Requirements at a glance
| Agency | New Mexico Regulation and Licensing Department, Construction Industries Division (CID); exams by PSI |
|---|---|
| Exam | 70 questions, 185 minutes, 75% to pass, open book, plus a practical exam |
| Books allowed | 2021 UPC and UMC, NMAC 14.8.2 and 14.9.2, and IPT's Pipe Trades Handbook (2016) |
| Fees | Exam fees are paid to PSI (see the exam details above); license fees are separate. Check CID for current license fees. |
| Timing | Test within 6 months of becoming eligible. The exam fee and a passing score are each valid for 1 year. |
Plumbers applying to Construction Industries Division for a journeyman plumber certificate. You also take a hands-on practical exam.
Official links
How to get licensed, step by step
Apply to CID through PSI
Candidates must be pre-approved before they can schedule. Submit your application and proof of qualifications through PSI's New Mexico construction page, or call PSI's approvals line at 877-663-9267.
PSI: apply and schedule New Mexico exams (opens in a new tab)New Mexico Construction Industries Division (CID) (opens in a new tab)
Get your references
Buy the exact code editions in PSI's bulletin. Books must be bound; highlighting, underlining and permanent tabs are allowed, but no loose notes or Post-its.
PSI Journeyman Candidate Information Bulletin (opens in a new tab)New Mexico Administrative Code (NMAC) titles (opens in a new tab)
Schedule and pay PSI
After approval, contact PSI to schedule a seat and pay. Test sites include Albuquerque, Farmington, Las Cruces, Roswell and Santa Fe.
PSI: apply and schedule New Mexico exams (opens in a new tab)
Pass and finish your license
You need 75%. You may not take the same exam more than twice in 30 days. Contractors also need the Business and Law exam; journeyman candidates take a hands-on practical exam too.
New Mexico Construction Industries Division (CID) (opens in a new tab)PSI Journeyman Candidate Information Bulletin (opens in a new tab)
How to prepare
- Drainage, waste and vents is 21 of 70 questions; general knowledge and regulations is 10.
- Know trap arms, venting, fixture units and water supply sizing, and where each sits in the UPC.
- The hands-on practical covers copper and PEX assembly and a tub assembly; our questions cover the written exam only.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2021 UPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
Uniform Plumbing Code (UPC), 2021 (IAPMO)Essential
The main plumbing code for the exam, with the New Mexico plumbing code (NMAC 14.8.2).
Uniform Mechanical Code (UMC), 2021 (IAPMO)
Gas piping, combustion air and venting for the gas fitter exams; the main code for MM-3 HVAC and pipe fitter; the plumbing exams list it too.
IPT's Pipe Trades Handbook, Robert A. Lee, 2016
Listed as an allowed reference for the plumbing, gas fitter, HVAC and pipe fitter exams.
Official reference list (as published by the testing agency)
- Uniform Plumbing Code (UPC), 2021 (IAPMO)
- New Mexico Plumbing Code (NMAC 14.8.2)
- Uniform Mechanical Code (UMC), 2021 (IAPMO)
- New Mexico Mechanical Code (NMAC 14.9.2)
- IPT's Pipe Trades Handbook, Robert A. Lee, 2016
What's on the exam
Official content outline from PSI, (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Drainage, Waste, and Vents | 21 | |
| Water Supply Systems | 6 | |
| Backflow Prevention | 6 | |
| Storm Drainage Systems | 6 | |
| Plumbing Fixtures, including Water Heaters and Accessibility | 8 | |
| General Knowledge and General Regulations | 10 | |
| Interceptors and Traps | 4 | |
| Isometric Analysis | 5 | |
| Septic and Sewer | 4 |
Exam day details
- Administered by PSI, for the New Mexico Regulation and Licensing Department, Construction Industries Division (CID).
- Fee: $68.88 per exam, paid to PSI. License and application fees are separate.
- 70 questions in 185 minutes; 75% to pass (53 points).
