Wastewater Treatment Operator Class I Exam (WPI/ABC): Practice Test & Licensing Guide

The WPI (formerly ABC) standardized Wastewater Treatment Operator Class I exam: 100 questions on equipment, treatment processes, lab work and safety.

Questions
100
Time limit
Not officially released
Passing score
70%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Equipment Evaluation, Maintenance and Operation

A headworks screening device has parallel bars spaced 3 inches apart. What is this device usually called?

Requirements at a glance

ExamWastewater Treatment Class I: 100 scored questions, closed book, formula sheet provided
Colorado equivalentWastewater Treatment Class D
Passing scoreSet by your state; 70 in Colorado and most WPI states
Colorado fees$50 CDPHE application + $104 PSI exam

Entry-level wastewater treatment plant operators in states that use WPI exams, including Colorado Wastewater Treatment Class D and Idaho Wastewater Treatment Class I.

How to get certified, step by step

  1. Meet your state's eligibility rules

    Most states need a high school diploma or GED and some experience. In Colorado: the free regulatory course for your certificate type, plus one month of supervised experience for Class D or 1.

    CDPHE: which certificate is right for you (opens in a new tab)

  2. Apply to your certifying agency

    Apply to your state program (in Colorado, CDPHE's Certified Water Professionals program). Once approved, you get instructions to schedule with PSI.

    CDPHE: steps to becoming certified (Colorado) (opens in a new tab)

  3. Take the exam

    At a PSI test center or by remote proctoring. WPI's formula/conversion sheet is provided; bring a basic calculator.

  4. Get certified

    Your state issues the certificate after you pass. Higher classes need more experience and the next exam level.

How to prepare

  • Learn the formula sheet before exam day: know which formula each problem needs and practice unit conversions (gallons, cubic feet, pounds, psi, feet of head).
  • Equipment (39) and process control (38) are most of the exam: pumps, screens, grit, clarifiers, activated sludge and ponds.
  • Practice loading (lb/day), detention time and percent removal problems.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

Official reference list (as published by the testing agency)
  • WPI formula/conversion sheet (provided at the exam)
  • 40 CFR Parts 141 and 143 (Safe Drinking Water Act rules) and 40 CFR Part 503 (biosolids)
  • 29 CFR 1910 and 1926 (OSHA safety)

What's on the exam

Official content outline from Water Professionals International (WPI, formerly ABC); delivered by PSI (number of questions per topic):

TopicQuestions
Equipment Evaluation, Maintenance and Operation39
Treatment Process Evaluation and Adjustment38
Laboratory Analysis10
Security, Safety and Administrative Procedures13

Exam day details

  • Administered by Water Professionals International (WPI, formerly ABC); delivered by PSI for most states.
  • Fee: Set by your state. In Colorado: $104 to PSI plus a $50 CDPHE application fee.
  • 100 scored questions, about 10 of them calculations.
  • Up to 10 extra unscored pretest questions are mixed in.
  • Passing is set by your state; Colorado and most WPI states use 70. WPI's 2025 exams are reported as scaled scores.
  • WPI's formula/conversion sheet is provided; bring a basic non-programmable calculator.
  • Time is set by the state and PSI (typically 3 hours for a 100-question exam); PSI confirms it when you schedule.
  • Colorado: Class D/1 = WPI Class I up to Class A/4 = Class IV. You need a high school diploma or GED and Colorado's free regulatory course.

Frequently asked questions

Which Colorado certificate uses the Wastewater Treatment Class I exam?

Colorado Wastewater Treatment Class D. Class C, B and A use WPI Class II, III and IV.

Is the wastewater exam scored on a scale?

WPI's 2025 wastewater exams are reported as scaled scores, so 70 is a scaled passing score rather than exactly 70 questions correct.

Does Idaho use this exam?

Idaho operators are licensed by DOPL's Board of Drinking Water and Wastewater Professionals in Classes I to IV, and Idaho's operator exams are ABC (now WPI) exams. Idaho's Class I matches WPI Class I. Check with DOPL for the current application and exam steps.

Free questions with answers

Show all 10 free questions and answers
  1. A headworks screening device has parallel bars spaced 3 inches apart. What is this device usually called?

    Answer: A bar rack

    Bars spaced 3/8 inch to 2 inches apart make a bar screen. Once the openings are wider than 2 inches, the device is called a bar rack. Bar racks are often installed in bypass channels to catch large debris while the main screen is out of service. A comminutor shreds solids instead of removing them, and a fine screen has much smaller openings than either.

    Reference: New Mexico Wastewater Systems Operator Certification Study Manual, Chapter 3: Plant Pretreatment, Bar Screens

  2. A primary clarifier receives influent with 220 mg/L suspended solids, and its effluent contains 121 mg/L. What is the suspended solids removal efficiency?

    Answer: 45%

    Removal (%) = (In - Out) / In x 100 = (220 - 121) / 220 x 100 = 99 / 220 x 100 = 45%. That falls in the typical 40% to 60% range for suspended solids in a primary clarifier. Choice 55% is Out / In, which is the fraction remaining, not removed. Choice 82% divides by the effluent instead of the influent. Choice 99 is the mg/L removed, not a percentage.

