Minnesota licensing exam

Minnesota Residential Remodeler Exam: Practice Test & Licensing Guide

The Minnesota DLI residential remodeler (QC) exam: 110 questions on the 2020 Minnesota Residential Code and Minnesota statutes. Open book, 5.5 hours, 70% to pass.

Questions
110
Time limit
5.5 hours
Passing score
70%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Plans and Specifications

A remodeler is framing a new straight interior partition 24 feet long with studs 16 inches on center, one stud at each end and no openings or corners. How many studs are needed for the straight run, counting the end studs?

Requirements at a glance

AgencyMinnesota Department of Labor and Industry (DLI)
ExperienceNo experience requirement listed in the DLI exam guide; see DLI for the license rules (Minn. Stat. 326B.805)
Exam110 questions (about 60 scored on the code outline), 5.5 hours, 70% to pass
Books allowedNone of your own: DLI supplies the 2020 Minnesota Residential Code, statutes and rules and a calculator
Fees$50 per personal-license exam (Minn. Stat. 326B.092), plus application and license fees

Contractors applying to DLI for a residential remodeler license (Minn. Stat. 326B.805).

How to get licensed, step by step

  1. Apply to DLI

    Send DLI your residential remodeler license and exam application. After you pass, you must also meet the bond and insurance requirements before DLI issues the license.

    Minnesota Department of Labor and Industry (DLI) (opens in a new tab)DLI: residential building contractor, remodeler and roofer (opens in a new tab)

  2. Schedule your exam

    After DLI approves your application, you schedule the exam in DLI's iMS system. DLI gives exams at its St. Paul office (Tuesday to Thursday) and at outstate sites including Duluth, Mankato, Rochester and St. Cloud.

    DLI: license exam schedule (opens in a new tab)

  3. Take the exam

    You have 5.5 hours and need 70%. The exam is open book with DLI-supplied references; no personal books, notes or electronic devices.

    DLI: residential building contractor, remodeler and roofer (opens in a new tab)DLI Residential Examination Guide (PDF) (opens in a new tab)

  4. Results and retakes

    DLI mails results in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.

    DLI: license exam schedule (opens in a new tab)

How to prepare

  • The residential exams are on the 2020 Minnesota Residential Code (Rules 1309, based on the 2018 IRC) and the 2020 Residential Energy Code, plus Minnesota statutes and rules. About 60 of the 110 questions are scored on the code content outline; the rest cover business, law and technical topics.
  • DLI rates the Building Contractor exam hardest, then the Remodeler and Roofer exams. Know the Minnesota amendments, not just the model IRC.
  • Every DLI exam is open book, but with DLI-supplied references only: a code book without tabs, the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, so practice finding answers fast rather than relying on tabs.
  • DLI publishes no topic weights, so our topic split is an estimate. Several versions of each exam are in use, and some questions ask for more than one answer or the choice that does not apply.
  • The remodeler outline matches the building contractor's through Interior Finishes: replacement windows, egress, energy envelope and framing are common remodel topics.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the Minnesota Residential Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • 2020 Minnesota Residential Code, Minnesota Rules chapter 1309 (the 2018 International Residential Code with Minnesota amendments), and the 2020 Minnesota Residential Energy Code
  • Minnesota Rules chapters 1300, 1303, 1315, 1322, 1350 and 1360 and Minnesota Statutes 176, 181, 326B, 327A, 333 and 514 (in the DLI laws-and-rules booklet)
  • DLI supplies the references and a desk calculator; you cannot bring your own.