- Open book. Bring bound references; you may highlight, underline and index them with permanent tabs only. No loose papers, notes or Post-it tabs, and no writing in the books.
- The journeyman license also needs a hands-on practical exam (100 points, 120 minutes, 75% to pass, $68.88). Our questions cover the written portion only.
- Get CID pre-approval through PSI first (PSI approvals line 877-663-9267). Once you are eligible you must test within 6 months, or reapply with the Division. Your exam fee is valid for 1 year and a passing score is valid for 1 year.
- You may not take the same exam more than twice in a 30-day period; after two fails you must wait 30 days from your first attempt.
- Drainage, waste and vents is 21 of the 70 questions.
Frequently asked questions
What's on the New Mexico journeyman plumber exam?
PSI's outline, 70 questions: Drainage, Waste, and Vents 21; Water Supply Systems 6; Backflow Prevention 6; Storm Drainage Systems 6; Plumbing Fixtures, including Water Heaters and Accessibility 8; General Knowledge and General Regulations 10; Interceptors and Traps 4; Isometric Analysis 5; Septic and Sewer 4.
Which code editions does the New Mexico exam use?
PSI's bulletin pins the editions: for electrical, the 2020 NEC plus the New Mexico Electrical Code (NMAC 14.10.4); for plumbing and gas, the 2021 UPC and UMC plus the New Mexico plumbing and mechanical codes (NMAC 14.8.2 and 14.9.2); for building, the 2021 IRC or IBC plus NMAC 14.7.3 or 14.7.2. Code questions use only the listed edition.
Who gives the New Mexico contractor and journeyman exams?
PSI, for the Construction Industries Division (CID) of the Regulation and Licensing Department. CID pre-approves your application, then you schedule with PSI at a New Mexico test center (Albuquerque, Farmington, Las Cruces, Roswell or Santa Fe) or an approved center elsewhere.
Free questions with answers
Show all 10 free questions and answers
A 6-inch building sewer is laid at the reduced slope of 1/8 inch per foot with the approval of the authority having jurisdiction. Using Table 703.2 and its horizontal-slope note, what is the maximum number of fixture units it may carry?
Answer: 576 fixture units
Table 703.2 lists 720 fixture units for a horizontal 6-inch drain at 1/4 inch per foot. The footnote says to multiply horizontal fixture units by 0.8 for a 1/8 inch per foot slope: 720 x 0.8 = 576. The 720 answer ignores the reduced slope, and 900 divides by 0.8 instead of multiplying.
Reference: 2021 Uniform Plumbing Code, Table 703.2, note 5
A newly installed copper hot and cold water system is to be tested with air. What minimum air pressure does the UPC require, and how long must the system hold it without leakage?
Answer: 50 psi minimum, held for at least 15 minutes
UPC 609.4 permits testing with water or air. Water test pressure must be at least the working pressure; air pressure must be at least 50 psi. In either case the system must show no leakage for not less than 15 minutes. Plastic pipe may not be air tested except PEX, PP or PE-RT where the manufacturer permits.
Reference: 2021 Uniform Plumbing Code, 609.4
A faucet with an effective opening of 3/4 inch discharges into a basin and is not affected by sidewalls. What is the minimum air gap under Table 603.3.1?
Answer: 1 1/2 inches
Table 603.3.1 gives a minimum air gap of 1 inch for effective openings up to 1/2 inch, 1 1/2 inches for up to 3/4 inch, and 2 inches for up to 1 inch when not affected by sidewalls. The 2 1/4 inch value is the 3/4 inch opening where affected by sidewalls.
Reference: 2021 Uniform Plumbing Code, Table 603.3.1
Using Table 1103.1 and its note for rainfall rates not listed, what is the maximum horizontal projected roof area a 3-inch vertical leader can serve at a rainfall rate of 2.5 inches per hour?
