No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Nevada One Call

A B-2 contractor plans to dig footings for a home addition next week. Under NRS 455.110, when must it notify the one-call association for operators?

Requirements at a glance

AgencyNevada State Contractors Board (NSCB); exams by PSI
Experience4 years as a journeyman, foreman, supervisor or contractor in the classification within the last 15 years (up to 3 years can be education)
Exams80 questions, 3 hours, 70%, plus the Construction Management Survey (business and law)
Books allowed2018 IRC, 2018 IBC and ACI 318
Fees$95 per PSI exam ($140 for a trade exam plus the CMS), plus NSCB application and license fees and a bond

Qualifying individuals for a Nevada B-2 Residential and Small Commercial license: houses and other buildings no more than three stories above ground and one below.

How to get licensed, step by step

  1. Pick your classification

    Find the NSCB classification that covers your work, and name the qualifying individual (an owner or a qualified employee) with 4 years of experience in it.

    NSCB: License classifications (opens in a new tab)

  2. Apply to the NSCB

    Submit the application with your experience verification, financial statement and fingerprints. The Board sends you an exam eligibility notice once it accepts your qualifications.

    Nevada State Contractors Board (opens in a new tab)

  3. Schedule the CMS and B-2 trade exam with PSI

    Book both exams with PSI. Bring the allowed references, tabbed. If you fail, wait 2 weeks; you get three attempts and must pass within 6 months of filing.

    Schedule with PSI (Nevada contractors) (opens in a new tab)PSI: Nevada "B" classification bulletin and outlines (opens in a new tab)

  4. Post your bond and get licensed

    After you pass, the Board sets your monetary limit and bond amount ($1,000 to $500,000). File the bond and pay the license fee to receive your license.

How to prepare

  • Bring the exact editions on PSI's outline. Nevada's trade exams use the 2017 NEC, the 2018 IBC/IRC and the 2018 UPC/UMC; a newer book gives some wrong answers.
  • Tab your books with permanent tabs before exam day. Sticky notes are removed at check-in, and you can't write in the books.
  • OSHA 1926 isn't allowed in the room, but every trade exam has a safety section from it. Learn the common numbers (fall protection at 6 ft, ladders 3 ft above the landing, trenches 5 ft).
  • Carpentry (12), concrete (10), masonry (10) and safety (10) are over half the exam. Tab IRC Chapters 4 (foundations), 5 (floors), 6 (walls) and 8 (roof framing).
  • Safety is 10 questions from OSHA 1926, which you can't bring in: fall protection, scaffolds, ladders and excavations.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the 2018 IRC and the 2018 IBC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • International Residential Code (IRC), 2018 (allowed in the exam room)
  • International Building Code (IBC), 2018 (allowed in the exam room)
  • ACI 318-11 or 318-14, Building Code Requirements for Structural Concrete (allowed in the exam room)
  • 29 CFR Part 1926, OSHA Construction (not allowed in the room)
  • Carpentry and Building Construction; Modern Masonry; Gypsum Construction Handbook; BCSI truss guide; Nevada One Call law (not allowed in the room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Sitework4
Concrete10
Masonry10
Metals5
Carpentry12
Thermal and Moisture Protection9
Doors and Windows3
Drywall and Finishes4
Safety10
General Code, Plan Reading and Estimating10
Nevada One Call3

Exam day details

  • Administered by PSI Services for the Nevada State Contractors Board (NSCB).
  • Fee: $95 to PSI for one exam, $140 for a trade exam plus the CMS. NSCB application and license fees are separate.
  • 80 questions in 3 hours; 56 correct (70%) to pass.
  • Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed.
  • PSI may add up to 10 unscored trial questions, which count against your time.
  • If you fail, wait 2 weeks to retake. You get three attempts, and you must pass within 6 months of filing your application; a third failure voids the application.
  • Every Nevada contractor license needs both the Construction Management Survey (business and law) and the trade exam for the classification, plus 4 years of experience in the last 15.

Frequently asked questions

What's on the Nevada B-2 exam?

80 questions: carpentry 12, concrete 10, masonry 10, safety 10, general code, plan reading and estimating 10, thermal and moisture protection 9, metals 5, sitework 4, drywall and finishes 4, doors and windows 3 and Nevada One Call 3.

What books can I bring to the Nevada B-2 exam?

The 2018 IRC, the 2018 IBC and ACI 318 (2011 or 2014). Safety questions come from OSHA 1926, which you can't bring in.

Do I also need the business and law exam?

Yes. Every Nevada contractor license also needs the Construction Management Survey (CMS) business and law exam.

Free questions with answers

Show all 10 free questions and answers
  1. A B-2 contractor plans to dig footings for a home addition next week. Under NRS 455.110, when must it notify the one-call association for operators?

    Answer: At least 2 working days but not more than 28 calendar days before digging

    NRS 455.110(1)(a) requires notice to the association for operators at least 2 working days but not more than 28 calendar days before excavation or demolition is scheduled to begin, giving the contractor's contact information, start date, duration, type of work, area and whether explosives will be used. Calling too early (more than 28 days) doesn't satisfy the law either.

    Reference: Nevada Revised Statutes, NRS 455.110(1)(a)

  2. A vented crawl space has 2,100 square feet of under-floor area, and the ground is bare soil (no Class I vapor retarder). Under IRC R408.1, what is the minimum net area of foundation vent openings?

