Ohio Refrigeration Contractor Exam: Practice Test & Licensing Guide

The PSI trade exam for Ohio's commercial refrigeration contractor license: 60 questions on refrigerants, piping, systems and controls, and testing, with the Ohio Mechanical Code open book.

Questions
60
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Refrigeration Systems and Controls

One condensing unit serves a 35°F cooler evaporator and a -10°F freezer evaporator. Which device keeps the cooler evaporator from running too cold when the compressor pulls down suction pressure for the freezer?

Requirements at a glance

AgencyOhio Construction Industry Licensing Board (OCILB); exams by PSI
ExperienceAt least 5 years as a tradesperson in the trade immediately before you apply (registered engineers can qualify with 3 years of construction business experience)
Exams60 questions, 3 hours, 70%, plus the Contractor's Business and Law exam
Books allowed2024 Ohio Mechanical Code and Modern Refrigeration and Air Conditioning
Fees$69 per PSI exam, plus OCILB application and license fees and contractor's liability insurance

Qualifying individuals for an Ohio commercial refrigeration contractor license (food and product preservation systems, not comfort cooling) from the OCILB.

How to get licensed, step by step

  1. Confirm you qualify

    You must be 18, a U.S. citizen or legal resident, and have 5 years in the trade. The OCILB also checks your conduct record.

    Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)Ohio Revised Code Chapter 4740 (OCILB) (opens in a new tab)

  2. Apply to the OCILB

    Send the exam application and fee to the OCILB. When it approves you, get a state (BCI) and federal (FBI) background check before you sit. Approval is good for one year.

    Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)

  3. Schedule the Business and Law exam and the refrigeration exam with PSI

    Book both exams with PSI ($69 each). If you fail, wait 60 days; you can test up to 5 times in a year. Pass the business and law exam once and it covers any other trade licenses you add for three years.

    Schedule with PSI (Ohio contractors) (opens in a new tab)PSI: Ohio contractor trade exam bulletin and outlines (opens in a new tab)

  4. Get insured and licensed

    After you pass both exams, send the OCILB your results, the license fee and proof of contractor's liability insurance. Licenses renew every year with 10 hours of continuing education.

    Ohio Construction Industry Licensing Board (OCILB) (opens in a new tab)

How to prepare

  • Bring the exact editions on PSI's outline. Ohio's code books are the 2024 Ohio Plumbing Code and Ohio Mechanical Code (the 2021 IPC and IMC with Ohio amendments) and the 2023 NEC.
  • Tab your books before exam day. You can highlight, underline and index them, but you can't write in them or add loose papers.
  • Ohio's licenses are for commercial work. Residential work is handled by local jurisdictions, so questions stay on commercial buildings.
  • General knowledge and requirements (18) and systems and controls (15) are more than half the exam. Know the refrigeration cycle, superheat and subcooling.
  • Tab IMC Chapter 11: refrigerant classification, machinery rooms, piping and pressure testing.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the Ohio Mechanical Code and Modern Refrigeration and Air Conditioning. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • Ohio Mechanical Code, 2024, based on the 2021 International Mechanical Code (allowed in the exam room)
  • Modern Refrigeration and Air Conditioning, 22nd Edition, Goodheart-Willcox (allowed in the exam room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
General Knowledge and Requirements18
Refrigeration Piping12
Refrigerants6
Refrigeration Systems and Controls15
Testing and Inspection9

Exam day details

  • Administered by PSI Services for the Ohio Construction Industry Licensing Board (OCILB).
  • Fee: $69 to PSI per exam. OCILB application and license fees are separate.
  • 60 scored questions plus 10 unscored pretest items in 3 hours; 42 correct (70%) to pass.
  • Ohio refrigeration licenses cover systems for food and product preservation, with no limit on tons or horsepower. Comfort cooling falls under the HVAC license.
  • Open book: bring your own copies of the allowed references. You may highlight, underline and index them beforehand, but not write in them.
  • PSI may add unscored pretest questions, which count against your time.
  • If you fail an exam, wait 60 days to retest. You can test up to 5 times in a year.
  • The OCILB must approve your application first and you need a state and federal background check before you sit. Approval is good for one year.
  • Every commercial trade license also needs the Contractor's Business and Law exam, which you pass once every three years however many trade licenses you add.

Frequently asked questions

What's on the Ohio refrigeration contractor exam?

60 scored questions: general knowledge and requirements 18, refrigeration systems and controls 15, refrigeration piping 12, testing and inspection 9 and refrigerants 6.

Which books are allowed on the Ohio refrigeration exam?

The Ohio Mechanical Code (2024) and Modern Refrigeration and Air Conditioning (22nd edition).

Do I need EPA 608 certification as well?

Federal law requires EPA Section 608 certification to handle refrigerants, but it is separate from the OCILB exam.

