Nevada licensing exam

Nevada A General Engineering Contractor Exam: Practice Test & Licensing Guide

The PSI trade exam for Nevada's A General Engineering license: 100 questions on concrete, paving, excavation, piping, fuel systems, steel, welding, traffic control and power lines, open book.

Questions
100
Time limit
3 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Water and Piping

A new public water main is designed for a northern Nevada site where the frost depth is 30 inches. Under NAC 445A.67145(3)(b), what minimum cover is required over the pipe?

Requirements at a glance

AgencyNevada State Contractors Board (NSCB); exams by PSI
Experience4 years as a journeyman, foreman, supervisor or contractor in the classification within the last 15 years (up to 3 years can be education)
Exams100 questions, 3 hours, 70%, plus the Construction Management Survey (business and law)
Books allowedNDEP fact sheets WTS-22/23, NFPA 30 (2018) and ASME B31.8 (2018)
Fees$95 per PSI exam ($140 for a trade exam plus the CMS), plus NSCB application and license fees and a bond

Qualifying individuals for a Nevada A General Engineering license (fixed works such as roads, utilities, pipelines, sewers, bridges and site work).

How to get licensed, step by step

  1. Pick your classification

    Find the NSCB classification that covers your work, and name the qualifying individual (an owner or a qualified employee) with 4 years of experience in it.

    NSCB: License classifications (opens in a new tab)

  2. Apply to the NSCB

    Submit the application with your experience verification, financial statement and fingerprints. The Board sends you an exam eligibility notice once it accepts your qualifications.

    Nevada State Contractors Board (opens in a new tab)

  3. Schedule the CMS and A trade exam with PSI

    Book both exams with PSI. Bring the allowed references, tabbed. If you fail, wait 2 weeks; you get three attempts and must pass within 6 months of filing.

    Schedule with PSI (Nevada contractors) (opens in a new tab)PSI: Nevada "A" classification bulletin and outlines (opens in a new tab)

  4. Post your bond and get licensed

    After you pass, the Board sets your monetary limit and bond amount ($1,000 to $500,000). File the bond and pay the license fee to receive your license.

How to prepare

  • Bring the exact editions on PSI's outline. Nevada's trade exams use the 2017 NEC, the 2018 IBC/IRC and the 2018 UPC/UMC; a newer book gives some wrong answers.
  • Tab your books with permanent tabs before exam day. Sticky notes are removed at check-in, and you can't write in the books.
  • OSHA 1926 isn't allowed in the room, but every trade exam has a safety section from it. Learn the common numbers (fall protection at 6 ft, ladders 3 ft above the landing, trenches 5 ft).
  • Concrete, paving, excavation and fuel piping are half the exam. Most of it comes from references you can't bring in, so study OSHA Subpart P (excavations), asphalt paving practice and pipe bedding.
  • Nevada One Call (3) and traffic control (3) are quick points: know the 2-working-day notice and the work-zone basics of the MUTCD.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • NDEP Bureau of Water Pollution Control fact sheets WTS-22 and WTS-23 (allowed in the exam room)
  • NFPA 30, Flammable and Combustible Liquids Code, 2018 (allowed in the exam room)
  • ASME B31.8, Gas Transmission and Distribution Piping Systems, 2018 (allowed in the exam room)
  • 29 CFR Part 1926, OSHA Construction (not allowed in the room)
  • NDOT Standard Specifications for Road and Bridge Construction; Hot-Mix Asphalt Paving Handbook; DIPRA ductile iron pipe guide; Pipe and Excavation Contracting; Placing Reinforcing Bars; Lineman's and Cableman's Handbook; Nevada One Call law (not allowed in the room)

What's on the exam

Official content outline from PSI Services (number of questions per topic):

TopicQuestions
Sewers4
Water and Piping11
Gas and Liquid Fuel Piping12
Paving12
Excavation, Compaction and Grading12
Safety7
Steel6
Piles4
Concrete14
Traffic Control3
Welding6
NV One-Call3
Electrical Transmission Lines6

