Ohio licensing exam

Ohio EPA Wastewater (Water Reclamation) Class I Operator Exam: Practice Test & Licensing Guide

The Ohio EPA entry-level wastewater treatment operator exam (WPI Wastewater Treatment Class I): 100 questions on equipment, treatment processes, lab tests and safety. 70% to pass.

Questions
100
Time limit
3 hours
Passing score
70%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Laboratory Analysis

What is the maximum holding time for a wastewater BOD sample kept at 6 C or colder?

Requirements at a glance

AgencyOhio EPA; exam by Water Professionals International (WPI) at PSI test centers
EducationHigh school diploma or equivalent
Experience12 months of operating experience at a treatment works for Class I (you can test first and finish it as an operator in training)
Exam100 scored questions plus up to 10 pretest items, 3 hours, 70 to pass, closed book; WPI formula sheet provided
FeesWPI's exam fee at PSI, plus Ohio EPA's $45 certification application fee

Anyone working toward an Ohio EPA Class I Water Reclamation (wastewater treatment) certificate, which is needed to run or be in responsible charge at a Class I wastewater treatment plant. You can test before you have the 12 months of operating experience and finish it as an operator in training.

How to get licensed, step by step

  1. Check the experience rules

    Class I needs 12 months of hands-on operating experience. If you don't have it yet, you can still test: pass and Ohio EPA makes you an operator in training with up to 60 months to finish.

    Ohio EPA: how to become a certified operator (opens in a new tab)

  2. Schedule the WPI exam at PSI

    Register at PSI, choose Water/Wastewater, then Ohio EPA, then the Wastewater Treatment (Water Reclamation) Class I exam. Ohio test sites include Cleveland, Cincinnati, Columbus, Akron, Cambridge, Troy and Toledo.

    Schedule with PSI (Ohio EPA / WPI exams) (opens in a new tab)WPI: Ohio EPA certification (opens in a new tab)

  3. Study the Need-to-Know Criteria

    WPI's Need-to-Know Criteria list every task the exam covers, how many questions come from each area and the main reference books.

    WPI Need-to-Know Criteria: Wastewater Treatment Class I (opens in a new tab)

  4. Apply for certification

    After you pass with 70 or better and can document your experience, apply through the Ohio EPA eBusiness Center and pay the $45 application fee.

    Ohio EPA: operator exam information (opens in a new tab)

How to prepare

  • Equipment (39) and treatment process (38) make up most of the exam: pumps, blowers, clarifiers, activated sludge control, disinfection and solids handling.
  • Expect process control math such as F/M, MCRT, SVI, surface overflow and solids loading. Work problems with the WPI wastewater formula sheet.
  • Learn to read the process: aeration tank color and foam, settleometer curves, rising sludge and what each one tells you to adjust.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

  • CSUS Office of Water Programs: Operation of Wastewater Treatment Plants, Volumes 1 and 2 (8th ed.)Essential

    WPI's primary reference for every content area of the Class I wastewater exam.

    Office of Water Programs (opens in a new tab)

  • WEF Wastewater Treatment Fundamentals I: Liquid Treatment

    Secondary reference for treatment process and laboratory questions.

    WEF store (opens in a new tab)

  • Ohio EPA Class A Training Manual (wastewater package plants)

    Free Ohio EPA study manual. Written for Class A, but its activated sludge troubleshooting and maintenance chapters fit Class I well.

    Ohio EPA (PDF) (opens in a new tab)

Official reference list (as published by the testing agency)
  • CSUS Office of Water Programs, Operation of Wastewater Treatment Plants, Volumes 1 and 2, 8th Edition
  • WEF Wastewater Treatment Fundamentals I: Liquid Treatment
  • WPI Wastewater Treatment and Collection Formula/Conversion Table (given to you at the exam)

What's on the exam

Official content outline from Water Professionals International (WPI) (number of questions per topic):

TopicQuestions
Equipment Evaluation, Maintenance, and Operation39
Treatment Process Evaluation and Adjustment38
Laboratory Analysis10
Security, Safety, and Administrative Procedures13

Exam day details

  • Administered by Water Professionals International (WPI) for Ohio EPA, at PSI test centers.
  • Fee: WPI's exam fee, paid to PSI when you schedule (check PSI for the current amount), plus Ohio EPA's $45 certification application fee after you pass.
  • 100 scored questions plus up to 10 unscored pretest questions in 3 hours. You need 70 to pass.
  • Ohio EPA now calls its wastewater treatment certificates "Water Reclamation". The Class I certificate uses WPI's standardized Wastewater Treatment Class I exam, and about 10 of the 100 questions are calculations.
  • Closed book. WPI provides its formula/conversion table, and you may bring a silent, non-programmable calculator.
  • Taken by computer at PSI test centers in Ohio (Cleveland, Cincinnati, Columbus, Akron, Cambridge, Troy and Toledo) or anywhere in the country.
  • You need a high school diploma or equivalent. If you pass before you have 12 months of operating experience, you become an operator in training and have up to 60 months to finish the experience.

Frequently asked questions

What's on the Ohio Class I wastewater exam?

100 scored questions from WPI's Wastewater Treatment Class I outline: equipment evaluation, maintenance and operation 39, treatment process evaluation and adjustment 38, security, safety and administrative procedures 13 and laboratory analysis 10.

What is a Water Reclamation certificate in Ohio?

It is Ohio EPA's current name for the wastewater treatment operator certificate. Ohio EPA's equivalency chart maps Water Reclamation Class I to WPI's Wastewater Treatment Class I exam.

How hard is the Ohio Class I wastewater exam?

On Ohio EPA's own May 2023 paper exam, 11 of 45 candidates (24%) passed Wastewater Class I. Most people now take the WPI computer exam, but plan on real study time.