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Plans and Specifications4
Energy Code (Envelope Criteria)5
Building Planning and Life Safety7
Sitework4
Concrete and Masonry Footings and Foundations6
Carpentry14
Roofing6
Exterior Finishes5
Foam Plastic Insulation4
Interior Finishes5

Exam day details

  • Administered by the Minnesota Department of Labor and Industry (DLI), which gives its own exams.
  • Fee: $50 per personal-license exam (Minn. Stat. 326B.092). Application and license fees are separate.
  • 110 questions in 5.5 hours; 70% to pass. About 60 of the 110 are scored on the code content outline; the rest cover business, law and technical topics DLI does not itemize. All questions are multiple choice with five options.
  • DLI publishes the outline but no topic weights, so our topic split is an estimate of the 60 code-content questions. DLI rechecks scores within 5 percentage points of passing.
  • The three residential exams are separate: the Remodeler exam uses the building contractor outline without its last two areas, and the Roofer exam has its own roofing outline. DLI rates the Building Contractor exam hardest.
  • Open book with DLI-supplied references: you get the code book (without tabs), the DLI laws-and-rules booklet and a desk calculator. You cannot bring your own books, notes or electronic devices.
  • DLI gives the exam at its St. Paul office and outstate sites, scheduled after DLI approves your application. The time limit is 5.5 hours; the passing score is 70%.
  • Results are mailed in about 2 weeks. If you fail, wait 30 days after receiving results before reapplying.
  • Some questions ask you to pick more than one answer (the question says how many) or the one choice that does not apply. Several versions of each exam are in use.

Note: DLI's residential guide (06/2020) prints the outline but no topic weights, so our topic split is an estimate. Our questions follow the 2020 Minnesota Residential Code (the 2018 IRC as amended by Rules 1309); the energy questions use Rules 1322, since we did not have the 2012 IECC text on file.

Frequently asked questions

How is the remodeler exam different from the building contractor exam?

Its outline runs through Interior Finishes (areas I to X) and leaves out the associated issues and job site safety areas. DLI rates the building contractor exam harder.

How many questions are on it?

110 questions in 5.5 hours; 70% to pass. About 60 are scored on the code content outline.

What if I fail?

Wait 30 days after you receive your results, then reapply with a new application and fees.

Free questions with answers

Show all 10 free questions and answers
  1. A remodeler is framing a new straight interior partition 24 feet long with studs 16 inches on center, one stud at each end and no openings or corners. How many studs are needed for the straight run, counting the end studs?

    Answer: 19

    24 ft x 12 in./ft = 288 in. 288 / 16 = 18 spaces, and the run needs one more stud than spaces: 18 + 1 = 19. Eighteen forgets the last stud; 25 uses 12 inch spacing (288/12 + 1); 20 adds an arbitrary extra.

    Reference: Minnesota Rules, chapter 1300, 1300.0130 subp. 2

  2. Under the Minnesota Residential Code, what is the minimum ceiling height for a new habitable room with a flat ceiling, measured from the finished floor to the lowest projection from the ceiling?

    Answer: 7 feet

    Minn. R. 1309.0305 (amending IRC R305.1) requires habitable space, hallways, bathrooms, toilet rooms and laundry rooms in new buildings to have a ceiling height of at least 7 feet, measured to the lowest projection from the ceiling. The 6 feet 8 inch figure applies only to specific exceptions, such as clearances at bathroom fixtures and non-habitable basement portions.

    Reference: Minnesota Rules, chapter 1309, 1309.0305 (amending IRC R305.1)

  3. Where physical barriers prevent 6 inches of fall in 10 feet, R401.3 allows a driveway or patio within 10 feet of the foundation to be sloped away at a minimum of 2 percent. How much total drop does 2 percent give across 10 feet of horizontal run?

    Answer: 2.4 inches

    2 percent is 0.02 ft of drop per ft of run. 10 ft x 0.02 = 0.2 ft, and 0.2 ft x 12 in./ft = 2.4 inches. The 1.2 inch answer is 1 percent, 0.2 inches mixes feet and inches, and 6 inches is the general 10 foot fall requirement for soil grade, not the impervious-surface exception.

    Reference: 2018 International Residential Code, R401.3 Exception

  4. What minimum 28-day compressive strength does the Minnesota amendment to Table R402.2 specify for concrete footings (without the admixture option in footnote g)?

    Answer: 5,000 psi

    Minn. R. 1309.0402 amends Table R402.2 to require 5,000 psi for footings in all weathering potentials. Footnote g allows 2,500 psi concrete with an approved admixture giving water and vapor resistance equal to 5,000 psi concrete, and footnote h exempts deck and porch post footings, wood foundations, slab-on-grade foundation walls and floating-slab footings. Basement walls need 2,500 psi.