Exam day details

  • Administered by PSI Services for the Nevada State Contractors Board (NSCB).
  • Fee: $95 to PSI for one exam, $140 for a trade exam plus the CMS. NSCB application and license fees are separate.
  • 100 questions in 3 hours; 70 correct (70%) to pass.
  • Open book: bring your own copies of the allowed references. You may highlight and add permanent tabs beforehand, but not write in them; sticky notes are removed.
  • PSI may add up to 10 unscored trial questions, which count against your time.
  • If you fail, wait 2 weeks to retake. You get three attempts, and you must pass within 6 months of filing your application; a third failure voids the application.
  • Every Nevada contractor license needs both the Construction Management Survey (business and law) and the trade exam for the classification, plus 4 years of experience in the last 15.

Frequently asked questions

What's on the Nevada A General Engineering exam?

100 questions: concrete 14, gas and liquid fuel piping 12, paving 12, excavation, compaction and grading 12, water and piping 11, safety 7, steel 6, welding 6, electrical transmission lines 6, sewers 4, piles 4, traffic control 3 and Nevada One Call 3.

What books can I bring to the Nevada A exam?

Only the NDEP fact sheets WTS-22 and WTS-23, NFPA 30 (2018) and ASME B31.8 (2018). Most questions come from the paving, pipe, concrete and OSHA references you study beforehand but can't bring in.

Do I also need the business and law exam?

Yes. Every Nevada contractor license also needs the Construction Management Survey (CMS) business and law exam.

Free questions with answers

Show all 10 free questions and answers
  1. A new public water main is designed for a northern Nevada site where the frost depth is 30 inches. Under NAC 445A.67145(3)(b), what minimum cover is required over the pipe?

    Answer: 42 inches

    NAC 445A.67145(3)(b) requires water mains to have at least 36 inches of cover or to be at least 12 inches below frost depth, whichever is deeper. Here 30 + 12 = 42 inches, which is deeper than 36 inches, so 42 inches governs. 36 inches is right only where the frost depth is 24 inches or less. 30 inches puts the pipe right at the frost line, and 24 inches is the gas-main cover in 49 CFR 192.327(b).

    Reference: Nevada Administrative Code Chapter 445A (NDEP public water system regulations), NAC 445A.67145(3)(b)

  2. Under 29 CFR 1926.651(c)(2), a trench 4 feet or more deep must have a ladder, stairway, ramp or other safe means of egress within how much lateral travel of every worker?

    Answer: 25 feet

    1926.651(c)(2) requires a stairway, ladder, ramp or other safe means of egress in trench excavations 4 feet or more deep, placed so that no employee has to travel more than 25 feet laterally to reach it. On a long pipe trench, that means moving the ladder with the crew or providing several ladders.

    Reference: 29 CFR Part 1926, 1926.651(c)(2)

  3. A crane will set manholes near a 12.47 kV overhead distribution line. Under 29 CFR 1926.1408 Table A, what is the minimum clearance distance?

    Answer: 10 feet

    Table A in 1926.1408 lists 10 feet for nominal voltages up to 50 kV, and 12.47 kV falls in that row. 15 feet applies over 50 to 200 kV and 20 feet over 200 to 350 kV. Under 1926.1408(a)(2), the employer may instead keep the equipment 20 feet away (Option 2), or use the Table A distance with the added precautions of Option 3.

    Reference: 29 CFR Part 1926, 1926.1408, Table A

  4. A 10-foot-deep sewer trench in Type B soil is simple-sloped on both sides at the Appendix B maximum slope. The bottom is 4 feet wide. What is the minimum width at the top?

    Answer: 24 feet

    Appendix B, Figure B-1.2 allows a maximum slope of 1:1 (H:V) for simple-slope excavations 20 feet or less deep in Type B soil. Each side runs back 1 × 10 = 10 feet, so top width = 4 + 10 + 10 = 24 feet. 14 feet slopes only one side. 19 feet uses the Type A 3/4:1 slope (4 + 7.5 + 7.5), and 34 feet uses the Type C 1-1/2:1 slope (4 + 15 + 15).

