions. NFPA 54 is the national fuel gas code, and gas is handled by Chapter 24.

    Reference: 2024 International Residential Code (Oklahoma amendments), M1701.1

  9. Oklahoma amended Section M1411.9 to allow a condensate drain to end at an approved pit or French drain. What is the minimum size and fill?

    Answer: 24 inches by 24 inches by 24 inches, or equivalent, of 1-inch washed rock

    OAC 748:20-6-19 modified M1411.9 to permit termination at an approved pit or French drain of at least 24 x 24 x 24 inches, or equivalent, of 1-inch washed rock. Condensate may not discharge into a street, alley or other area so as to create a nuisance.

    Reference: 2024 International Residential Code (Oklahoma amendments), M1411.9

  10. How does the SMACNA symbols sheet define a supply register, abbreviated SR?

    Answer: A grille plus an integral volume control

    On the sheet, SUPPLY REGISTER (SR) is defined as a grille plus an integral volume control. A supply grille (SG) has no volume control.

    Reference: SMACNA HVAC Duct Construction Standards Metal and Flexible, 3rd Edition, Figure 1-3 Symbols for HVAC Systems (I-P)

Sources

Questions last verified November 3, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.