Requirements at a glance
| Agency | NC Licensing Board for General Contractors (NCLBGC); exams by PSI |
|---|---|
| When you need a license | Projects of $40,000 or more (G.S. 87-1). Limited up to $750,000, Intermediate up to $1,500,000, Unlimited no cap. |
| Exam | Building Contractor exam, 90 questions in 200 minutes, open book, 70% to pass |
| Books allowed | 2018 NC Building Code and Administrative Code, ACI 318, ACI 530, ANSI A117.1-2017, Sports Fields (2010), NASCLA NC guide, NC OSHA |
| Fees | $79 per PSI exam, plus the Board's application and license fees |
Anyone qualifying a Building general contractor license from the NC Licensing Board for General Contractors (commercial, industrial, institutional and residential building, $40,000 or more).
Official links
How to get licensed, step by step
Apply to the Board
Send the license application or examination request form to the NCLBGC (5400 Creedmoor Road, Raleigh; 919-571-4183). Applicants must be 18 with good moral character and financial responsibility.
NC Licensing Board for General Contractors (NCLBGC) (opens in a new tab)
Get your eligibility letter
The Board approves you and sends an eligibility letter with your state ID number. It is good for 120 days and one exam.
Schedule with PSI (NC general contractors) (opens in a new tab)
Schedule with PSI
Book and pay ($79) at PSI online or at 855-746-8173. If you fail you can retake as often as you like within 12 months while your application stays valid.
Schedule with PSI (NC general contractors) (opens in a new tab)
Finish licensing
After you pass, the Board completes your license. A classification (Building, Residential, Highway, Public Utilities or Specialty) and a limitation (Limited, Intermediate, Unlimited) go on it.
NC Licensing Board for General Contractors (NCLBGC) (opens in a new tab)
How to prepare
- North Carolina's exams use the 2018 NC State Building Code (2015 ICC base text with NC amendments, effective 2019). The 2024 NC codes are delayed to no earlier than May 1, 2027, so use the 2018 books.
- Tab your books with permanent tabs before exam day. Highlighting is allowed; writing, sticky flags and loose papers are not.
- Concrete (13) and metals (12) are the biggest trade topics; tab ACI 318 and the NC Building Code chapters on structural steel and concrete.
- Sports fields (5) has its own textbook: read the grading, drainage and turf chapters.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2018 NC Building Code and the NASCLA NC guide. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2018 North Carolina State Building Code: Building CodeEssential
Allowed in the exam room. The 2015 IBC with NC amendments; the base of the Building exam.
2018 North Carolina State Building Code: Administrative Code and Policies
Allowed in the exam room for the general contractor, plumbing and heating exams.
Contractor's Guide to Business, Law and Project Management, North Carolina General Contractors Edition, 10th Edition (NASCLA)Essential
Allowed in the exam room. Most business, law and licensing questions are written from it.
NASCLA store: Maryland Home Improvement Commission edition (opens in a new tab)
North Carolina Occupational Safety and Health Standards for the Construction Industry
Allowed in the exam room for the Building and Residential exams. Source of the safety questions.
Official reference list (as published by the testing agency)
- North Carolina State Building Code: Building Code, 2018 (2015 IBC with NC amendments)
- North Carolina State Building Code: Administrative Code and Policies, 2018
- ACI 318-11 or ACI 318-14: Building Code Requirements for Structural Concrete
- ACI 530/530.1-11 or -13: Building Code Requirements and Specification for Masonry Structures
- ANSI A117.1-2017: Accessible and Usable Buildings and Facilities
- Sports Fields: Design, Construction and Maintenance, Second Edition, 2010 (Wiley)
- Contractor's Guide to Business, Law and Project Management, North Carolina General Contractors Edition, 10th Edition (NASCLA)
- North Carolina Occupational Safety and Health Standards for the Construction Industry, with latest amendments
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Site Work | 6 | |
| Concrete | 13 | |
| Masonry | 6 | |
| Metals | 12 | |
| Carpentry | 7 | |
| Roofing | 6 | |
| Associated Trades | 3 | |
| Business and Law | 7 | |
| Safety | 4 | |
| Estimating, Plan Reading and General Building Code Requirements | 14 | |
| One Call | 2 | |
| Erosion and Sedimentation Control | 2 | |
| Licensing | 2 | |
| Liens | 1 | |
| Sports Fields | 5 |
Exam day details
- Administered by PSI Services for the NC Licensing Board for General Contractors.
- Fee: $79 per exam to PSI, nonrefundable. NCLBGC application and license fees are separate.
- 90 questions in 200 minutes; 63 correct (70%) to pass.
- Code questions are based only on the 2018 NC codes and the ACI and ANSI editions listed. The 2024 NC codes are delayed and no earlier than May 1, 2027.
- The Building classification covers all building construction (commercial, industrial, institutional and residential), parking decks, site work, paving, storm drainage and recreational facilities including athletic fields, plus the S(Concrete), S(Insulation), S(Interior Construction), S(Marine), S(Masonry), S(Roofing), S(Metal Erection), S(Swimming Pools) and S(Asbestos) specialties.
- Open book: bring your own bound copies of the allowed references. You may highlight, underline and index them with permanent tabs, but not write in them. Sticky flags are not allowed. Code books are the only references that may be copied and bound.
- PSI may add 5 to 10 unscored experimental questions. Their time does not count against your exam time.
- The Board approves your application first and sends an eligibility letter with your state ID number. The letter is good for 120 days and one exam; a no-show counts as an attempt.
- If you fail, you may retake as many times as you like within 12 months as long as the information in your application stays valid. Each attempt costs the exam fee.
