Requirements at a glance
| Agency | Fire Alarm, Burglar Alarm and Locksmith Advisory Committee (Division of Consumer Affairs); exams by PSI |
|---|---|
| Eligibility | See N.J.A.C. 13:31A and the Committee's application |
| Exams | Fire Alarm, plus Business and Law |
| Fees | $84 to PSI (Business and Law is $47), plus Board application and license fees |
Candidates for a New Jersey fire alarm business license from the Fire Alarm, Burglar Alarm and Locksmith Advisory Committee.
Official links
How to get licensed, step by step
Apply to the board
Get the Board's approval to test. It sends an Examination Eligibility Notice with instructions for paying and scheduling.
New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
Schedule the fire alarm exam and Business and Law with PSI
Pay and schedule with PSI online or at (855) 340-3713. First-time candidates take all required exams on the same day. Fees are not refundable or transferable and are valid for one year.
Schedule with PSI (NJ fire alarm, burglar alarm and locksmith) (opens in a new tab)
Retake if needed
Retake only the exams you failed, after the waiting period your board sets (6 months between attempts for most boards). Check your Eligibility Notice for the exact limits.
Schedule with PSI (NJ fire alarm, burglar alarm and locksmith) (opens in a new tab)
Get licensed
PSI sends your results to the board. Contact the board for the license application, fees and insurance requirements.
New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline, and check the bulletin again before test day. New Jersey adopted newer codes in August 2026, but the exam bulletins still name the 2023 NEC, the 2021 National Standard Plumbing Code and the 2021 IMC and IFGC.
- First-time candidates take all required exams on the same day, so practice the trade exam and Business and Law together.
- You can highlight, underline and index books you bring, but not write in them. The 2023 NEC is provided at the electrical and alarm test centers.
- Application of fire alarm systems is 20 of the 50 questions: know NFPA 72 on notification appliances, detector spacing, testing and supervisory stations.
- Bring your own NFPA 72 (2022), A117.1-2017 and the Barrier Free Subcode; PSI provides only the NEC.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC and NFPA 72. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 EditionEssential
Most of the exam. Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 314, 430 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
NFPA 72: National Fire Alarm and Signaling Code, 2022 EditionEssential
Bring your own copy. Most of the application questions come from it.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 Edition (provided at the test center; you can't use your own copy)
- NFPA 72: National Fire Alarm and Signaling Code, 2022 Edition (bring your own)
- ICC/ANSI A117.1-2017, Accessible and Usable Buildings and Facilities (earlier editions may be used until January 1, 2027)
- New Jersey Administrative Code, Barrier Free Subcode (N.J.A.C. 5:23-7)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 10 | |
| Installation Requirements (Power Supplies, Grounding and Bonding, Raceways and Boxes) | 5 | |
| Wiring Methods and Materials (Signaling Circuits, Conductors and Cables) | 10 | |
| Special Occupancies and Conditions | 5 | |
| Application of Fire Alarm Systems | 20 |
Exam day details
- Administered by PSI Services for the New Jersey Division of Consumer Affairs boards.
- Fee: $84 to PSI. Committee application and license fees are separate.
- 50 questions in 130 minutes; 35 correct (70%) to pass.
- Application of Fire Alarm Systems (20 questions) covers general requirements, installation, audible and visual notification, heat and smoke detection, testing and inspections, and supervisory stations.
- First-time candidates take all three required exams on the same day (Business and Law plus the alarm exams for the license).
- If you fail on the first attempt, retake the failed exam(s) within 24 months of your first test date. Wait 6 months before a third attempt. You must pass within three attempts and take the first attempt within 6 months of your eligibility date; otherwise you retake all three.
- Your board (or committee) must approve your application first and sends an Examination Eligibility Notice. Then you pay and schedule with PSI by phone at (855) 340-3713 or online.
- Exam fees are not refundable or transferable and are valid for one year from payment.
- References may be highlighted, underlined and indexed before the exam but not written in; loose or attached papers are not allowed. A book PSI provides at the test center can't be marked.
Frequently asked questions
What's on the New Jersey fire alarm exam?
50 questions: application of fire alarm systems 20, general electrical knowledge 10, wiring methods and materials 10, installation requirements 5 and special occupancies and conditions 5.
Which books does the New Jersey fire alarm exam use?
The 2023 NEC (provided at the test center), NFPA 72 (2022), ICC A117.1-2017 and the New Jersey Barrier Free Subcode. You bring everything except the NEC.
How many times can I take it?
Three attempts. After a failed second attempt wait 6 months before the third. If you don't pass in three attempts you retake all three exams.
Free questions with answers
Show all 10 free questions and answers
A supervised 24-volt notification appliance circuit has a total circuit resistance of 16 ohms. What current flows in the circuit?
Answer: 1.5 amperes
Ohm's law gives I = E / R = 24 V / 16 ohms = 1.5 A. The 0.67 A answer inverts the formula (R / E = 16 / 24), 384 A multiplies the two values, and 8 A subtracts them, which has no basis in Ohm's law.
Reference: Electrical theory (Ohm's law), I = E / R
Two resistive loads of 30 ohms and 60 ohms are connected in parallel across the same supply. What is their equivalent resistance?
