New Mexico Journeyman Natural Gas Fitter Exam: Practice Test & Licensing Guide

New Mexico's journeyman natural gas fitter written exam (JG): 70 questions on gas piping, sizing, appliances, combustion air and venting. Open book, 75% to pass.

Questions
70
Time limit
3.3333333333333335 hours
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Gas Sizing

A natural gas system (SG 0.60) is supplied at less than 2 psi and is designed for a 0.5 in. w.c. pressure drop. The longest run from the meter to the farthest outlet is 40 feet and the total load is 150 cubic feet per hour. What is the smallest Schedule 40 steel pipe size that Table 1215.2(1) allows for this section?

Requirements at a glance

AgencyNew Mexico Regulation and Licensing Department, Construction Industries Division (CID); exams by PSI
Exam70 questions, 200 minutes, 75% to pass, open book, plus a practical exam
Books allowed2021 UPC and UMC, NMAC 14.8.2 and 14.9.2, and IPT's Pipe Trades Handbook (2016); Modern Refrigeration and Air Conditioning (19th or 20th ed.)
FeesExam fees are paid to PSI (see the exam details above); license fees are separate. Check CID for current license fees.
TimingTest within 6 months of becoming eligible. The exam fee and a passing score are each valid for 1 year.

Gas fitters applying to Construction Industries Division for a journeyman natural gas fitter certificate. You also take a hands-on practical exam.

How to get licensed, step by step

  1. Apply to CID through PSI

    Candidates must be pre-approved before they can schedule. Submit your application and proof of qualifications through PSI's New Mexico construction page, or call PSI's approvals line at 877-663-9267.

    PSI: apply and schedule New Mexico exams (opens in a new tab)New Mexico Construction Industries Division (CID) (opens in a new tab)

  2. Get your references

    Buy the exact code editions in PSI's bulletin. Books must be bound; highlighting, underlining and permanent tabs are allowed, but no loose notes or Post-its.

    PSI Journeyman Candidate Information Bulletin (opens in a new tab)New Mexico Administrative Code (NMAC) titles (opens in a new tab)

  3. Schedule and pay PSI

    After approval, contact PSI to schedule a seat and pay. Test sites include Albuquerque, Farmington, Las Cruces, Roswell and Santa Fe.

    PSI: apply and schedule New Mexico exams (opens in a new tab)

  4. Pass and finish your license

    You need 75%. You may not take the same exam more than twice in 30 days. Contractors also need the Business and Law exam; journeyman candidates take a hands-on practical exam too.

    New Mexico Construction Industries Division (CID) (opens in a new tab)PSI Journeyman Candidate Information Bulletin (opens in a new tab)

How to prepare

  • Piping (17), general knowledge and principles (12) and gas sizing (12) are 41 of 70 questions: practice the sizing tables.
  • Combustion air and chimneys, flues and vents are 7 questions each; know the UMC rules.
  • The practical includes altitude derating, so know how elevation affects input ratings.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2021 UPC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

  • Uniform Mechanical Code (UMC), 2021 (IAPMO)

    Gas piping, combustion air and venting for the gas fitter exams; the main code for MM-3 HVAC and pipe fitter; the plumbing exams list it too.

    IAPMO (opens in a new tab)

  • Uniform Plumbing Code (UPC), 2021 (IAPMO)Essential

    The main plumbing code for the exam, with the New Mexico plumbing code (NMAC 14.8.2).

    IAPMO (opens in a new tab)

  • IPT's Pipe Trades Handbook, Robert A. Lee, 2016

    Listed as an allowed reference for the plumbing, gas fitter, HVAC and pipe fitter exams.

Official reference list (as published by the testing agency)
  • Uniform Plumbing Code (UPC), 2021 (IAPMO)
  • New Mexico Plumbing Code (NMAC 14.8.2)
  • Uniform Mechanical Code (UMC), 2021 (IAPMO)
  • New Mexico Mechanical Code (NMAC 14.9.2)
  • IPT's Pipe Trades Handbook, Robert A. Lee, 2016
  • Modern Refrigeration and Air Conditioning, 19th or 20th Edition

What's on the exam

Official content outline from PSI, (number of questions per topic):

