Ohio High-Pressure Boiler Operator Exam: Practice Test & Licensing Guide

The PSI exam for Ohio's high-pressure boiler operator license (steam boilers over 15 psi): 40 questions on boiler design, construction, combustion, indicators and devices, operation, pumps, auxiliaries and emissions. Closed book.

Questions
40
Time limit
3 hours
Passing score
70%
Books
Closed book
What to study ↓

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Boilers: Steam Cycle

In a basic steam plant cycle, where does the condensate go after the steam gives up its heat at the end users?

Requirements at a glance

AgencyOhio Division of Industrial Compliance; exam by PSI
Experience2,000 hours on a steam boiler over 15 psi; or 700 hours plus a 75-hour approved course; or a low-pressure license plus 400 hours and the 75-hour course
Exam40 questions, 3 hours, 70% to pass, closed book; calculator allowed
Fees$25 application, $100 PSI exam fee, $72 license (renews yearly at $72)

People who operate steam boilers over 15 psi in Ohio. You need 2,000 hours operating a high-pressure steam boiler, 700 hours plus a 75-hour approved course, or a low-pressure license plus 400 hours and the 75-hour course.

How to get licensed, step by step

  1. Document your hours

    Gather an employment history report or an hours-worked statement from your employer, any course certificate and the boiler's nameplate or state ID.

    Ohio Commerce: boiler operator and steam engineer licenses (opens in a new tab)

  2. Apply to the Division

    Submit the signed, notarized exam application and the $25 fee through the IC Customer Portal (you need an OHID).

    Ohio Commerce: boiler operator and steam engineer licenses (opens in a new tab)

  3. Take the PSI exam

    Once approved, the Division registers you with PSI. The high-pressure exam is closed book; you need 70% to pass and can retake as needed ($100 each time).

    PSI: Ohio steam engineer/boiler operator bulletin (opens in a new tab)

  4. Get licensed and renew yearly

    Pay the $72 license fee after you pass. Licenses expire every year; renew online before the expiration date.

    Ohio Commerce: boiler operator and steam engineer licenses (opens in a new tab)

How to prepare

  • Boiler design (9), boiler operation (7) and auxiliary equipment (7) are more than half the exam: fire-tube versus water-tube, economizers, deaerators, feed pumps and blowdown.
  • PSI writes the questions from Steam Plant Operation (10th ed.) and High Pressure Boilers (5th ed.), and neither is allowed in the room, so study them ahead of time.
  • Know Ohio's rules too: 360 sq ft of heating surface triggers licensing, continuous attendance is the default, and safety valves can't be set above the certificate.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

What to study

This is a closed-book exam, so nothing comes into the exam room. Study from these:

Official reference list (as published by the testing agency)
  • Steam Plant Operation, 10th Edition (2017), Woodruff, Lammers and Lammers, McGraw-Hill (not allowed in the exam room)
  • High Pressure Boilers, 5th Edition (2012), Steingress and Frost, American Technical Publishers (not allowed in the exam room)
  • Ohio Revised Code Chapter 4104 and Ohio Administrative Code Chapter 4101:4 (boilers)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Boilers: Steam Cycle1
Boiler Design9
Boiler Construction2
Combustion: Fuels1
Combustion: Equipment4
Boiler Indicators and Devices5
Boiler Operation7
Pumps2
Boiler Auxiliary Support Equipment7
Environmental Control2

Exam day details

  • Administered by PSI Services for the Ohio Division of Industrial Compliance.
  • Fee: $100 to PSI, plus the Division's $25 application fee and $72 license fee.
  • 40 questions in 3 hours; 28 correct (70%) to pass. PSI may add a few unscored experimental questions.
  • Closed book. You may bring a silent, non-printing, non-programmable calculator.
  • The license covers high-pressure and low-pressure boilers. Steam turbines over 30 hp need the separate stationary steam engineer license.
  • Apply to the Division of Industrial Compliance first ($25, signed and notarized, through the IC Customer Portal). Once approved, the Division registers you with PSI.
  • The PSI fee is $100 per attempt and you can retake as many times as needed. Licenses cost $72 and renew every year.

Frequently asked questions

What's on the Ohio high-pressure boiler exam?

40 questions: boiler design 9, boiler operation 7, auxiliary support equipment 7, indicators and devices 5, combustion equipment 4, boiler construction 2, pumps 2, environmental control 2, the steam cycle 1 and fuels 1.

Which books should I study for the Ohio high-pressure boiler exam?

PSI wrote the questions from Steam Plant Operation (10th edition) and High Pressure Boilers (5th edition). Neither book is allowed in the exam room.

Does a high-pressure license cover low-pressure boilers?

Yes. The high-pressure exam covers high- and low-pressure boilers, and the license lets you operate both.

Free questions with answers

Show all 10 free questions and answers
  1. In a basic steam plant cycle, where does the condensate go after the steam gives up its heat at the end users?

