Requirements at a glance
| Agency | State Board of Examiners of Electrical Contractors (Division of Consumer Affairs); exams by PSI |
|---|---|
| Eligibility | Age 21 and five years of employment in electrical construction (see N.J.A.C. 13:31) |
| Exams | Electrical Contractor and Alarm Systems Electrical Contractor, plus Business and Law |
| Fees | $84 to PSI (Business and Law is $47), plus Board application and license fees |
Candidates for a New Jersey electrical contractor license from the State Board of Examiners of Electrical Contractors.
Official links
How to get licensed, step by step
Apply to the board
Get the Board's approval to test. It sends an Examination Eligibility Notice with instructions for paying and scheduling.
New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
Schedule the electrical contractor exam and Business and Law with PSI
Pay and schedule with PSI online or at (855) 340-3713. First-time candidates take all required exams on the same day. Fees are not refundable or transferable and are valid for one year.
Schedule with PSI (NJ electrical contractors) (opens in a new tab)
Retake if needed
Retake only the exams you failed, after the waiting period your board sets (6 months between attempts for most boards). Check your Eligibility Notice for the exact limits.
Schedule with PSI (NJ electrical contractors) (opens in a new tab)
Get licensed
PSI sends your results to the board. Contact the board for the license application, fees and insurance requirements.
New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
How to prepare
- Bring the exact editions on PSI's outline, and check the bulletin again before test day. New Jersey adopted newer codes in August 2026, but the exam bulletins still name the 2023 NEC, the 2021 National Standard Plumbing Code and the 2021 IMC and IFGC.
- First-time candidates take all required exams on the same day, so practice the trade exam and Business and Law together.
- You can highlight, underline and index books you bring, but not write in them. The 2023 NEC is provided at the electrical and alarm test centers.
- Grounding and bonding (16) is the largest section: tab NEC Article 250 and its tables.
- Motors and controls (12) mixes code and calculations from Articles 430 and 440.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the 2023 NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), 2023 EditionEssential
Most of the exam. Tab Articles 100, 110, 210, 220, 230, 240, 250, 310, 314, 430 and Chapter 9.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
Official reference list (as published by the testing agency)
- NFPA 70: National Electrical Code (NEC), 2023 Edition (provided at the test center; you can't use your own copy and may not mark the provided one)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| General Electrical Knowledge | 10 | |
| Raceways and Enclosures | 10 | |
| Services, Feeders, and Branch Circuits | 10 | |
| Overcurrent Protection | 5 | |
| Conductors and Cables | 9 | |
| Grounding and Bonding | 16 | |
| Equipment for General Use | 9 | |
| Special Occupancies | 5 | |
| Special Equipment and Conditions | 5 | |
| Motors and Controls | 12 | |
| Low Voltage and Communications Circuits | 6 | |
| Safety | 3 |
Exam day details
- Administered by PSI Services for the New Jersey Division of Consumer Affairs boards.
- Fee: $84 to PSI. Board application and license fees are separate.
- 100 questions in the time printed in the PSI bulletin (260 minutes; the bulletin notes a reduction to 255 minutes after June 1, 2017); 70 correct (70%) to pass.
- Code questions are based only on the 2023 NEC. The exam may also include trade knowledge and general industry practice.
- Electrical contractor candidates take the Electrical Contractor, Alarm Systems Electrical Contractor and Business and Law exams on the same day for the first attempt.
- After a failed first or second attempt, wait 6 months from the previous test date. You must pass all three exams within three attempts, and within 5 years of your eligibility date or you must reapply with the Board.
- Your board (or committee) must approve your application first and sends an Examination Eligibility Notice. Then you pay and schedule with PSI by phone at (855) 340-3713 or online.
- Exam fees are not refundable or transferable and are valid for one year from payment.
- References may be highlighted, underlined and indexed before the exam but not written in; loose or attached papers are not allowed. A book PSI provides at the test center can't be marked.
Frequently asked questions
What's on the New Jersey electrical contractor exam?
100 questions: grounding and bonding 16, motors and controls 12, general electrical knowledge 10, raceways and enclosures 10, services, feeders and branch circuits 10, conductors and cables 9, equipment for general use 9, low voltage and communications circuits 6, overcurrent protection 5, special occupancies 5, special equipment and conditions 5 and safety 3.
Which NEC edition does the New Jersey electrical contractor exam use?
The 2023 NEC. PSI provides the book at the test center and you can't bring your own.
How often can I retake it?
You get three attempts to pass all required exams, with 6 months between attempts, and you must pass within 5 years of your eligibility date.
Free questions with answers
Show all 10 free questions and answers
A 600 kcmil copper service-entrance conductor set has a grounding electrode conductor that connects only to a single driven ground rod and nothing else. What is the largest size copper GEC the Code requires?
Answer: 6 AWG copper
Table 250.66 would call for 1/0 copper for 600 kcmil, but 250.66(A) says that when the GEC goes only to rod, pipe or plate electrodes it is not required to be larger than 6 AWG copper. The 4 AWG limit belongs to concrete-encased electrodes in 250.66(B).
Reference: NFPA 70: National Electrical Code, 2023 Edition, 250.66(A)
A three-phase, 480-volt balanced load draws 25 A per line at a power factor of 1.0. What is the apparent power, using VA = 1.732 x E x I?
