Requirements at a glance
| Agency | Fire Alarm, Burglar Alarm and Locksmith Advisory Committee (Division of Consumer Affairs); exams by PSI |
|---|---|
| Eligibility | See N.J.A.C. 13:31A and the Committee's application |
| Exams | Electronic Security Systems, plus Business and Law |
| Fees | $49 to PSI (Business and Law is $47), plus Board application and license fees |
Fire alarm, burglar alarm and locksmith license candidates whom the Committee requires to pass the Electronic Security Systems exam. The outline is the same for each track.
Official links
How to get licensed, step by step
Apply to the board
Get the Board's approval to test. It sends an Examination Eligibility Notice with instructions for paying and scheduling.
New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
Schedule the electronic security systems exam and Business and Law with PSI
Pay and schedule with PSI online or at (855) 340-3713. First-time candidates take all required exams on the same day. Fees are not refundable or transferable and are valid for one year.
Schedule with PSI (NJ fire alarm, burglar alarm and locksmith) (opens in a new tab)
Retake if needed
Retake only the exams you failed, after the waiting period your board sets (6 months between attempts for most boards). Check your Eligibility Notice for the exact limits.
Schedule with PSI (NJ fire alarm, burglar alarm and locksmith) (opens in a new tab)
Get licensed
PSI sends your results to the board. Contact the board for the license application, fees and insurance requirements.
New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline, and check the bulletin again before test day. New Jersey adopted newer codes in August 2026, but the exam bulletins still name the 2023 NEC, the 2021 National Standard Plumbing Code and the 2021 IMC and IFGC.
- First-time candidates take all required exams on the same day, so practice the trade exam and Business and Law together.
- You can highlight, underline and index books you bring, but not write in them. The 2023 NEC is provided at the electrical and alarm test centers.
- General electrical knowledge (17), CCTV (13) and access control (12) make up most of the exam; intercom systems are 8.
- Bring the NTC Yellow Book and Blue Book (2025 editions) and CCTV from Light to Pixels; PSI provides only the NEC.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC and the NTC Yellow Book and the NTC Blue Book. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 EditionEssential
Most of the exam. Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 314, 430 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
NTC Yellow Book: Video Security Systems Handbook (2025)Essential
Bring your own copy. The 2022 edition is no longer allowed.
NTC Blue Book: Security System Design and Installation (2025 print) or Low Voltage Systems Handbook (2025)Essential
Bring your own copy. The 2020 edition is no longer allowed.
CCTV from Light to Pixels, 3rd Edition (2014)
Bring your own copy.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 Edition (provided at the test center; you can't use your own copy)
- NTC Yellow Book: Video Security Systems Handbook (2025 edition; the 2022 edition is no longer allowed since 10/1/2025) (bring your own)
- NTC Blue Book: Security System Design and Installation, 2025 print (or NTC Blue Book: Low Voltage Systems Handbook, 2025). The 2020 edition is no longer allowed since 10/1/2025 (bring your own)
- CCTV from Light to Pixels, 3rd Edition, 2014 (bring your own)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge (Ohm's Law, General Requirements, Grounding, Low Voltage Circuits, Raceways, Conductors and Cables, Optic Fiber Cable) | 17 | |
| CCTV Systems | 13 | |
| Access Control Systems | 12 | |
| Intercom Systems | 8 |
Exam day details
- Administered by PSI Services for the New Jersey Division of Consumer Affairs boards.
- Fee: $49 to PSI. Committee application and license fees are separate.
- 50 questions in 165 minutes; 35 correct (70%) to pass.
- Electronic security systems include access control, CCTV, intercom and other electronic monitoring devices. PSI lists the exam separately for the fire alarm, burglar alarm and locksmith tracks with the same outline.
- First-time candidates take all three required exams on the same day.
- Committee exams: if you fail on the first attempt, retake the failed exam(s) within 24 months of your first test date, and wait 6 months before a third attempt. You must pass within three attempts and take the first attempt within 6 months of your eligibility date; otherwise you retake all three.
- Your board (or committee) must approve your application first and sends an Examination Eligibility Notice. Then you pay and schedule with PSI by phone at (855) 340-3713 or online.
- Exam fees are not refundable or transferable and are valid for one year from payment.
- References may be highlighted, underlined and indexed before the exam but not written in; loose or attached papers are not allowed. A book PSI provides at the test center can't be marked.
Frequently asked questions
What's on the New Jersey electronic security systems exam?
50 questions: general electrical knowledge 17, CCTV systems 13, access control systems 12 and intercom systems 8.
Which books does it use?
The 2023 NEC (provided at the test center), the NTC Yellow Book (video security) and Blue Book (2025 editions) and CCTV from Light to Pixels, 3rd Edition. You bring everything except the NEC.
Is the outline different for fire alarm, burglar alarm and locksmith candidates?
No. PSI prints the same outline and 165-minute time limit for each track.
Free questions with answers
Show all 10 free questions and answers
Three resistors of 100, 150 and 250 ohms are wired in series across a 12-volt DC source. What current flows in the circuit?
