National certification

Water Treatment Operator Class I Exam (WPI/ABC): Practice Test & Licensing Guide

The WPI (formerly ABC) standardized Water Treatment Operator Class I exam: 100 questions on treatment processes, lab tests, equipment, source water and safety.

Questions
100
Time limit
Not officially released
Passing score
70%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Treatment Process

A plant treating 2.5 MGD needs a chlorine dose of 3.0 mg/L and feeds calcium hypochlorite that is 65% available chlorine. How many pounds per day of calcium hypochlorite must be fed?

Requirements at a glance

ExamWater Treatment Class I: 100 scored questions, closed book, formula sheet provided
Colorado equivalentWater Treatment Class D
Passing scoreSet by your state; 70 in Colorado and most WPI states
Colorado fees$50 CDPHE application + $104 PSI exam

Entry-level drinking water treatment operators in states that use WPI exams, including Colorado Water Treatment Class D and Idaho Drinking Water Treatment Class I.

How to get certified, step by step

  1. Meet your state's eligibility rules

    Most states need a high school diploma or GED and some experience. In Colorado: the free regulatory course for your certificate type, plus one month of supervised experience for Class D or 1.

    CDPHE: which certificate is right for you (opens in a new tab)

  2. Apply to your certifying agency

    Apply to your state program (in Colorado, CDPHE's Certified Water Professionals program). Once approved, you get instructions to schedule with PSI.

    CDPHE: steps to becoming certified (Colorado) (opens in a new tab)

  3. Take the exam

    At a PSI test center or by remote proctoring. WPI's formula/conversion sheet is provided; bring a basic calculator.

  4. Get certified

    Your state issues the certificate after you pass. Higher classes need more experience and the next exam level.

How to prepare

  • Learn the formula sheet before exam day: know which formula each problem needs and practice unit conversions (gallons, cubic feet, pounds, psi, feet of head).
  • Treatment process is 31 questions: coagulation, flocculation, sedimentation, filtration and disinfection (CT, chlorine dose = demand + residual).
  • Practice dosage (lb/day = mg/L × MGD × 8.34) and detention time problems.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

Official reference list (as published by the testing agency)
  • WPI formula/conversion sheet (provided at the exam)
  • 40 CFR Parts 141 and 143 (Safe Drinking Water Act rules) and 40 CFR Part 503 (biosolids)
  • 29 CFR 1910 and 1926 (OSHA safety)

What's on the exam

Official content outline from Water Professionals International (WPI, formerly ABC); delivered by PSI (number of questions per topic):

TopicQuestions
Treatment Process31
Laboratory Analysis16
Equipment Operation and Maintenance26
Source Water Characteristics15
Security, Safety and Administrative Procedures12

Exam day details

  • Administered by Water Professionals International (WPI, formerly ABC); delivered by PSI for most states.
  • Fee: Set by your state. In Colorado: $104 to PSI plus a $50 CDPHE application fee.
  • 100 scored questions, about 10 of them calculations.
  • Up to 10 extra unscored pretest questions are mixed in.
  • Passing is set by your state; Colorado and most WPI states use 70. WPI's 2025 exams are reported as scaled scores.
  • WPI's formula/conversion sheet is provided; bring a basic non-programmable calculator.
  • Time is set by the state and PSI (typically 3 hours for a 100-question exam); PSI confirms it when you schedule.
  • Colorado: Class D/1 = WPI Class I up to Class A/4 = Class IV. You need a high school diploma or GED and Colorado's free regulatory course.

Frequently asked questions

Which Colorado certificate uses the Water Treatment Class I exam?

Colorado Water Treatment Class D. Class C, B and A use WPI Class II, III and IV.

What's on the Water Treatment Class I exam?

Treatment processes such as coagulation, filtration and disinfection (31), equipment operation and maintenance (26), lab analysis (16), source water (15) and safety and administration (12).

Does Idaho use this exam?

Idaho operators are licensed by DOPL's Board of Drinking Water and Wastewater Professionals in Classes I to IV, and Idaho's operator exams are ABC (now WPI) exams. Idaho's Class I matches WPI Class I. Check with DOPL for the current application and exam steps.

Free questions with answers

Show all 10 free questions and answers
  1. A plant treating 2.5 MGD needs a chlorine dose of 3.0 mg/L and feeds calcium hypochlorite that is 65% available chlorine. How many pounds per day of calcium hypochlorite must be fed?

    Answer: 96.2 lb/day

    Use the formula sheet's feed-rate equation: lb/day = (dose, mg/L)(flow, MGD)(8.34 lb/gal) / purity as a decimal. Pure chlorine needed = 3.0 × 2.5 × 8.34 = 62.55 lb/day, and 62.55 / 0.65 = 96.2 lb/day of 65% product. 62.6 lb/day ignores the purity. 40.7 lb/day multiplies by 0.65 instead of dividing, which would underdose. 15.4 lb/day divides by the flow instead of multiplying.

    Reference: WPI Formula/Conversion Table, Water Treatment, Distribution & Laboratory (2024), Feed Rate, lb/day (with purity)

  2. Raw water containing some ammonia is being chlorinated. Once the dose has passed the breakpoint, what happens when more chlorine is added?

    Answer: The added chlorine shows up as free chlorine residual

    Before the breakpoint, chlorine first meets demand, then forms chloramines (combined residual), and then destroys those chloramines so the residual dips. At the breakpoint the destructible chloramines are gone, and from there each added unit of chlorine appears as free available chlorine, so the free residual rises with the dose. A falling combined residual describes the zone just before the breakpoint, not after it. Forming chloramines happens on the rising limb at low doses.

