Nevada licensing exam

Nevada C-3 Carpentry, Maintenance and Minor Repairs Exam: Practice Test & Licensing Guide

The PSI trade exam for Nevada's C-3 Carpentry license: 60 questions on rough and finish carpentry, drywall, doors and windows, siding and safety, with the 2018 IBC open book.

Questions
60
Time limit
2 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Rough Carpentry

Using IBC Table 2304.10.1, how must an end joint in a double top plate be nailed with 16d common nails?

Requirements at a glance

AgencyNevada State Contractors Board (NSCB); exams by PSI
Experience4 years as a journeyman, foreman, supervisor or contractor in the classification within the last 15 years (up to 3 years can be education)
Exams60 questions, 2 hours, 70%, plus the Construction Management Survey (business and law)
Books allowed2018 IBC
Fees$95 per PSI exam ($140 for a trade exam plus the CMS), plus NSCB application and license fees and a bond

Qualifying individuals for a Nevada C-3 Carpentry, Maintenance and Minor Repairs license (framing, rough and finish carpentry, cabinets, drywall, insulation and overhead doors).

How to get licensed, step by step

  1. Pick your classification

    Find the NSCB classification that covers your work, and name the qualifying individual (an owner or a qualified employee) with 4 years of experience in it.

    NSCB: License classifications (opens in a new tab)

  2. Apply to the NSCB

    Submit the application with your experience verification, financial statement and fingerprints. The Board sends you an exam eligibility notice once it accepts your qualifications.

    Nevada State Contractors Board (opens in a new tab)

  3. Schedule the CMS and C-3 trade exam with PSI

    Book both exams with PSI. Bring the allowed references, tabbed. If you fail, wait 2 weeks; you get three attempts and must pass within 6 months of filing.

    Schedule with PSI (Nevada contractors) (opens in a new tab)PSI: Nevada "C" classification bulletin and outlines (opens in a new tab)

  4. Post your bond and get licensed

    After you pass, the Board sets your monetary limit and bond amount ($1,000 to $500,000). File the bond and pay the license fee to receive your license.

How to prepare

  • Bring the exact editions on PSI's outline. Nevada's trade exams use the 2017 NEC, the 2018 IBC/IRC and the 2018 UPC/UMC; a newer book gives some wrong answers.
  • Tab your books with permanent tabs before exam day. Sticky notes are removed at check-in, and you can't write in the books.
  • OSHA 1926 isn't allowed in the room, but every trade exam has a safety section from it. Learn the common numbers (fall protection at 6 ft, ladders 3 ft above the landing, trenches 5 ft).
  • Rough carpentry is 23 of 60 questions: tab IBC Chapter 23 (wood), especially 2304 (fastening, decay protection) and 2308 (conventional framing).
  • Finish carpentry (14) and drywall (7) are mostly trade knowledge: trim joinery, fastening schedules and gypsum board application.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IBC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Building Code (IBC), 2018 (allowed in the exam room)
  • 29 CFR Part 1926, OSHA Construction (not allowed in the room)
  • Carpentry and Building Construction; BCSI truss guide; Gypsum Construction Handbook; Finish Carpenter's Manual (not allowed in the room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Safety6
Insulation1
Windows and Doors3
Rough Carpentry23
Finish Carpentry14
Drywall7
Siding2
Sheet Metal4

Exam day details

  • Administered by PSI Services for the Nevada State Contractors Board (NSCB).
  • Fee: $95 to PSI for one exam, $140 for a trade exam plus the CMS. NSCB application and license fees are separate.
  • 60 questions in 2 hours; 42 correct (70%) to pass.
  • Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed.
  • PSI may add up to 10 unscored trial questions, which count against your time.
  • If you fail, wait 2 weeks to retake. You get three attempts, and you must pass within 6 months of filing your application; a third failure voids the application.
  • Every Nevada contractor license needs both the Construction Management Survey (business and law) and the trade exam for the classification, plus 4 years of experience in the last 15.

Frequently asked questions

What's on the Nevada C-3 carpentry exam?

60 questions: rough carpentry 23, finish carpentry 14, drywall 7, safety 6, sheet metal 4, windows and doors 3, siding 2 and insulation 1.

What book can I bring to the C-3 exam?

Only the 2018 International Building Code. The carpentry, truss and drywall handbooks on PSI's list can't be brought in, so learn framing and finish practices beforehand.

Do I also need the business and law exam?

Yes. Every Nevada contractor license also needs the Construction Management Survey (CMS) business and law exam.

Free questions with answers

Show all 10 free questions and answers
  1. Using IBC Table 2304.10.1, how must an end joint in a double top plate be nailed with 16d common nails?

    Answer: 8 nails each side of the joint; 24-inch lap

    Item 13 of IBC Table 2304.10.1 (top plate to top plate, at end joints) calls for 8-16d common nails face-nailed on each side of the end joint, with a minimum 24-inch lap splice length each side. Twelve nails is the count when 10d box or 3 in. x 0.131 in. nails are used. Don't confuse the lap with the 48-inch end-joint offset in Section 2308.5.3.2.

    Reference: 2018 International Building Code, Table 2304.10.1, Item 13

  2. A 2x10 floor joist (actual depth 9-1/4 in.) must be notched on its top edge for a pipe, away from the joist ends and outside the middle third of the span. Under IBC 2308.4.2.4, what is the deepest notch allowed?