    Reference: 29 CFR Part 1926, Part 1926 Subpart P, Appendix B, Figure B-1.2

  5. Under IBC Table 1808.8.2, what is the minimum concrete cover over reinforcement in a cast-in-place deep foundation element that is NOT enclosed by a steel pipe, tube or permanent casing?

    Answer: 2.5 inches

    Table 1808.8.2 row 4 requires 2.5 inches of cover for cast-in-place deep foundation elements not enclosed by a steel pipe, tube or permanent casing. When enclosed by a steel pipe or casing (row 5), only 1 inch is required. 1.5 inches applies to drilled shafts in a stable rock socket (row 7), and 3 inches applies to precast nonprestressed elements exposed to seawater.

    Reference: 2018 International Building Code, Table 1808.8.2

  6. A steel gas transmission line is buried in normal soil through a Class 3 location. Under the table in 49 CFR 192.327(a), what is the minimum cover?

    Answer: 36 inches

    The 192.327(a) table requires 36 inches in normal soil (24 inches in consolidated rock) for Class 2, 3 and 4 locations and for drainage ditches at public roads and railroad crossings. Class 1 locations need 30 inches in normal soil and 18 inches in rock. 48 inches is the cover for navigable rivers, streams and harbors in 192.327(e).

    Reference: 49 CFR Part 192, 192.327(a)

  7. Steel pipe for a gas transmission line is 12.75 inches OD with a 0.250-inch wall and 52,000 psi yield strength, in a Class 2 location. Using 49 CFR 192.105 with E = 1.0 and T = 1.0, what is the design pressure?

    Answer: About 1,224 psig

    192.105: P = (2St/D) × F × E × T. 2 × 52,000 × 0.250 = 26,000; 26,000 ÷ 12.75 = 2,039.2 psi. The Class 2 design factor in the 192.111 table is F = 0.60, so P = 2,039.2 × 0.60 × 1.0 × 1.0 = 1,223.5, about 1,224 psig. 1,468 uses the Class 1 factor (0.72), 1,020 uses the Class 3 factor (0.50), and 612 leaves the 2 out of the formula.

    Reference: 49 CFR Part 192, 192.105(a) and 192.111(a)

  8. Vertical dowels stick up from a newly poured footing where workers could fall onto them. Under 29 CFR 1926.701(b), what is required?

    Answer: Guarding the bars to eliminate impalement

    1926.701(b) requires all protruding reinforcing steel onto and into which employees could fall to be guarded to eliminate the impalement hazard, typically with rebar caps or troughs rated for impalement protection. Paint and signs only warn; they do not protect a falling worker.

    Reference: 29 CFR Part 1926, 1926.701(b)

  9. An airport apron is paved under FAA Item P-403 with a 2.5-inch asphalt mat. Under paragraph 403-4.1, Table 4, what is the minimum surface temperature of the underlying course?

    Answer: 45°F

    P-403-4.1 prohibits placing asphalt on a wet surface or when the underlying surface is colder than Table 4 allows. Table 4 requires 45°F for mats thicker than 2 inches but less than 3 inches, and 40°F for mats 3 inches or thicker. Thin mats lose heat faster, so they need a warmer base to reach density before the mix cools. The RPR may waive the temperature limit on request, but density and other requirements still apply.

    Reference: FAA Advisory Circular 150/5370-10H, Standard Specifications for Construction of Airports (2018), Item P-403, paragraph 403-4.1 and Table 4

  10. Under FAA Item P-403, paragraph 403-4.11, by how much must transverse joints in one asphalt course be offset from transverse joints in the previous course?

    Answer: 10 feet

    P-403-4.11 requires transverse joints in one course to be offset at least 10 feet from transverse joints in the previous course, and transverse joints in adjacent lanes to be offset at least 10 feet as well. 1 foot is the minimum offset for longitudinal joints between courses. Under 403-4.13, a transverse joint is formed with a bulkhead or a taper that is cut back to a vertical face and tacked before paving resumes.

    Reference: FAA Advisory Circular 150/5370-10H, Standard Specifications for Construction of Airports (2018), Item P-403, paragraphs 403-4.11 and 403-4.13

Sources

Questions last verified October 23, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.