- A silent, non-printing, non-programmable calculator is allowed.
Frequently asked questions
What's on the North Carolina Building contractor exam?
90 questions: estimating, plan reading and general building code requirements 14, concrete 13, metals 12, business and law 7, carpentry 7, site work 6, masonry 6, roofing 6, sports fields 5, safety 4, associated trades 3, and one call, erosion control and licensing 2 each, liens 1.
Which books does the Building exam use?
The 2018 NC Building Code and Administrative Code, ACI 318 and ACI 530 (2011 or later editions listed), ANSI A117.1-2017, Sports Fields (2010), the NASCLA NC guide and the NC OSHA construction standards.
Is there a separate business and law exam?
Yes. The NC GC Business and Law exam is a separate 40-question PSI exam; see its exam page.
Free questions with answers
Show all 10 free questions and answers
What is the minimum thickness the code allows for a concrete floor slab supported directly on the ground?
Answer: 3 1/2 inches
Section 1907.1 sets the minimum thickness of slabs supported directly on the ground at 3 1/2 inches. Slabs thinner than that are not permitted under the minimum slab provisions, and the 4 1/2-inch figure is not a code minimum for this case.
Reference: 2018 North Carolina Building Code (2015 IBC base), Section 1907.1
A masonry fireplace has a firebox lined with 2-inch firebrick. What is the minimum total thickness of the back and side walls, including the lining?
Answer: 8 inches of solid masonry
Section 2111.6 requires back and side walls of 8 inches of solid masonry, including the lining, when firebrick at least 2 inches thick is provided. With no lining, the walls must be 10 inches of solid masonry.
Reference: 2018 North Carolina Building Code (2015 IBC base), Section 2111.6
Which specifications does Section 2207.1 name for the design, manufacture and use of open-web steel joists and joist girders?
Answer: Steel Joist Institute (SJI) specifications
Section 2207.1 lists SJI CJ, SJI K, SJI LH/DLH and SJI JG for open-web steel joists and joist girders. AISC 360 covers structural steel shapes and AISI covers cold-formed members.
Reference: 2018 North Carolina Building Code (2015 IBC base), Section 2207.1
How many floors plus a roof may wood walls and bearing partitions support without a shrinkage analysis satisfactory to the building official?
Answer: Two floors and a roof
Section 2304.3.3 limits wood walls and bearing partitions to supporting two floors and a roof unless an analysis shows shrinkage will not harm the structure or its plumbing, electrical and mechanical systems or the roof drainage.
Reference: 2018 North Carolina Building Code (2015 IBC base), Section 2304.3.3
What is the minimum slope for a standing-seam metal roof panel system, and for lapped, nonsoldered panels without sealant?
Answer: 1/4:12 for standing seam; 3:12 for lapped nonsoldered panels without sealant
Section 1507.4.2 sets 3:12 for lapped, nonsoldered seams without sealant, 1/2:12 with applied lap sealant, and 1/4:12 for standing-seam systems.
Reference: 2018 North Carolina Building Code (2015 IBC base), Section 1507.4.2
After backfilling around a foundation, what slope must the ground have away from the building, and for what minimum distance, under the standard site grading rule?
Answer: 1 unit vertical in 20 horizontal (5 percent) for at least 10 feet
Section 1804.4 requires the ground next to the foundation to slope away at not less than 5 percent for at least 10 feet, measured perpendicular to the wall. The 2 percent slope applies only where the exception for climatic or soil conditions is invoked.
Reference: 2018 North Carolina Building Code (2015 IBC base), Section 1804.4
What is the minimum height of a construction railing used to direct pedestrians around a work area?
Answer: 42 inches
Section 3306.4 requires construction railings at least 42 inches high. Barriers (Section 3306.5) must be at least 8 feet high.
Reference: 2018 North Carolina Building Code (2015 IBC base), Section 3306.4
A 40-foot by 60-foot slab on grade is to be 4 inches thick. Allowing 10 percent for waste and spillage, about how many cubic yards of concrete should be ordered?
Answer: 32.6 cubic yards
Volume = 40 x 60 x (4 / 12) = 800 cubic feet; 800 / 27 = 29.63 cubic yards. Adding 10 percent waste: 29.63 x 1.10 = 32.6 cubic yards. 29.6 forgets the waste; 35.6 adds 20 percent instead of 10; 88.9 forgets to convert 4 inches to feet (2,400 / 27).
Reference: Contractor estimating arithmetic, Estimating: concrete volume (cubic feet divided by 27 for cubic yards)
What single-project value may the holder of a limited general contractor license undertake, excluding cost of land and ancillary land improvements?
Answer: Up to $750,000
G.S. 87-10(a1) lets a limited license holder act as general contractor on any single project valued up to $750,000, an intermediate license holder up to $1,500,000, and an unlimited license holder without restriction as to value.
Reference: N.C. General Statutes Chapter 87, Article 1, G.S. 87-10(a1)
What is the distance from the front of the pitcher's rubber to the rear point of home plate on a regulation adult baseball field?
Answer: 60 feet 6 inches
The pitcher's rubber is 60 feet 6 inches from home plate on a regulation adult baseball field. Shorter pitching distances such as 46 feet are used in youth leagues.
Reference: Official Baseball Rules (MLB), 2025, Rule 2.04 The Pitcher's Plate (60 feet, 6 inches to home base)
Sources
- PSI: NC Licensing Board for General Contractors Candidate Information Bulletin (updated 11/9/2026) (opens in a new tab)
- NC Licensing Board for General Contractors (NCLBGC) (opens in a new tab)
- NC Office of State Fire Marshal: code book sales (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.