Answer: 20 ohms
For two resistors in parallel, R = (R1 x R2) / (R1 + R2) = (30 x 60) / 90 = 20 ohms. The 90 ohm value is the series answer, 45 ohms is a simple average, and 10 ohms is half of the correct value. A parallel combination is always smaller than the smallest branch, which rules out 45 and 90.
Reference: Electrical theory (parallel circuits), Parallel resistance, R = R1 x R2 / (R1 + R2)
A technician plans to feed a new fire alarm control unit from an existing 20-ampere circuit that also serves lobby receptacles and is protected by a GFCI breaker. Which Article 760 rule does this break?
Answer: The circuit must serve no other loads and have no GFCI or AFCI
Section 760.121(B) requires the branch circuit supplying fire alarm equipment to supply no other loads and not be supplied through ground-fault or arc-fault circuit interrupters (the same limits appear in 760.41(B) for NPLFA). A nuisance trip would silently remove power from the system.
Reference: NEC 2023 (NFPA 70), 760.121(B)(1) and (B)(2)
Under the 2023 NEC, which device must be installed on the supply side of a fire alarm control panel?
Answer: A listed surge-protective device (SPD)
New Section 760.33 requires a listed surge-protective device on the supply side of a fire alarm control panel, installed in accordance with Part II of Article 242. GFCI and AFCI protection are specifically not allowed on the fire alarm branch circuit by 760.121(B).
Reference: NEC 2023 (NFPA 70), 760.33
An installer wants to use 16 AWG conductors for a non-power-limited fire alarm circuit. Under Section 760.49(A), under what condition is this permitted?
Answer: They are in a raceway, an approved enclosure or a listed cable
Section 760.49(A) lets 16 AWG and 18 AWG NPLFA conductors be used if they supply loads within the ampacities in Table 402.5 and are installed in a raceway, an approved enclosure or a listed cable. Running them exposed on a wall, even when well secured, does not meet that condition, and twisting them with a grounding conductor or keeping them inside the panel is not what the rule asks for.
Reference: NEC 2023 (NFPA 70), 760.49(A)
A single-phase transformer with a 2-wire secondary, 240 V primary and 120 V secondary, supplies 14 AWG NPLFA conductors with an ampacity of 15 A. Under Exception No. 2 to 760.45, what is the maximum primary overcurrent protection that may be used to protect the secondary conductors, if it also complies with 450.3?
Answer: 7.5 amperes
The primary protection may not exceed the secondary conductor ampacity multiplied by the secondary-to-primary voltage ratio: 15 A x (120 / 240) = 15 x 0.5 = 7.5 A. Using 15 A ignores the ratio, 30 A uses the inverse ratio, and 3.75 A applies the ratio twice.
Reference: NEC 2023 (NFPA 70), 760.45, Exception No. 2
A fire alarm device is to be mounted in an area classified as hazardous (classified). Under Section 760.10, when are fire alarm cables and equipment allowed there?
Answer: Where specifically permitted by other articles in the Code
Section 760.10 permits fire alarm cables and equipment in hazardous (classified) locations where specifically permitted by other articles, such as the Chapter 5 hazardous location articles. Being power limited does not by itself make a device suitable for the location.
Reference: NEC 2023 (NFPA 70), 760.10
Spot-type heat detectors with a listed spacing of 40 ft are installed on a smooth ceiling. Using the 0.7 rule, what is the greatest distance allowed from any point on the ceiling to the nearest heat detector?
Answer: 28 feet
On a smooth ceiling every point must be within 0.7 times the listed spacing of a detector: 0.7 x 40 ft = 28 ft. Twenty feet is half the spacing (the wall rule for heat detectors), 40 ft is the listed spacing itself, and 56 ft is 1.4 times the spacing.
Reference: NFPA 72, National Fire Alarm and Signaling Code, 2022, 17.6.3.1.1 (Smooth Ceiling, Spacing of heat detectors)
A ceiling-mounted smoke detector should be kept at least how far from an air supply diffuser, according to the annex guidance?
Answer: 3 ft (0.9 m)
Annex guidance says smoke detectors should not be placed in a direct airflow or closer than 36 in. (910 mm) to a supply diffuser or return opening, because the air stream can dilute or divert smoke away from the detector. Larger supply sources can require more distance.
Reference: NFPA 72, National Fire Alarm and Signaling Code, 2022, Chapter 17, Initiating Devices (smoke detector location, Annex A)
Which statement best compares photoelectric and ionization smoke detection?
Answer: Photoelectric is generally faster on smoldering fires
Photoelectric detectors sense light scattered by the larger particles of a smoldering fire, while ionization detectors respond better to the small particles of fast flaming fires. Neither type measures heat or carbon monoxide. Photoelectric detectors are often chosen near kitchens and bedrooms.
Reference: NFPA 72, National Fire Alarm and Signaling Code, 2022, Chapter 17, Initiating Devices (smoke detection principles)
Sources
- PSI: New Jersey Fire Alarm, Burglar Alarm and Locksmith exam registration and bulletin (updated 7/30/2026) (opens in a new tab)
- New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.