Answer: 3,520 square feet
Table 1103.1 note 2 says to divide the allowable area in the 1 in/h column by the desired rainfall rate. For a 3-inch leader the 1 in/h area is 8,800 sq ft, and 8,800 / 2.5 = 3,520 sq ft. Multiplying, instead of dividing, gives an unrealistically large area.
Reference: 2021 Uniform Plumbing Code, Table 1103.1, note 2
Three wall-hung urinals are being roughed in side by side in a public restroom. What is the minimum center-to-center spacing?
Answer: 24 inches
UPC 402.5 requires urinals to be at least 24 inches center to center and at least 12 inches from their center to a side wall or partition. The 30-inch figure is for water closets.
Reference: 2021 Uniform Plumbing Code, 402.5
A restaurant kitchen has a two-compartment sink with each compartment measuring 24 by 24 by 12 inches deep, filled to the standard fill factor of 0.75. What total load in gallons does the sink send to a grease interceptor? Use 231 cubic inches per gallon.
Answer: 44.9 gallons
Per the UPC 1014.2.1 example, load = length x width x depth / 231 x 0.75 fill factor. One compartment: 24 x 24 x 12 = 6,912 cu in; 6,912 / 231 = 29.92 gal; x 0.75 = 22.44 gal. Two compartments: 44.9 gal. Forgetting the fill factor gives 59.8 gal, and 29.9 is one compartment unfilled.
Reference: 2021 Uniform Plumbing Code, Section 1014.2.1, Example 1014.2.1
A property has public sewer available at its lot line, 60 feet from the house. The owner asks the AHJ for a permit to build a new septic tank and disposal field. What does the UPC say?
Answer: No permit is issued for a private system where a public sewer connection is available
UPC 713.5 states no permit shall be issued for installation, alteration or repair of a private sewage disposal system on a lot for which a connection to a public sewer is available. Public sewer is available when within 200 feet (713.4).
Reference: 2021 Uniform Plumbing Code, 713.5
Under the New Mexico Plumbing Code, who is the authority having jurisdiction for adopting and enforcing the state plumbing code?
Answer: CID and the mechanical-plumbing trade bureau chief
NMAC 14.8.2.10 deletes the UPC definition of authority having jurisdiction (203.0) and substitutes: the AHJ is the Construction Industries Division (CID) and the mechanical-plumbing trade bureau chief, for adoption, enactment, interpretation and enforcement of the state-adopted plumbing code as the minimum requirement in the state.
Reference: New Mexico Plumbing Code, NMAC 14.8.2, 14.8.2.10 (amending UPC 203.0)
Which drainage fitting is prohibited by the UPC?
Answer: A running thread
UPC 310.1 prohibits double hub fittings, single or double tee branches, single or double tapped tee branches, side-inlet quarter bends, running threads, bands and saddles as drainage fittings, with a limited exception for a double hub sanitary tapped tee on a vertical line. Section 310.2 bars drilling and tapping drainage or vent pipe.
Reference: 2021 Uniform Plumbing Code, 310.1
A 4-inch horizontal building drain is approved by the authority having jurisdiction to run at 1/8 inch per foot. How much total fall does it have over 60 feet, and how does that compare with 1/4 inch per foot?
Answer: 7.5 inches, half of the 15 inches at 1/4 inch per foot
Fall at 1/8 inch per foot over 60 feet = 60 x 1/8 = 7.5 inches. At 1/4 inch per foot it would be 60 x 1/4 = 15 inches. UPC 708.1 allows 1/8 inch per foot only for pipe 4 inches or larger where 1/4 inch is impractical and the AHJ approves.
Reference: 2021 Uniform Plumbing Code, 708.1
Sources
- PSI: New Mexico Journeyman Candidate Information Bulletin (updated 4/13/2023) (opens in a new tab)
- New Mexico Construction Industries Division: Exams (opens in a new tab)
- PSI: New Mexico Construction Industries exams (opens in a new tab)
Questions last verified November 2, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.