Free questions with answers

Show all 10 free questions and answers
  1. One condensing unit serves a 35°F cooler evaporator and a -10°F freezer evaporator. Which device keeps the cooler evaporator from running too cold when the compressor pulls down suction pressure for the freezer?

    Answer: An evaporator pressure regulator in the cooler evaporator's suction line

    In a multiple-temperature system, an evaporator pressure regulator (EPR) goes in the suction line of the warmer evaporator. It holds that coil's pressure, and so its saturation temperature, at or above the setting no matter how low common suction falls. The freezer runs at the lowest pressure and needs no EPR. A crankcase pressure regulator protects the motor and is a different device.

    Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 46: Commercial Refrigeration System Configurations

  2. A walk-in cooler uses a pump-down cycle. When the box thermostat is satisfied, what does it de-energize?

    Answer: The liquid line solenoid valve

    In a pump-down cycle the thermostat controls the liquid line solenoid, not the compressor. When the solenoid closes the compressor keeps running and pumps refrigerant out of the evaporator into the condenser and receiver until the low-pressure control stops it. This keeps liquid from migrating to the crankcase during the off cycle.

    Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 45: Commercial Metering Devices and Valves

  3. Table 1103.1 classifies refrigerants by ASHRAE 34 safety group. Which refrigerant is classified A1?

    Answer: R-404A

    Table 1103.1 lists R-22, R-134a, R-404A, R-407C, R-410A and R-507A as Group A1 (lower toxicity, no flame propagation). R-290 and R-600a are Group A3 (higher flammability), and R-32 is listed in the A2 flammability group.

    Reference: 2024 Ohio Mechanical Code (2021 IMC with Ohio amendments), Table 1103.1

  4. A recovery cylinder is being filled with liquid refrigerant. To what level may it be filled at most?

    Answer: 80 percent of its liquid capacity

    Recovery cylinders are filled to no more than 80 percent so there is vapor space for liquid expansion as temperature rises. A liquid-filled cylinder can build pressure fast enough to burst as it warms.

    Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 11: Equipment and Instruments for Refrigerant Handling and Service

  5. Soft annealed copper tubing larger than 1-3/8 inch O.D. may be used for field-assembled refrigerant piping only if:

    Answer: It is protected from mechanical damage

    Footnote a to Table 1107.4 states that soft annealed copper tubing larger than 1-3/8 inch O.D. shall not be used for field-assembled refrigerant piping unless it is protected from mechanical damage.

    Reference: 2024 Ohio Mechanical Code (2021 IMC with Ohio amendments), Table 1107.4, footnote a

  6. A rack compressor unloads to 25 percent capacity. A single suction riser sized for full load would have too little velocity to carry oil at minimum load. What is the usual solution?

    Answer: A double riser: a small one for low load and a larger trapped one

    A double riser uses two parallel risers. At full load vapor flows through both. At low load oil collects in the trap at the base of the larger riser and seals it, so all vapor goes through the smaller riser at a velocity high enough to carry oil.

    Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 52: Commercial Refrigeration Component Selection

  7. A low-temperature condensing unit reads 190 psig discharge and 12 psig suction at sea level. What is the compression ratio, using absolute pressures?

    Answer: 7.7 to 1

    Compression ratio uses absolute pressure. Discharge = 190 + 14.7 = 204.7 psia and suction = 12 + 14.7 = 26.7 psia. Ratio = 204.7 ÷ 26.7 = 7.67, about 7.7 to 1. Dividing the gauge readings (190 ÷ 12) gives 15.8 to 1, a common mistake.

    Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 7: Gases

  8. A technician must enter a walk-in cooler after a large leak of a fluorocarbon refrigerant. What is the main hazard?

    Answer: Suffocation, since the heavier-than-air vapor displaces oxygen near the floor

    Most fluorocarbon refrigerants are heavier than air and collect in low, enclosed spaces, displacing oxygen. A person entering can lose consciousness with little warning, so the space should be ventilated and checked before entry.

    Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 2: Safety

  9. Field-assembled refrigerant tubing not exceeding 5/8 inch outside diameter is being pressure tested. Which test medium is permitted besides inert gases?

    Answer: The refrigerant identified on the nameplate label or marking

    Section 1110.3 allows oxygen-free nitrogen, helium or argon as the test medium, and permits systems erected on the premises with tubing not exceeding 5/8 inch O.D. to use the refrigerant on the nameplate. Oxygen, air, combustible gases and mixtures containing them are prohibited.

    Reference: 2024 Ohio Mechanical Code (2021 IMC with Ohio amendments), 1110.3

  10. A condensing unit's pressure converts to a saturation temperature of 112°F, and the liquid line temperature leaving the receiver is 101°F. What is the subcooling?

    Answer: 11°F

    Subcooling = saturated condensing temperature − actual liquid line temperature = 112 − 101 = 11°F.

    Reference: Modern Refrigeration and Air Conditioning, 22nd Edition, Chapter 12: Working with Refrigerants

Sources

Questions last verified October 25, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.