TopicQuestions
General Knowledge and Principles12
Piping17
Gas Sizing12
Controls and Testing5
Appliances7
Combustion Air7
Chimneys, Flues, and Vents7
Heating Systems3

Exam day details

  • Administered by PSI, for the New Mexico Regulation and Licensing Department, Construction Industries Division (CID).
  • Fee: $68.88 per exam, paid to PSI. License and application fees are separate.
  • 70 questions in 200 minutes; 75% to pass (53 points).
  • Open book. Bring bound references; you may highlight, underline and index them with permanent tabs only. No loose papers, notes or Post-it tabs, and no writing in the books.
  • The journeyman license also needs a hands-on practical exam (100 points, 120 minutes, 75% to pass, $68.88). Our questions cover the written portion only.
  • Get CID pre-approval through PSI first (PSI approvals line 877-663-9267). Once you are eligible you must test within 6 months, or reapply with the Division. Your exam fee is valid for 1 year and a passing score is valid for 1 year.
  • You may not take the same exam more than twice in a 30-day period; after two fails you must wait 30 days from your first attempt.
  • Piping (17), general knowledge and principles (12) and gas sizing (12) are more than half the exam.

Frequently asked questions

What's on the New Mexico journeyman gas fitter exam?

PSI's outline, 70 questions: General Knowledge and Principles 12; Piping 17; Gas Sizing 12; Controls and Testing 5; Appliances 7; Combustion Air 7; Chimneys, Flues, and Vents 7; Heating Systems 3.

Which code editions does the New Mexico exam use?

PSI's bulletin pins the editions: for electrical, the 2020 NEC plus the New Mexico Electrical Code (NMAC 14.10.4); for plumbing and gas, the 2021 UPC and UMC plus the New Mexico plumbing and mechanical codes (NMAC 14.8.2 and 14.9.2); for building, the 2021 IRC or IBC plus NMAC 14.7.3 or 14.7.2. Code questions use only the listed edition.

Who gives the New Mexico contractor and journeyman exams?

PSI, for the Construction Industries Division (CID) of the Regulation and Licensing Department. CID pre-approves your application, then you schedule with PSI at a New Mexico test center (Albuquerque, Farmington, Las Cruces, Roswell or Santa Fe) or an approved center elsewhere.

Free questions with answers

Show all 10 free questions and answers
  1. A natural gas system (SG 0.60) is supplied at less than 2 psi and is designed for a 0.5 in. w.c. pressure drop. The longest run from the meter to the farthest outlet is 40 feet and the total load is 150 cubic feet per hour. What is the smallest Schedule 40 steel pipe size that Table 1215.2(1) allows for this section?

    Answer: 3/4 inch

    Use the 40 ft row of Table 1215.2(1). The 1/2 inch column carries only 81 cfh there, which is too small. The 3/4 inch column carries 170 cfh, which covers 150 cfh. A 1 inch pipe would work but is larger than needed.

    Reference: 2021 Uniform Plumbing Code, Table 1215.2(1)

  2. A furnace rated 120,000 Btu/h and a water heater rated 40,000 Btu/h are supplied by one branch. The gas supplier states a heating value of 1,100 Btu per cubic foot. The longest length is 30 feet, and the system is natural gas at less than 2 psi with a 0.5 in. w.c. drop. What pipe size does Table 1215.2(1) require for the section serving both appliances?

    Answer: 3/4 inch

    Load = (120,000 + 40,000) / 1,100 = 160,000 / 1,100 = 145.5 cfh (Section 1214.2 divides input by the heating value). In the 30 ft row of Table 1215.2(1), 1/2 inch carries 95 cfh (too small) and 3/4 inch carries 199 cfh, which is the smallest size that covers 145.5 cfh.

    Reference: 2021 Uniform Plumbing Code, Table 1215.2(1); Section 1214.2

  3. A New Mexico gas fitter proposes to run 3/4 inch copper pipe for a natural gas line in a new building. What does the New Mexico plumbing code say?

    Answer: Copper and brass pipe may not be used; NMAC 14.8.2 replaces UPC Section 1208.6.3.2 with this prohibition

    NMAC 14.8.2.22(A) deletes UPC Section 1208.6.3.2 and substitutes: copper and brass pipe shall not be used (the UMC version, 14.9.2.21, says copper and copper alloy pipe shall not be used). The 0.3 grain hydrogen sulfide limit is the unamended UPC rule, and the state amendment overrides it. Because NM changes the UPC here, the exam answer follows NMAC.