    Reference: New Mexico Water Systems Operator Certification Study Manual (NMED, Version IV, 2011), Chapter 5: Disinfection, Breakpoint Chlorination

  3. A filter shows unusually high head loss right after it is returned to service from a backwash, and bubbles rise through the media when it is next washed. What is the most likely problem?

    Answer: Air binding of the filter media

    Air binding happens when dissolved air comes out of solution in the bed, often after a filter is run to very high head loss. The trapped air blocks part of the media, so head loss is high even when the bed is clean, and the remaining media is overloaded. Mud balls build up slowly from poor backwashing, while a low coagulant dose and breakthrough show up as high effluent turbidity rather than high clean-bed head loss.

    Reference: New Mexico Water Systems Operator Certification Study Manual (NMED, Version IV, 2011), Chapter 12: Surface Water, Troubleshooting Filter Problems (Air Binding)

  4. In a deep reservoir, iron and manganese levels are usually highest in which zone?

    Answer: Near the bottom, where dissolved oxygen is low

    Low dissolved oxygen near a lake's bottom keeps iron and manganese in their dissolved, reduced form, so concentrations are highest there. Near the surface, oxygen from wind and algae oxidizes the metals so they precipitate. That is why moving the intake to a higher level is often the cheapest way to reduce iron and manganese entering the plant.

    Reference: New Mexico Water Systems Operator Certification Study Manual (NMED, Version IV, 2011), Chapter 12: Surface Water, Lakes and Rivers

  5. How soon after collection must a chlorine residual sample be analyzed?

    Answer: Within 15 minutes, essentially at the sampling point

    Chlorine residual is not stable: it reacts with the sample, the container and light, so the federal holding-time table calls for analysis within 15 minutes, which in practice means testing at the tap. Refrigeration or keeping it dark does not stop the loss. Sodium thiosulfate destroys chlorine, so it would make a residual test meaningless; it is used in bacteriological bottles for that reason.

    Reference: 40 CFR Part 136, 40 CFR 136.3(e), Table II (Chlorine, total residual: analyze within 15 minutes)

  6. Where should the exhaust ventilation intake be located in a gas chlorine feed room, and why?

    Answer: Near the floor, because chlorine gas is heavier than air

    Chlorine gas is about 2.5 times heavier than air, so leaked gas sinks and collects in low spots. Exhaust pickups go near the floor, with light and fan switches outside the room so the room can be ventilated for several minutes before anyone enters. A ceiling vent would leave the heaviest concentration of gas where operators breathe and work.

    Reference: New Mexico Water Systems Operator Certification Study Manual (NMED, Version IV, 2011), Chapter 5: Disinfection, Chlorinator Room

  7. A three-phase pump motor was rewired and now runs backward. How is the rotation reversed?

    Answer: Swap any two of the three power leads

    A three-phase motor has no start circuit; its direction is set by the phase sequence of the three supply leads. Interchanging any two leads reverses the rotating magnetic field and the motor's direction. Start capacitors belong to single-phase motors, and the ground wire carries no load current. This work must be done by a qualified electrician with the circuit locked out.

    Reference: New Mexico Water Systems Operator Certification Study Manual (NMED, Version IV, 2011), Chapter 9: Pumps & Motors, Three Phase Motors

  8. A surface water plant with high natural organic matter prechlorinates at the intake, and its TTHM results are near the MCL. Which change is most likely to lower TTHMs?

    Answer: Move chlorine addition downstream, after coagulation removes organics

    Trihalomethanes form when free chlorine reacts with natural organic matter, and the reaction grows with dose, contact time and pH. Removing the organic precursors by coagulation, settling and filtration before adding chlorine cuts TTHM formation sharply. More chlorine makes more TTHMs, and higher pH increases THM formation. Longer free chlorine contact before the organics are removed gives more time for THMs to form.

    Reference: 40 CFR Part 141, Subpart L, 40 CFR 141.64(b) (TTHM MCL 0.080 mg/L); 40 CFR 141.135 (enhanced coagulation)

  9. A main break drops the pressure in part of the system below atmospheric, and water is drawn back from a hose left submerged in a tank. What type of backflow is this?

    Answer: Backsiphonage

    Backsiphonage occurs when supply pressure drops below atmospheric and pulls water backward from a source open to the atmosphere, such as a submerged hose. Backpressure is when a downstream source, like a boiler or booster pump, is at higher pressure than the supply and pushes water back. Water hammer is a pressure surge, not a reversal of flow.

    Reference: New Mexico Water Systems Operator Certification Study Manual (NMED, Version IV, 2011), Chapter 7: Distribution, Backflow

  10. A pump delivers 800 gpm against a total dynamic head of 120 ft. If the pump is 75% efficient, what brake horsepower is required?

    Answer: 32.3 hp

    Brake hp = (flow, gpm)(head, ft) ÷ [3,960 × pump efficiency]. Water hp = 800 × 120 ÷ 3,960 = 24.2 hp; dividing by 0.75 gives 32.3 hp. 24.2 hp is water horsepower with no efficiency loss. 18.2 hp multiplies by 0.75 instead of dividing, and 43.1 hp divides by 0.75 twice as if it were also the motor efficiency.

    Reference: WPI Formula/Conversion Table, Water Treatment, Distribution & Laboratory (2024), Horsepower, Brake, hp

Sources

Questions last verified October 21, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.