Free questions with answers

Show all 10 free questions and answers
  1. What is the maximum holding time for a wastewater BOD sample kept at 6 C or colder?

    Answer: 48 hours

    Federal Table II allows 48 hours for BOD and CBOD samples cooled to 6 C or below. 15 minutes applies to pH, dissolved oxygen by probe and total residual chlorine, 8 hours to coliform bacteria, and 28 days to preserved ammonia.

    Reference: 40 CFR Part 136 (Test Procedures for the Analysis of Pollutants), 136.3(e), Table II (biochemical oxygen demand)

  2. A settleometer shows 260 mL/L of settled sludge after 30 minutes, and the MLSS is 2,000 mg/L. What is the sludge volume index (SVI)?

    Answer: 130 mL/g

    SVI = SSV30 (mL/L) x 1,000 / MLSS (mg/L) = 260 x 1,000 / 2,000 = 130 mL/g. An SVI around 50 to 150 usually means a well-settling sludge; much higher values point to bulking.

    Reference: WPI Wastewater Treatment/Collection Formula/Conversion Table, Sludge Volume Index, mL/g

  3. What is the most common deadly gas hazard in sewers, wet wells and enclosed wastewater spaces?

    Answer: Hydrogen sulfide

    Hydrogen sulfide forms when wastewater goes septic. It smells like rotten eggs at low levels but deadens the sense of smell at higher levels, so a gas monitor is the only reliable warning. It and methane are why confined spaces are tested before entry.

    Reference: 29 CFR 1910.146 (OSHA Permit-Required Confined Spaces), 1910.146 Appendix E, sewer system entry (atmospheric monitoring)

  4. Under the federal secondary treatment standard, what is the 30-day average limit for effluent BOD5?

    Answer: 30 mg/L

    Secondary treatment requires a 30-day average BOD5 of no more than 30 mg/L, a 7-day average no more than 45 mg/L, and at least 85% removal. If the permit uses CBOD5 instead, the limits are 25 and 40 mg/L.

    Reference: 40 CFR Part 133 (Secondary Treatment Regulation), 133.102(a)

  5. An aeration basin receives 1.2 MGD with a primary effluent BOD of 180 mg/L. The basin holds 0.4 MG at an MLVSS of 2,500 mg/L. What is the F/M ratio?

    Answer: 0.22

    F/M = lb BOD/day / lb MLVSS under aeration. Food = 1.2 x 180 x 8.34 = 1,801 lb/day. Microorganisms = 0.4 x 2,500 x 8.34 = 8,340 lb. F/M = 1,801 / 8,340 = 0.22. 4.6 inverts the ratio.

    Reference: WPI Wastewater Treatment/Collection Formula/Conversion Table, Food/Microorganism Ratio

  6. In the activated sludge process, what happens in the aeration tank?

    Answer: Bacteria use oxygen to convert dissolved and suspended waste into more bacteria

    The aeration tank is the biological step: aerobic bacteria consume cBOD and ammonia and grow into new cells. The clarifier then physically separates those bacteria from the water.

    Reference: Ohio EPA, Class A Training Manual for the Ohio Wastewater Treatment Certification Exam (2015), Basic Treatment Units: Secondary Stage

  7. Clumps of sludge are floating on the clarifier, and they sink when gently stirred. What is happening?

    Answer: Denitrification: nitrogen gas bubbles are lifting sludge held too long

    In the clarifier blanket, bacteria without oxygen convert nitrate to nitrogen gas. The bubbles float the sludge, and gentle agitation releases them so the solids sink again. The cure is to remove settled sludge faster, for example by scraping hopper walls and adjusting RAS.

    Reference: Ohio EPA, Class A Training Manual for the Ohio Wastewater Treatment Certification Exam (2015), Basic Treatment Units: Secondary Stage - Clarifier (denitrification)

  8. A submersible pump's control is set to AUTO. What turns the pump on and off?

    Answer: Float switches responding to the water level

    In AUTO the contactor is controlled by float switches: as the level rises the floats close the circuit and the pump runs, and as it falls they open it. Blowers, by contrast, usually run on time clocks.

    Reference: Ohio EPA, Class A Training Manual for the Ohio Wastewater Treatment Certification Exam (2015), Maintenance: Pumping Equipment, control panel

  9. A dosing tank is 4 ft in diameter. With no inflow, one pump lowers the level 2 ft in 1.5 minutes. What is the pumping rate?

    Answer: 125 gpm

    Area = 0.785 x 4 x 4 = 12.56 ft2. Volume pumped = 12.56 x 2 = 25.12 ft3 x 7.48 = 187.9 gal. Rate = 187.9 / 1.5 = 125 gpm. 188 gpm forgets to divide by the 1.5 minutes, 251 gpm divides by 0.75 minute instead of 1.5, and 16.7 gpm leaves out the 7.48 gal/ft3.

    Reference: Ohio EPA, Class A Training Manual for the Ohio Wastewater Treatment Certification Exam (2015), Controlling the Units: Tertiary Stage - Dosing Tank/Sand Filter (draw down test)

  10. Many package plants return sludge with an airlift pump. What drives an airlift?

    Answer: Compressed air injected into a pipe, lifting the water and sludge with it

    An airlift injects air near the bottom of a pipe; the lighter air-water mix rises and carries sludge up and over. Because it runs on blower air, RAS stops whenever the aeration timer turns the blower off, which affects timer settings.

    Reference: Ohio EPA, Class A Training Manual for the Ohio Wastewater Treatment Certification Exam (2015), Controlling the Units: Activated Sludge Process Control and Troubleshooting Chart, Box 6 (airlift return systems)

Sources

Questions last verified October 26, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.