Requirements at a glance
| Agency | Fire Alarm, Burglar Alarm and Locksmith Advisory Committee (Division of Consumer Affairs); exams by PSI |
|---|---|
| Eligibility | See N.J.A.C. 13:31A and the Committee's application |
| Exams | Burglar Alarm, plus Business and Law |
| Fees | $84 to PSI (Business and Law is $47), plus Board application and license fees |
Candidates for a New Jersey burglar alarm business license from the Fire Alarm, Burglar Alarm and Locksmith Advisory Committee.
Official links
How to get licensed, step by step
Apply to the board
Get the Board's approval to test. It sends an Examination Eligibility Notice with instructions for paying and scheduling.
New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
Schedule the burglar alarm exam and Business and Law with PSI
Pay and schedule with PSI online or at (855) 340-3713. First-time candidates take all required exams on the same day. Fees are not refundable or transferable and are valid for one year.
Schedule with PSI (NJ fire alarm, burglar alarm and locksmith) (opens in a new tab)
Retake if needed
Retake only the exams you failed, after the waiting period your board sets (6 months between attempts for most boards). Check your Eligibility Notice for the exact limits.
Schedule with PSI (NJ fire alarm, burglar alarm and locksmith) (opens in a new tab)
Get licensed
PSI sends your results to the board. Contact the board for the license application, fees and insurance requirements.
New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline, and check the bulletin again before test day. New Jersey adopted newer codes in August 2026, but the exam bulletins still name the 2023 NEC, the 2021 National Standard Plumbing Code and the 2021 IMC and IFGC.
- First-time candidates take all required exams on the same day, so practice the trade exam and Business and Law together.
- You can highlight, underline and index books you bring, but not write in them. The 2023 NEC is provided at the electrical and alarm test centers.
- General electrical knowledge is 20 of the 50 questions: practice Ohm's law, voltage drop and power and resistance calculations.
- Bring an NTC Blue Book (2025), A117.1-2017 and the Barrier Free Subcode; PSI provides only the NEC.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC and the NTC Blue Book. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 EditionEssential
Most of the exam. Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 314, 430 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
NTC Blue Book: Security System Design and Installation (2025 print) or Low Voltage Systems Handbook (2025)Essential
Bring your own copy. The 2020 edition is no longer allowed.
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 Edition (provided at the test center; you can't use your own copy)
- NTC Blue Book: Security System Design and Installation, 2025 print, or NTC Blue Book: Low Voltage Systems Handbook, 2025 (bring your own; the 2020 edition is no longer allowed)
- ICC/ANSI A117.1-2017, Accessible and Usable Buildings and Facilities (earlier editions may be used until January 1, 2027)
- New Jersey Administrative Code, Barrier Free Subcode (N.J.A.C. 5:23-7)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge (Ohm's Law, Voltage Drop, Power Supply and Resistance) | 20 | |
| Installation Requirements (Power Supplies, Grounding and Bonding, Raceways and Boxes) | 5 | |
| Wiring Methods and Materials (Signaling Circuits, Conductors and Cables) | 10 | |
| Application of Burglar Systems (Panels, Controls, Notification Equipment, Intrusion Detection) | 15 |
Exam day details
- Administered by PSI Services for the New Jersey Division of Consumer Affairs boards.
- Fee: $84 to PSI. Committee application and license fees are separate.
- 50 questions in 165 minutes; 35 correct (70%) to pass.
- General Electrical Knowledge (20 questions) includes Ohm's law, voltage drop and power and resistance calculations.
- First-time candidates take all three required exams on the same day (Business and Law plus the alarm exams for the license).
- Committee exams: if you fail on the first attempt, retake the failed exam(s) within 24 months of your first test date, and wait 6 months before a third attempt. You must pass within three attempts and take the first attempt within 6 months of your eligibility date; otherwise you retake all three.
- Your board (or committee) must approve your application first and sends an Examination Eligibility Notice. Then you pay and schedule with PSI by phone at (855) 340-3713 or online.
- Exam fees are not refundable or transferable and are valid for one year from payment.
- References may be highlighted, underlined and indexed before the exam but not written in; loose or attached papers are not allowed. A book PSI provides at the test center can't be marked.
Frequently asked questions
What's on the New Jersey burglar alarm exam?
50 questions: general electrical knowledge 20, application of burglar systems 15, wiring methods and materials 10 and installation requirements 5.
Which books does it use?
The 2023 NEC (provided at the test center), an NTC Blue Book (2025), ICC A117.1-2017 and the New Jersey Barrier Free Subcode. You bring everything except the NEC.
Do I need to calculate?
Yes. The general electrical knowledge section includes Ohm's law, voltage drop and power and resistance calculations.
Free questions with answers
Show all 10 free questions and answers
A zone loop is powered with 12 volts. The circuit has a 2,400-ohm end-of-line resistor in series with 100 ohms of loop wiring and contact resistance. What current flows in the loop?