    Answer: 14 square feet

    IRC R408.1 requires at least 1 sq ft of net vent area for each 150 sq ft of under-floor area unless the ground is covered with a Class I vapor retarder. 2,100 ÷ 150 = 14 sq ft. With a Class I vapor retarder the ratio drops to 1 per 1,500 sq ft (1.4 sq ft). 21 sq ft would use 1 per 100.

    Reference: 2018 International Residential Code, Section R408.1

  3. A detached garage slab is 30 ft by 40 ft and 4 inches thick. How many cubic yards of concrete does it contain, before waste?

    Answer: 14.8 cubic yards

    Volume = 30 × 40 × (4 ÷ 12) = 400 cubic feet. 400 ÷ 27 = 14.8 cubic yards. 177.8 forgets to convert inches to feet (30 × 40 × 4 ÷ 27), 44.4 divides by 9 instead of 27, and 16.3 adds 10% waste to the correct volume. A 4-inch slab also exceeds the IRC R506.1 minimum of 3-1/2 inches.

    Reference: 2018 International Residential Code, Section R506.1 (slab thickness); volume = L × W × T ÷ 27

  4. Grout for a reinforced block wall was batched at 9:00 a.m. Under IRC R606.3.5.1, by what time must it be placed?

    Answer: 10:30 a.m.

    IRC R606.3.5.1 requires grout to be placed before initial set and not more than 1-1/2 hours after water has been added: 9:00 a.m. + 1.5 hours = 10:30 a.m. The grout must also be consolidated by puddling or vibration and reconsolidated after excess water is absorbed, and it can't be pumped through aluminum pipe.

    Reference: 2018 International Residential Code, Section R606.3.5.1

  5. Stairs will connect floors with a total rise of 112 inches. Using the IRC maximum riser height of 7-3/4 inches and equal risers, what is the fewest number of risers that works, and what is each riser's height?

    Answer: 15 risers at about 7.47 inches

    Divide total rise by the maximum riser height: 112 ÷ 7.75 = 14.45, so round up to 15 risers. 112 ÷ 15 = 7.47 inches each, under the 7-3/4 inch maximum (IRC R311.7.5.1). Fourteen risers would be 8.0 inches each, too tall; 14 × 7.75 = 108.5 inches doesn't reach 112. Sixteen 7-inch risers would also comply but is not the fewest.

    Reference: 2018 International Residential Code, Section R311.7.5.1

  6. Under IRC R905.2.8.5, how must drip edge be installed on an asphalt shingle roof?

    Answer: At eaves and rakes, lapped at least 2 in., extending 1/4 in. below the sheathing and 2 in. onto the deck

    IRC R905.2.8.5 requires drip edge at eaves and rake edges of shingle roofs, with adjacent pieces overlapped at least 2 inches, extending at least 1/4 inch below the sheathing and at least 2 inches back onto the deck, and fastened at not more than 12 inches o.c. Underlayment goes over the drip edge at eaves and under it at rakes.

    Reference: 2018 International Residential Code, Section R905.2.8.5

  7. Framers are sheathing the second-floor deck of a new house. At what height above a lower level does OSHA require guardrails, safety nets or personal fall arrest for residential construction?

    Answer: 6 feet

    29 CFR 1926.501(b)(13) requires each employee in residential construction 6 feet or more above a lower level to be protected by guardrails, safety nets or personal fall arrest, unless the employer shows those are infeasible or create a greater hazard and uses a written fall protection plan. Ten feet is the scaffold threshold (1926.451(g)(1)).

    Reference: 29 CFR Part 1926, 1926.501(b)(13)

  8. A second-story bedroom casement window has a net clear opening 22 inches wide by 36 inches high and a sill 40 inches above the floor. Does it meet the IRC emergency escape requirements?

    Answer: No; the clear area is only 5.5 sq ft, under the 5.7 sq ft required

    Clear area = 22 × 36 = 792 sq in ÷ 144 = 5.5 sq ft, below the 5.7 sq ft required above grade (IRC R310.2.1), even though the 22-inch width and 36-inch height exceed the 20- and 24-inch minimums. The 40-inch sill is within the 44-inch maximum (R310.2.2). Every one of the limits must be met.

    Reference: 2018 International Residential Code, Sections R310.2.1 and R310.2.2

  9. An attached garage has a bedroom above it. Under IRC Table R302.6, what gypsum board must go on the garage ceiling?

    Answer: 5/8-inch Type X gypsum board or equivalent

    IRC Table R302.6 requires not less than 5/8-inch Type X gypsum board (or equivalent) on the garage ceiling where habitable rooms are above the garage. Separation from the residence and its attic otherwise needs at least 1/2-inch gypsum board on the garage side, and structure supporting a floor/ceiling assembly used for separation needs at least 1/2-inch gypsum board.

    Reference: 2018 International Residential Code, Table R302.6

  10. A 12 ft × 14 ft bedroom relies on windows for light and ventilation. Under IRC R303.1, what are the minimum glazing area and openable area?

    Answer: 13.44 sq ft glazing; 6.72 sq ft openable

    Floor area = 12 × 14 = 168 sq ft. IRC R303.1 requires aggregate glazing of at least 8% of the floor area (168 × 0.08 = 13.44 sq ft) and an openable area to the outdoors of at least 4% (168 × 0.04 = 6.72 sq ft), unless mechanical ventilation and artificial light are provided under the exceptions. 16.8 sq ft uses 10%.

    Reference: 2018 International Residential Code, Section R303.1