Ohio EPA Water Supply Class I Operator Exam: Practice Test & Licensing Guide

The Ohio EPA entry-level drinking water treatment operator exam (WPI Water Treatment Class I): 100 questions on treatment processes, lab tests, equipment, source water and safety. 70% to pass.

Questions
100
Time limit
3 hours
Passing score
70%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Security, Safety, and Administrative Procedures

A gas monitor at the hatch of a clearwell that is a permit-required confined space reads 19.0% oxygen. What does this reading mean for entry?

Requirements at a glance

AgencyOhio EPA; exam by Water Professionals International (WPI) at PSI test centers
EducationHigh school diploma or equivalent
Experience12 months of operating experience at a public water system for Class I (you can test first and finish it as an operator in training)
Exam100 scored questions plus up to 10 pretest items, 3 hours, 70 to pass, closed book; WPI formula sheet provided
FeesWPI's exam fee at PSI, plus Ohio EPA's $45 certification application fee

Anyone working toward an Ohio EPA Class I Water Supply certificate, which is needed to run or be in responsible charge at a Class I public water treatment plant. You can test before you have the 12 months of operating experience and finish it as an operator in training.

How to get licensed, step by step

  1. Check the experience rules

    Class I needs 12 months of hands-on operating experience. If you don't have it yet, you can still test: pass and Ohio EPA makes you an operator in training with up to 60 months to finish.

    Ohio EPA: how to become a certified operator (opens in a new tab)

  2. Schedule the WPI exam at PSI

    Register at PSI, choose Water/Wastewater, then Ohio EPA, then the Water Supply Class I exam. Ohio test sites include Cleveland, Cincinnati, Columbus, Akron, Cambridge, Troy and Toledo.

    Schedule with PSI (Ohio EPA / WPI exams) (opens in a new tab)WPI: Ohio EPA certification (opens in a new tab)

  3. Study the Need-to-Know Criteria

    WPI's Need-to-Know Criteria list every task the exam covers, how many questions come from each area and the main reference books.

    WPI Need-to-Know Criteria: Water Treatment Class I (opens in a new tab)

  4. Apply for certification

    After you pass with 70 or better and can document your experience, apply through the Ohio EPA eBusiness Center and pay the $45 application fee.

    Ohio EPA: operator exam information (opens in a new tab)

How to prepare

  • Treatment process (31) and equipment operation and maintenance (26) are more than half the exam: coagulation, filtration, disinfection and CT, pumps and chemical feeders.
  • About 10 questions are math. Practice the pounds formula, detention time, filter loading and hypochlorite problems with the WPI formula sheet you'll get at the exam.
  • Know the federal numbers that show up as lab and admin questions: turbidity limits, residual disinfectant rules, coliform sampling and the public notice tiers.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

Official reference list (as published by the testing agency)
  • AWWA Water System Operations (WSO): Water Treatment, Grade 1
  • CSUS Office of Water Programs, Water Treatment Plant Operation, Volume 1
  • AWWA Basic Science Concepts and Applications, 4th Edition
  • WPI Water Treatment and Distribution Formula/Conversion Table (given to you at the exam)

What's on the exam

Official content outline from Water Professionals International (WPI) (number of questions per topic):

TopicQuestions
Treatment Process31
Laboratory Analysis16
Equipment Operation and Maintenance26
Source Water Characteristics15
Security, Safety, and Administrative Procedures12

Exam day details

  • Administered by Water Professionals International (WPI) for Ohio EPA, at PSI test centers.
  • Fee: WPI's exam fee, paid to PSI when you schedule (check PSI for the current amount), plus Ohio EPA's $45 certification application fee after you pass.
  • 100 scored questions plus up to 10 unscored pretest questions in 3 hours. You need 70 to pass.
  • Ohio EPA uses WPI's standardized Water Treatment Class I exam for its Water Supply Class I certificate. About 10 of the 100 questions are calculations.
  • Closed book. WPI provides its formula/conversion table, and you may bring a silent, non-programmable calculator.
  • Taken by computer at PSI test centers in Ohio (Cleveland, Cincinnati, Columbus, Akron, Cambridge, Troy and Toledo) or anywhere in the country.
  • You need a high school diploma or equivalent. If you pass before you have 12 months of operating experience at a public water system, you become an operator in training and have up to 60 months to finish the experience.

Frequently asked questions

What's on the Ohio Water Supply Class I exam?

100 scored questions from WPI's Water Treatment Class I outline: treatment process 31, equipment operation and maintenance 26, laboratory analysis 16, source water characteristics 15 and security, safety and administrative procedures 12.

Is the Ohio Class I water exam the same as the WPI (ABC) exam?

Yes. Ohio EPA's equivalency chart maps its Water Supply Class I certificate to WPI's Water Treatment Class I exam. When you register at PSI you choose the Ohio EPA program, and the matching WPI exam is selected for you.

Can I take the exam before I have experience?

Yes. With a high school diploma or equivalent you can test right away. If you pass without the 12 months of experience, Ohio EPA designates you an operator in training and you have up to 60 months to document it.

Free questions with answers

Show all 10 free questions and answers
  1. A gas monitor at the hatch of a clearwell that is a permit-required confined space reads 19.0% oxygen. What does this reading mean for entry?