Answer: 4.8 mA
Series resistance = 2400 + 100 = 2500 ohms. I = 12 / 2500 = 0.0048 A = 4.8 mA. Using only the EOL resistor gives 5 mA, using only the wire gives 120 mA, and misplacing the decimal point gives 48 mA.
Reference: General electrical theory, Ohm's law in a series circuit: I = E / R total
A pair of long run conductors has a total resistance of 2.4 ohms and carries 1.5 A to a sounder. How much power is lost as heat in the wire?
Answer: 5.4 W
P = I squared x R = 1.5 x 1.5 x 2.4 = 5.4 W. Multiplying I by R gives volts (3.6), not watts, and the squared term is what makes the loss rise quickly with current.
Reference: General electrical theory, Power formula: P = I squared x R
A 24-volt indicating appliance has a resistance of 96 ohms. How much power does it dissipate at rated voltage?
Answer: 6 W
P = E squared / R = 24 x 24 / 96 = 576 / 96 = 6 W. Dividing E by R gives only the current (0.25 A), not watts; 96 W just restates the resistance; and 12 W is double the correct value.
Reference: General electrical theory, Power formula: P = E squared / R
A device box holds two 14/2 cables with ground. All four insulated conductors terminate on one receptacle yoke, and the two bare grounds are spliced together in the box. The box has no internal clamps. Using 2.00 cu in. per 14 AWG allowance, what is the minimum box volume required?
Answer: 14 cu in.
Count each insulated conductor that terminates in the box: 4 allowances. Add one allowance for all the equipment grounding conductors (up to four) and a double allowance for the yoke: 4 + 1 + 2 = 7 allowances. 7 x 2.00 = 14.0 cu in. Leaving out the grounds gives 12.0, leaving out the device gives 10.0, and counting both grounds separately gives 16.0.
Reference: NFPA 70, National Electrical Code, 2023, 314.16(B)(1), (B)(4) and (B)(5); Table 314.16(B)(1)
Where wires are spliced or terminated at an outlet or junction box, what is the minimum length of free conductor required, measured from where it leaves the raceway or cable sheath?
Answer: 6 inches
Section 300.14 requires at least 6 in. of free conductor at each outlet, junction and switch point, measured from where it emerges from its raceway or cable sheath. Where the box opening is smaller than 8 in. in any dimension, the conductor must also extend at least 3 in. outside the opening.
Reference: NFPA 70, National Electrical Code, 2023, 300.14
A Class 2 alarm cable is run near 120-volt power conductors in a stud wall, and none of the other separation options applies. What minimum separation must be kept?
Answer: 2 inches
Section 725.136(I) requires at least 50 mm (2 in.) between Class 2 or Class 3 conductors and light, power, Class 1 or non-power-limited fire alarm conductors, unless the power or Class 2 conductors are in a raceway or metal-sheathed cables, or a permanent nonconductor barrier is used. The 1/4 in. figure applies only inside enclosures for associated equipment.
Reference: NFPA 70, National Electrical Code, 2023, 725.136(I)
Class 2 and Class 3 conductors and electric light and power conductors must share one box. Which method is specifically permitted to separate them?
Answer: A barrier between the two groups of conductors
Section 725.136(B) allows Class 2 and Class 3 circuits to be installed together with light, power, Class 1 and non-power-limited fire alarm conductors where a barrier separates them. Colors, tape and straps do not provide the barrier.
Reference: NFPA 70, National Electrical Code, 2023, 725.136(B)
What does a passive infrared (PIR) motion detector respond to?
Answer: A change in infrared energy as a warm body moves across its zones
A PIR detector sends out nothing. Its lens divides the room into zones, and it alarms when a warm body moving between zones changes the infrared energy that the sensor sees. Detectors that transmit energy (microwave, ultrasonic) work differently.
Reference: General practice: burglar alarm systems, Intrusion detection: passive infrared detectors
Which location is the most likely to cause false alarms from a PIR motion detector?
Answer: Aimed across a sunny window or a hot-air register
Heat sources, sunlight and moving warm air create rapid infrared changes that look like an intruder to a PIR. Mount the detector on a stable surface at the manufacturer's recommended height, away from vents, heaters and direct sunlight.
Reference: General practice: burglar alarm systems, Intrusion detection: PIR false alarms
What is the characteristic of a 24-hour tamper zone?
Answer: It is active whether or not the system is armed
Tamper switches on enclosures and detectors, and panic or hold-up zones, are 24-hour zones that report at all times so that nobody can disable the system while it is disarmed. Entry/exit zones are the ones that use delays.
Reference: General practice: burglar alarm systems, Intrusion detection zones: 24-hour zones
Sources
- PSI: New Jersey Fire Alarm, Burglar Alarm and Locksmith exam registration and bulletin (updated 7/30/2026) (opens in a new tab)
- New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.