    Reference: New Mexico Wastewater Systems Operator Certification Study Manual, Chapter 6: Sedimentation, Calculation of Clarifier Efficiency

  3. Why are positive displacement pumps usually chosen for primary sludge pumping and chemical feeding?

    Answer: Their output stays nearly constant as pressure changes

    A positive displacement pump delivers about the same volume on every stroke or revolution, whatever the discharge pressure. That makes it possible to keep accurate records of chemical doses and pounds of solids pumped. A centrifugal pump's flow falls as head rises, and centrifugals are the high-flow, low-head choice. Running a positive displacement pump against a closed valve is dangerous.

    Reference: New Mexico Wastewater Systems Operator Certification Study Manual, Chapter 8: Mechanical Systems, introduction and Table 8.1 - Pump Characteristics

  4. A centrifugal pump is rated for a 240-ft shutoff head. With the discharge valve briefly closed, the gauges show only 200 ft. A tachometer confirms the pump is at design speed. What is the most likely cause?

    Answer: Worn wearing rings or a worn impeller

    Shutoff head is found by subtracting the suction gauge reading from the discharge reading while the discharge valve is closed briefly (no more than about a minute). If the result is below the curve and the speed is correct, internal recirculation through worn wearing rings or a worn impeller is the likely cause. A single-phasing motor would slow down, which the tachometer ruled out. A larger suction does not cause cavitation.

    Reference: New Mexico Wastewater Systems Operator Certification Study Manual, Chapter 8: Mechanical Systems, Shut Off Head; Checking Shutoff Head

  5. Which feature is required for a properly designed gas chlorinator room?

    Answer: Floor-level ventilation, with switches outside the room

    Chlorine gas is about 2.5 times heavier than air and settles to the lowest point, so ventilation must be at floor level. Light and vent switches belong outside the room so the space can be ventilated before anyone enters. A window in the door lets others see an operator inside. Ceiling exhaust would leave the gas pooled on the floor.

    Reference: New Mexico Wastewater Systems Operator Certification Study Manual, Chapter 9: Disinfection, General Chlorine Safety; Chlorinator Room

  6. To save energy, an operator has kept aeration basin DO at about 0.3 mg/L for several weeks. Sludge in the secondary clarifier is now settling poorly. What is the most likely cause?

    Answer: Low DO has favored filamentous bacteria

    A minimum aeration basin DO of about 1.0 mg/L is recommended for most activated sludge processes. When DO stays too low for long periods, undesirable organisms such as filamentous bacteria can take over and cause poor settling (bulking). Nitrification needs oxygen, so low DO suppresses it. Low DO does not make floc denser, and it does not set the F:M ratio.

    Reference: New Mexico Wastewater Systems Operator Certification Study Manual, Chapter 10: Activated Sludge, Maintaining Proper Dissolved Oxygen and Mixing Levels

  7. An activated sludge plant has thick, dark foam on the aeration basin, dark brown mixed liquor, and tiny pin floc in the effluent. Which process adjustment is indicated?

    Answer: Increase wasting to raise the F:M ratio

    Thick dark foam, dark brown or reddish mixed liquor, sludge floating in the clarifier and pin floc are classic signs of a low F:M (too many old organisms for the food supply). The correction is to waste more sludge, which lowers MLSS and raises F:M. Reducing wasting is the response to a high F:M, which shows white frothy foam and light tan mixed liquor.

    Reference: New Mexico Wastewater Systems Operator Certification Study Manual, Chapter 10: Activated Sludge, Determining a Treatment Plant's F:M

  8. An aeration basin holds 0.5 MG. It receives 1.0 MGD of primary effluent with a BOD of 150 mg/L. The MLSS is 3,000 mg/L and the MLVSS is 2,400 mg/L. What is the F:M ratio?

    Answer: 0.125

    Food = 1.0 MGD x 150 mg/L x 8.34 = 1,251 lb BOD/day. Microorganisms = 0.5 MG x 2,400 mg/L x 8.34 = 10,008 lb MLVSS. F:M = 1,251 / 10,008 = 0.125. Choice 0.10 uses MLSS instead of MLVSS, which is what the formula sheet calls for. Choice 8.0 inverts the ratio. Choice 1.04 leaves out the 8.34 on the MLVSS side only.

    Reference: WPI Wastewater Formula/Conversion Table, Food/Microorganism Ratio; Loading Rate; Mass, lb

  9. An unseeded BOD test uses 30 mL of sample in a 300-mL BOD bottle. The initial DO is 8.6 mg/L, and the DO after 5 days is 4.1 mg/L. What is the BOD of the sample?

    Answer: 45 mg/L

    BOD (unseeded) = (initial DO - final DO) x 300 mL / sample volume = (8.6 - 4.1) x 300 / 30 = 4.5 x 10 = 45 mg/L. The bottle also meets the depletion rules: at least 2.0 mg/L used and at least 1.0 mg/L left. Choice 4.5 skips the dilution factor. Choice 86 uses only the initial DO. Choice 127 adds the two DO readings instead of subtracting.

    Reference: WPI Wastewater Formula/Conversion Table, Biochemical Oxygen Demand (unseeded), mg/L

  10. Before a crew enters a wet well that is a permit-required confined space, the attendant tests the atmosphere with a multi-gas meter. In what order should the hazards be tested?

    Answer: Oxygen, then combustible gases, then toxic gases

    OSHA requires testing first for oxygen, then combustible gases and vapors, then toxic gases and vapors. Combustible-gas sensors depend on adequate oxygen to read correctly, which is why oxygen comes first. The space should be tested at the top, middle and bottom and monitored throughout the entry, because gases such as H2S settle low and methane rises.

    Reference: 29 CFR 1910.146 (Permit-required confined spaces), 1910.146(d)(5)(iii)