    Answer: About 1-1/2 inches

    IBC 2308.4.2.4 limits notches in the top or bottom of joists to one-sixth of the depth, and they may not be in the middle third of the span. 9.25 / 6 = 1.54 in., about 1-1/2 inches. About 2-5/16 in. (9.25 / 4) is the limit for notches at the joist ends, and about 3 in. (9.25 / 3) is the maximum bored-hole diameter.

    Reference: 2018 International Building Code, Section 2308.4.2.4

  3. Under IBC 2308.5.2, how many studs are required at each corner of an exterior wall, unless wood spacers or backup cleats are used for the wall finish?

    Answer: Three

    IBC 2308.5.2 requires not less than three studs at each corner of an exterior wall. The exception allows two studs where 3/8-in. wood structural panel, 3/8-in. Type M particleboard, 1-in. lumber cleats or other approved devices give backing for the facing materials, but not where fire-resistance ratings or shear values are involved unless specifically approved.

    Reference: 2018 International Building Code, Section 2308.5.2

  4. In a crawl space inside the foundation perimeter, the bottoms of the floor joists are 20 inches above the exposed ground and the bottom of a wood girder is 11 inches above it. Under IBC 2304.12.1.1, which members must be naturally durable or preservative-treated wood?

    Answer: The girder only

    IBC 2304.12.1.1 requires naturally durable or preservative-treated wood for joists or wood structural floors closer than 18 inches, and for girders closer than 12 inches, to exposed ground in crawl spaces. The joists at 20 inches are above the 18-inch trigger, so untreated joists are fine; the girder at 11 inches is under 12 inches, so it must be durable or treated.

    Reference: 2018 International Building Code, Section 2304.12.1.1

  5. A carpenter sets up a manufactured extension ladder with a working length of 16 feet from its foot to the top support. Under 29 CFR 1926.1053(b)(5)(i), about how far from the wall should the foot be?

    Answer: 4 feet

    29 CFR 1926.1053(b)(5)(i) requires non-self-supporting ladders to be set so the horizontal distance from the top support to the foot is about one-quarter of the working length: 16 / 4 = 4 ft. Two feet (16 / 8) is the one-eighth angle required only for wood job-made ladders with spliced side rails (b)(5)(ii); 5 ft 4 in. is one-third and 8 ft is one-half.

    Reference: 29 CFR Part 1926, 1926.1053(b)(5)(i)

  6. A carpenter is installing lever handles and a deadbolt used for normal operation on an office door. Under IBC 1010.1.9.2, within what height range above the finished floor must this hardware be installed?

    Answer: 34 to 48 inches

    IBC 1010.1.9.2 requires door handles, pulls, latches, locks and other operating devices to be installed 34 inches minimum and 48 inches maximum above the finished floor. Locks used only for security, not normal operation, may be at any height, and pool barrier gate latches may go up to 54 inches under the exception.

    Reference: 2018 International Building Code, Section 1010.1.9.2

  7. Vinyl siding is being installed horizontally on wood studs and the manufacturer's instructions give no fastener spacing. Under IBC 1404.14.1, what is the maximum horizontal spacing of the nails?

    Answer: 16 inches

    IBC 1404.14.1 says that, unless the approved instructions specify otherwise, horizontally installed vinyl siding is fastened at not more than 16 inches horizontally and 12 inches vertically (vertical siding: 12 in. both ways). Nails must be corrosion resistant with at least a 0.313-in. head and 1/8-in. shank, penetrating framing or nailing strip at least 3/4 inch.

    Reference: 2018 International Building Code, Section 1404.14.1

  8. Using the calculated method of IBC 722.6.2, what fire-resistance rating does a wall get with 2x4 wood studs at 16 in. o.c., one layer of 1/2-inch Type X gypsum wallboard on each side, and cavities completely filled with mineral wool batts meeting Table 722.6.2(5)?

    Answer: 60 minutes

    Per 722.6.2.1, add the fire-side membrane, the framing and any additional protection, but not the membrane on the unexposed side: 1/2-in. Type X = 25 min [Table 722.6.2(1)] + wood studs at 16 in. o.c. = 20 min [Table 722.6.2(2)] + filled mineral wool = 15 min [Table 722.6.2(5)] = 60 minutes. Leaving out the insulation gives 45; counting both membranes gives 85. Section 722.6.1.1 caps calculated ratings at 1 hour.

    Reference: 2018 International Building Code, Section 722.6.2.1; Tables 722.6.2(1), (2) and (5)

  9. Under IBC 1011.5.2, what are the maximum riser height and minimum tread depth for a stair in an office building (not a dwelling)?

    Answer: 7-inch riser; 11-inch tread

    IBC 1011.5.2 limits riser height to 7 inches maximum (4 inches minimum) and requires a minimum rectangular tread depth of 11 inches, measured nosing to nosing. The 7-3/4-inch riser and 10-inch tread are the exception for Group R-3 and within dwelling units of Group R-2.

    Reference: 2018 International Building Code, Section 1011.5.2

  10. An exterior patio's walking surface is 24 inches above grade at its edge. The ground slopes away so that at 40 inches out from the edge it is 33 inches below the patio surface, and within 36 inches it is never more than 30 inches below. Under IBC 1015.2, is a guard required?

    Answer: No; the only drop over 30 in. is beyond 36 in. horizontally

    IBC 1015.2 requires guards on open-sided walking surfaces located more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally of the open edge. Here the drop is no more than 30 inches anywhere within 36 inches; the 33-inch drop is 40 inches out, beyond the zone, so no guard is required. There is no 24-inch trigger, and 42 inches is the guard height, not the trigger.

    Reference: 2018 International Building Code, Section 1015.2

Sources

Questions last verified October 23, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.