    Answer: Back through the return system to the feedwater tank or deaerator

    After steam condenses in heat exchangers or other end uses, traps pass the condensate into the return system, which sends it back to a collection tank or the deaerator to become feedwater again. Returning condensate saves water, heat and treatment chemicals.

    Reference: U.S. DOE, Improving Steam System Performance: A Sourcebook for Industry, 2nd Edition, Steam system basics (generation, distribution, end use, recovery)

  2. In a fire-tube boiler, where are the hot combustion gases?

    Answer: Inside the tubes, with water surrounding them

    In a fire-tube boiler, combustion gases pass through the tubes while water surrounds them. In a water-tube boiler the arrangement is reversed: water is inside the tubes and gases flow around them.

    Reference: TM 5-642, Operation and Maintenance: Small Heating Systems (Department of the Army, 1990), Par. 4-8, steel boilers

  3. What does an economizer do?

    Answer: Heats boiler feedwater using heat from the flue gas

    An economizer raises feedwater temperature while lowering flue gas temperature. As a rule of thumb, boiler efficiency rises about 2.5 percent for each 100 F drop in exit gas temperature.

    Reference: UFC 3-430-02FA / TM 5-810-15, Central Steam Boiler Plants (2003), Par. 3-16d, economizers

  4. What is the purpose of the pre-ignition purge on a gas or oil fired boiler?

    Answer: To clear any combustible gases from the furnace before the ignitor lights

    A purge passes air through the furnace and flues to remove any fuel or combustible gas that may have collected, so lighting off can't cause an explosion. The central plant manual describes a purge of at least 25 to 30 percent air flow for five minutes.

    Reference: UFC 3-430-02FA / TM 5-810-15, Central Steam Boiler Plants (2003), Par. 9-3a, furnace safety system

  5. Which valve does the DOE sourcebook call the most important valve on the boiler?

    Answer: The safety valve

    The safety valve is the most important valve on the boiler because it keeps the boiler from exceeding its maximum allowable working pressure (MAWP).

    Reference: U.S. DOE, Improving Steam System Performance: A Sourcebook for Industry, 2nd Edition, Steam system basics: boiler controls (safety valve)

  6. What is the most serious situation that can occur in a boiler plant, according to TM 5-642?

    Answer: Low water level

    TM 5-642 calls low water level the most serious situation in a boiler plant, because it can overheat and damage the boiler. Automatic feeders should not be depended on alone.

    Reference: TM 5-642, Operation and Maintenance: Small Heating Systems (Department of the Army, 1990), Par. 4-78, low water level

  7. A boiler makes 30,000 lb/hr of steam. Feedwater has 150 ppm dissolved solids, and the boiler water is to be held at 2,500 ppm. Using R = B x Q / (A - B), what continuous blowdown rate is needed?

    Answer: About 1,915 lb/hr

    R = feedwater solids x steam flow / (boiler water limit - feedwater solids) = 150 x 30,000 / (2,500 - 150) = 4,500,000 / 2,350 = 1,915 lb/hr. 1,800 lb/hr divides by 2,500 without subtracting the feedwater solids.

    Reference: UFC 3-430-02FA / TM 5-810-15, Central Steam Boiler Plants (2003), Par. 7-8b(1), equation 7-2 (continuous blowdown rate)

  8. Why is the deaerator usually mounted high above the boiler feed pumps?

    Answer: To give the pumps enough suction head (NPSH) so saturated water doesn't flash and cavitate

    Feed pumps take water from the deaerator at saturation, so the deaerator is elevated to add static head at the pump suction and overcome the vapor pressure. NPSH available is essentially the water head from the deaerator to the pump inlet minus friction loss.

    Reference: UFC 3-430-02FA / TM 5-810-15, Central Steam Boiler Plants (2003), Par. 7-4d(1), calculation of net positive suction head available

  9. What does a blowdown tank do?

    Answer: Lets hot blowdown water flash to steam so the concentrated water can be drained safely

    A blowdown tank allows the hot water to flash to steam, leaving the concentrated impurities to be drained to waste more safely. The flash steam can be vented or used for heat recovery.

    Reference: UFC 3-430-02FA / TM 5-810-15, Central Steam Boiler Plants (2003), Par. 7-8a, blowdown tank (application)

  10. Which three types of particulate control systems does the central plant manual list as commonly used?

    Answer: Mechanical cyclone collectors, fabric filter baghouses and electrostatic precipitators

    Particulate (fly ash) is commonly removed with mechanical cyclone collectors, fabric filter baghouses and electrostatic precipitators. SCR and SNCR control NOx, and wet or dry FGD systems remove sulfur oxides.

    Reference: UFC 3-430-02FA / TM 5-810-15, Central Steam Boiler Plants (2003), Par. 4-2, particulate control systems