    Reference: NMAC 14.8.2 (New Mexico Plumbing Code), amending 2021 UPC, 14.8.2.22 NMAC (A), amending UPC Section 1208.6.3.2

  4. A trench for buried steel gas pipe crosses a driveway where vehicle loads are likely to damage the pipe. What cover is required under Section 1210.1.1?

    Answer: 18 inches

    Section 1210.1.1 sets a 12 inch minimum, increased to 18 inches (457 mm) if external damage to the pipe from external forces is likely to result. If the minimum cover cannot be provided, the pipe must be installed in conduit or bridged.

    Reference: 2021 Uniform Plumbing Code, Section 1210.1.1

  5. Zinc coating (galvanizing) on steel gas pipe installed underground is considered to be what under the UPC?

    Answer: Not adequate protection against corrosion on its own

    Section 1210.1.3.1 says zinc coating (galvanizing) shall not be deemed adequate protection for underground gas piping. Section 1210.1.3.2 requires one or more of the following: corrosion-resistant material suitable for the environment, a factory-applied electrically insulating coating, or a cathodic protection system.

    Reference: 2021 Uniform Plumbing Code, Section 1210.1.3.1

  6. Appliances totaling 120,000 Btu/h are in a closet that gets all of its combustion air through two permanent openings directly to the outdoors. What is the minimum free area of EACH opening?

    Answer: 30 square inches

    Section 701.6.1(1): where the openings communicate directly with the outdoors or through vertical ducts, each opening needs a minimum free area of 1 square inch per 4,000 Btu/h. 120,000 / 4,000 = 30 square inches per opening, one within 12 inches of the top and one within 12 inches of the bottom of the enclosure. The 60 square inch figure is the horizontal duct rate (1 per 2,000 Btu/h).

    Reference: 2021 Uniform Mechanical Code, Section 701.6.1

  7. A Type B gas vent serves a draft hood appliance. How far above the highest connected draft hood or flue collar must the vent terminate?

    Answer: At least 5 feet in vertical height

    Section 802.6.1(2) requires a Type B or Type L gas vent to terminate at least 5 feet in vertical height above the highest connected appliance draft hood or flue collar. The 2 foot figure applies to clearance above the roof and nearby building portions, and 3 feet applies above a forced air inlet within 10 feet.

    Reference: 2021 Uniform Mechanical Code, Section 802.6.1

  8. New Mexico amends UMC Section 907.2 for unlisted wall furnaces. What clearance to combustible material does NMAC 14.9.2.17 require?

    Answer: Not less than 18 inches

    NMAC 14.9.2.17 keeps UMC Section 907.2 and adds that unlisted wall furnaces shall be installed with clearances to combustible material of not less than 18 inches. Unlisted wall furnaces also may not be installed in or attached to combustible material (Section 907.1.1).

    Reference: NMAC 14.9.2 (New Mexico Mechanical Code), amending 2021 UMC, 14.9.2.17 NMAC, amending UMC Section 907.2

  9. New Mexico amends the hydronic piping test in UMC Chapter 12. What test does NMAC 14.9.2.20 require for system piping?

    Answer: A hydrostatic or air test of not less than 1.5 times the operating pressure

    NMAC 14.9.2.20 keeps UMC Section 1205.2 but replaces the first sentence: system piping shall be tested with a hydrostatic pressure or an air test of not less than 1.5 times operating pressure.

    Reference: NMAC 14.9.2 (New Mexico Mechanical Code), amending 2021 UMC, 14.9.2.20 NMAC, amending UMC Section 1205.2

  10. A system carries gas at 2 psi, above 14 in. w.c. What is the minimum test pressure and test duration under the UPC?

    Answer: 60 psi, for at least 30 minutes

    Section 1213.3: for welded piping, and for piping carrying gas at pressures in excess of 14 inches water column, the test pressure shall be not less than 60 psi and continued for a time satisfactory to the AHJ, but not less than 30 minutes. CSST above 14 in. w.c. is tested at not less than 30 psi for 30 minutes.

    Reference: 2021 Uniform Plumbing Code, Section 1213.3

Sources

Questions last verified November 2, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.