Answer: 24 mA
Series resistances add: 100 + 150 + 250 = 500 ohms. I = 12 V / 500 ohms = 0.024 A = 24 mA. Using only the first two resistors gives 48 mA, using only the 100-ohm resistor gives 120 mA, and 2.4 mA is a decimal-place slip.
Reference: General electrical theory, Series circuits: R total = R1 + R2 + R3; I = E / R
Two loads of 30 ohms and 60 ohms are connected in parallel. What is the equivalent resistance?
Answer: 20 ohms
For two parallel resistors, R = (R1 x R2) / (R1 + R2) = (30 x 60) / 90 = 20 ohms. The average (45) and the sum (90) are series-circuit thinking, and half of the smaller resistor (15) applies only when the two resistors are equal.
Reference: General electrical theory, Parallel circuits: R = (R1 x R2) / (R1 + R2)
A 0.5-A current flows through a 20-ohm resistor. How much power does the resistor dissipate?
Answer: 5 watts
P = I squared x R = 0.5 x 0.5 x 20 = 5 W. Forgetting to square the current gives 10 (that is the 10 volts across the resistor), halving gives 2.5, and squaring the resistance instead of the current gives 200.
Reference: General electrical theory, Power formula: P = I squared x R
For a given image sensor size, how does a camera lens with a shorter focal length compare with one that has a longer focal length?
Answer: It gives a wider field of view, but distant objects appear smaller
Focal length and sensor size set the field of view. A short focal length (for example 2.8 mm) is wide-angle and covers a broad scene, but faces or plates far from the camera are small. A long focal length narrows the view and enlarges distant detail.
Reference: DHS S&T SAVER, Video Security Systems Technology Handbook, 2025, 3.2.1 Types of Lenses; 3.2.2.2 Field of View
A lens has an f-stop setting of f/4. Compared with the same lens set to f/5.6, how much light reaches the sensor?
Answer: About twice as much light
A smaller f-number means a wider aperture and more light. Common stops run 1.4, 2, 2.8, 4, 5.6, 8, 11, 16 and 22, and each step toward the smaller number passes about twice the light, so f/4 passes about twice the light of f/5.6.
Reference: DHS S&T SAVER, Video Security Systems Technology Handbook, 2025, 3.2.2.3 Iris and Aperture
An outdoor camera sees bright sun at noon and near darkness at night. Which type of lens iris is best matched to those changing light levels?
Answer: An auto-iris lens, which adjusts the aperture to the light level automatically
Auto-iris lenses use a solenoid driven by a video or DC signal from the camera to open and close the iris, so they work well outdoors or wherever lighting changes a lot. Fixed and manual apertures suit constant, controlled lighting.
Reference: DHS S&T SAVER, Video Security Systems Technology Handbook, 2025, 3.2.2.3 Iris and Aperture
Door hardware release of an electrically locked egress door is used on a door in the means of egress. Which condition must be met under the International Building Code?
Answer: Operating the door hardware directly interrupts power to the lock and unlocks the door immediately
Section 1010.2.11 requires the door hardware to be operable with one hand and to directly interrupt power to the electric lock so the door unlocks immediately. Loss of power also unlocks the door, panic hardware where required releases the lock, and the locking units must be listed to UL 294.
Reference: 2021 International Building Code, 1010.2.11 Door Hardware Release of Electrically Locked Egress Doors
After the manual unlocking device of a sensor-release lock is operated, how long must the electric lock remain unlocked at a minimum?
Answer: 30 seconds
Section 1010.2.12 says that when the manual unlocking device is operated, power to the electric lock is directly interrupted and the lock must remain unlocked for not less than 30 seconds. The 15-second figure belongs to delayed egress locks.
Reference: 2021 International Building Code, 1010.2.12 Sensor Release of Electrically Locked Egress Doors
Two listed Class 2 power supplies are to be connected in parallel to give an intercom system more output current. What does Section 725.60(B) say about this?
Answer: It is not permitted unless the power sources are listed for such interconnection
Section 725.60(B) says Class 2 or Class 3 power sources may not have their output connections paralleled or otherwise interconnected unless listed for such interconnection. Matching ratings, fuses and enclosures do not change the rule, because combined output could exceed the power limits.
Reference: NFPA 70, National Electrical Code, 2023, 725.60(B)
A single cable that holds both Class 2 intercom conductors and telephone-type communications conductors is to be installed. Under Section 725.139(D)(1), what condition applies?
Answer: It must be a listed communications cable installed under Part V of Article 800
Section 725.139(D)(1) permits Class 2 or Class 3 conductors in the same cable with communications circuit conductors if the cable is a listed communications cable installed in accordance with Part V of Article 800. The cable must be listed as a communications cable.
Reference: NFPA 70, National Electrical Code, 2023, 725.139(D)(1)
Sources
- PSI: New Jersey Fire Alarm, Burglar Alarm and Locksmith exam registration and bulletin (updated 7/30/2026) (opens in a new tab)
- New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.