Answer: 20,784 VA
VA = 1.732 x 480 x 25 = 20,784 VA, about 20.8 kVA. Using E x I only gives 12,000 VA (single-phase), and multiplying by 3 instead of 1.732 gives 36,000 VA. Dividing by 1.732 instead of multiplying gives about 6,928 VA.
Reference: General trade practice: three-phase power, VA = 1.732 x E x I
A feeder is protected by a 400-ampere circuit breaker. In a field installation, 10-ft tap conductors leave the enclosure in which the tap is made and end at a single panelboard. Under 240.21(B)(1), what is the minimum ampacity the tap conductors must have based on the feeder device rating (in addition to the load and equipment-rating requirements)?
Answer: 40 A, one-tenth of the feeder overcurrent device rating
Under 240.21(B)(1)(3), for field installations where the tap conductors leave the enclosure or vault in which the tap is made, the tap ampacity must be at least one-tenth of the rating of the overcurrent device protecting the feeder: 400 / 10 = 40 A. The tap must also carry the calculated load and be not less than the rating of the device or equipment it supplies. The one-third figure belongs to the 25-ft tap rule in 240.21(B)(2).
Reference: NFPA 70: National Electrical Code, 2023 Edition, 240.21(B)(1)
A 20-in. long conduit nipple is installed between two boxes and carries nine 10 AWG THHN conductors (0.0211 sq in. each) in 1/2-in. EMT (total area 0.304 sq in.). According to Chapter 9 Table 1 Note 4, what percent fill is permitted, and does this nipple comply?
Answer: 60 percent (0.182 sq in.); it does not comply, since 0.190 sq in. is installed
Nipples not exceeding 24 in. between boxes may be filled to 60 percent of cross-sectional area, and the 310.15(C)(1) adjustment factors need not apply. 60 percent of 0.304 = 0.182 sq in. Nine 10 AWG conductors total 9 x 0.0211 = 0.190 sq in., which is more than 0.182, so the fill is not permitted.
Reference: NFPA 70: National Electrical Code, 2023 Edition, Chapter 9, Table 1, Note 4
Which service requires ground-fault protection of equipment under 230.95?
Answer: A 480Y/277-volt, 3-phase, 4-wire solidly grounded service with a 1,200 A main
Ground-fault protection of equipment is required for solidly grounded wye services of more than 150 volts to ground but not exceeding 1,000 volts phase-to-phase, for each service disconnect rated 1,000 A or more. 208Y/120 V is only 120 volts to ground, 800 A is below the threshold, and an ungrounded delta is not a solidly grounded wye.
Reference: NFPA 70: National Electrical Code, 2023 Edition, 230.95
Using the 75°C column of Table 310.16, what is the ampacity of a 4/0 AWG copper conductor?
Answer: 230 A
In Table 310.16 the 4/0 AWG copper entries are 195 A at 60°C, 230 A at 75°C and 260 A at 90°C. The aluminum 75°C value is 180 A. Termination limits usually make the 75°C column the working value.
Reference: NFPA 70: National Electrical Code, 2023 Edition, Table 310.16
Which location requires listed tamper-resistant 15- and 20-ampere, 125- and 250-volt nonlocking receptacles under 406.12?
Answer: A child care facility
Section 406.12 lists dwelling units, guest rooms of hotels and motels, child care facilities, preschools and education facilities, certain clinic and office spaces, waiting areas, gymnasiums, auditoriums and similar occupancies. Industrial production floors, parking garages and loading docks are not on the list.
Reference: NFPA 70: National Electrical Code, 2023 Edition, 406.12
What is the synchronous speed of an eight-pole, 60-hertz induction motor, using 120 x f / P?
Answer: 900 rpm
Synchronous speed = 120 x 60 / 8 = 900 rpm. Four poles give 1,800 rpm, six poles give 1,200 rpm and two poles give 3,600 rpm. Actual rotor speed is slightly below synchronous speed because of slip.
Reference: General trade practice: motor speed formula, Ns = 120 x f / P
What is the minimum number of receptacles required at each Category 2 patient bed location under 517.18(B)(1)?
Answer: Eight
Section 517.18(B)(1) requires a minimum of eight receptacles at each Category 2 patient bed location, all of them listed hospital grade and identified, with an insulated copper equipment grounding conductor sized per Table 250.122.
Reference: NFPA 70: National Electrical Code, 2023 Edition, 517.18(B)(1)
Where may Class 2 and Class 3 circuit conductors be installed in the same enclosure or raceway as electric light and power conductors under 725.136?
Answer: When they are separated by a barrier
Section 725.136(A) bars Class 2 and Class 3 circuits from sharing a cable, raceway, box or enclosure with light, power, Class 1 or non-power-limited fire alarm conductors, except as 725.136(B) through (I) allow, such as separation by a barrier or a raceway within the enclosure.
Reference: NFPA 70: National Electrical Code, 2023 Edition, 725.136(A), (B)
Sources
- PSI: New Jersey Electrical Contractor exam registration and bulletin (updated 3/5/2026) (opens in a new tab)
- New Jersey Division of Consumer Affairs: professional boards (opens in a new tab)
Questions last verified November 16, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.