    Answer: The space is oxygen-deficient, so it has a hazardous atmosphere and must not be entered as-is

    OSHA defines an oxygen-deficient atmosphere as less than 19.5% oxygen by volume, and an atmosphere below 19.5% or above 23.5% is a hazardous atmosphere. At 19.0% the space must be ventilated and retested before anyone enters. The 18%-22% range is not OSHA's limit; the acceptable band is 19.5% to 23.5%.

    Reference: 29 CFR 1910.146 (OSHA Permit-Required Confined Spaces), 1910.146(b), definitions of hazardous atmosphere and oxygen deficient atmosphere

  2. A routine distribution sample is positive for E. coli and the system has confirmed an E. coli MCL violation. How soon must the public be notified?

    Answer: As soon as practical, but no later than 24 hours after the system learns of the violation

    An E. coli MCL violation is a Tier 1 situation. Tier 1 notice must be given as soon as practical but no later than 24 hours after the system learns of it, and the system must consult the state within 24 hours. The 30-day deadline is for Tier 2 notices, and the annual report is the vehicle for some Tier 3 notices.

    Reference: 40 CFR Part 141 (National Primary Drinking Water Regulations), 141.202(a) Table 1 item (1) and 141.202(b)(1)

  3. What must be in a sample bottle used to collect a coliform sample from a chlorinated system?

    Answer: Sodium thiosulfate, to neutralize the chlorine residual

    When chlorinated water is tested for coliforms, sodium thiosulfate must be added to the bottle before sterilization to neutralize the residual. Otherwise the chlorine keeps killing bacteria in the bottle and the result reads falsely low. Nitric acid is the preservative for metals samples.

    Reference: 40 CFR Part 141 (National Primary Drinking Water Regulations), 141.852(a)(4)

  4. For a conventional filtration plant, what turbidity must the combined filter effluent meet in at least 95% of the measurements taken each month?

    Answer: 0.3 NTU or less

    Conventional and direct filtration plants must keep combined filter effluent turbidity at or below 0.3 NTU in at least 95% of monthly measurements, and it must never exceed 1 NTU. 0.1 NTU is a common optimization goal, not the regulatory limit.

    Reference: 40 CFR Part 141 (National Primary Drinking Water Regulations), 141.173(a)(1)-(2)

  5. What are the MCLs for the two regulated groups of chlorination byproducts, total trihalomethanes (TTHM) and five haloacetic acids (HAA5)?

    Answer: TTHM 0.080 mg/L and HAA5 0.060 mg/L

    The MCLs are 0.080 mg/L (80 ug/L) for TTHM and 0.060 mg/L (60 ug/L) for HAA5, based on locational running annual averages. Reversing the two is the classic mistake. 0.100 mg/L was the old TTHM limit, and 0.010 mg/L is the bromate MCL.

    Reference: 40 CFR Part 141 (National Primary Drinking Water Regulations), 141.64(b)(1)

  6. A plant treats 1.8 MGD and wants a chlorine gas dose of 2.5 mg/L. How many pounds of chlorine per day should be fed?

    Answer: 37.5 lb/day

    Feed rate (lb/day) = dose (mg/L) x flow (MGD) x 8.34 lb/gal = 2.5 x 1.8 x 8.34 = 37.5 lb/day. Chlorine gas is essentially 100% pure, so no purity correction is needed. 4.5 lb/day leaves out the 8.34 factor.

    Reference: WPI Water Treatment/Distribution Formula/Conversion Table, Feed Rate, lb/day

  7. Which treatment process skips the sedimentation step and sends coagulated (and sometimes flocculated) water straight to the filters?

    Answer: Direct filtration

    Direct filtration adds a coagulant and rapid mix, sometimes with flocculation, then applies the water directly to dual- or multi-media filters with no sedimentation basin. It suits low-turbidity raw water, and a coagulant must be used at all times.

    Reference: EPA Guidance Manual for Compliance with the Filtration and Disinfection Requirements (SWTR Guidance Manual, 1991), Section 4.3.4, Direct Filtration

  8. Before starting a centrifugal pump, why must it be primed?

    Answer: It can't pump air, and running without water damages seals and wear rings

    A centrifugal pump can't pump air, so the casing and suction piping must be full of water before it starts. Running without water also starves seals and wear rings of lubrication and can seize the rotating element.

    Reference: UFC 3-230-02, Operation and Maintenance: Water Supply Systems (2001), Table 11, routine operations checklist for centrifugal pumps (prestart checks)

  9. A pump delivers 500 gpm against a total head of 180 ft. The pump is 75% efficient and the motor is 90% efficient. What is the motor horsepower?

    Answer: 33.7 hp

    Motor hp = flow x head / (3,960 x pump eff x motor eff) = 500 x 180 / (3,960 x 0.75 x 0.90) = 90,000 / 2,673 = 33.7 hp. 22.7 hp is water horsepower (no efficiencies) and 30.3 hp is brake horsepower (pump efficiency only).

    Reference: WPI Water Treatment/Distribution Formula/Conversion Table, Horsepower, Motor, hp

  10. Compared with surface water, groundwater typically has:

    Answer: Lower turbidity, steadier temperature and more minerals

    Groundwater is naturally filtered by soil, so turbidity is low and temperature is steady, but it picks up dissolved minerals, hardness, iron and manganese. Surface water quality swings with storms and seasons and carries more turbidity, algae and organics.

    Reference: UFC 3-230-02, Operation and Maintenance: Water Supply Systems (2001), Par. 4.7.1-4.7.2, physical and chemical characteristics; par. 5.4.8, iron and manganese

Sources

Questions last verified October 26, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.