    Reference: Minnesota Rules, chapter 1309, 1309.0402 (amending Table R402.2)

  5. A remodeler adds a new bedroom. Under IRC Table R301.5, the floor live load for a sleeping room is 30 psf. For floor joists spaced 16 inches on center, what live load does each linear foot of joist carry?

    Answer: 40 pounds per linear foot

    Table R301.5 gives 30 psf for sleeping rooms (40 psf for other rooms). A joist at 16 in. on center carries a strip 16/12 = 1.333 ft wide, so 30 psf x 1.333 ft = 40 plf. Using 30 plf ignores the spacing, 53 plf mistakenly applies the 40 psf living-area load (40 x 1.333).

    Reference: 2018 International Residential Code, Table R301.5

  6. Ice barrier underlayment is required on a new asphalt shingle roof (slope below 8:12) over a heated house in Minnesota. The eave overhangs the exterior wall by 12 inches measured horizontally. R905.1.2 requires the barrier to extend from the eave edge to a point at least 24 inches inside the exterior wall line; treat that 24 inches as a horizontal (plan) distance. What minimum horizontal distance from the eave edge must the barrier cover?

    Answer: 36 inches

    R905.1.2 requires the ice barrier to extend from the lowest edge of the roof to at least 24 inches inside the exterior wall line. Read as a horizontal distance (the same section separately says the 8:12 rule is measured along the roof slope), the covered horizontal distance is 12 in. (overhang) + 24 in. (inside the wall) = 36 inches. Twenty-four inches forgets the overhang. Minnesota's amended Table R301.2(1) (Minn. R. 1309.0301) enters Yes for ice barrier underlayment required. On slopes of 8:12 or more, the barrier must also cover at least 36 inches measured along the slope.

    Reference: 2018 International Residential Code, R905.1.2; Minn. R. 1309.0301 (Table R301.2(1))

  7. A contractor is replacing an existing window in an older Minnesota house. Under the Minnesota amended R703.4.1, is pan flashing at the sill required?

    Answer: No; repair or replacement of existing windows and doors is an exception

    Minn. R. 1309.0703 lists exceptions to pan flashing, including Exception 5: repairs or replacement of existing windows and doors. Other exceptions cover windows or doors installed per manufacturer instructions with an alternate flashing method, detached accessory structures, skylights, bow or bay windows, accessible doors where pan flashing would prevent compliance, and designs by a registered design professional.

    Reference: Minnesota Rules, chapter 1309, 1309.0703 (R703.4.1, exception 5)

  8. Unless R316.5 allows otherwise, what surface-burning limits must foam plastic used in building construction meet under IRC R316.3?

    Answer: Flame spread index of 75 or less and smoke-developed index of 450 or less

    R316.3 limits foam plastic to a flame spread index of not more than 75 and a smoke-developed index of not more than 450 when tested per ASTM E84 or UL 723 at the maximum thickness and density intended. The 200 value is the flame spread limit for interior wall and ceiling finishes (R302.9.1), and the 25 value is the limit for spray foam at sill plates and headers (R316.5.11).

    Reference: 2018 International Residential Code, R316.3

  9. A remodeler is building a new wood frame addition in Minnesota Climate Zone 6 and uses the prescriptive path. Under Minn. R. 1322.0402 (Table R402.1.1), which wall insulation options are listed for a wood frame wall?

    Answer: R-20 cavity, or R-13 cavity plus R-5 continuous insulation

    Table R402.1.1 as amended in Minn. R. 1322.0402 lists, for Climate Zone 6, a wood frame wall R-value of 20 or 13+5, where the first number is cavity insulation and the second is continuous insulation or insulated siding. Zone 7 lists R-21. R-13 cavity insulation alone does not meet either option.

    Reference: Minnesota Rules, chapter 1322, 1322.0402 subp. 1 (Table R402.1.1)

  10. Which material is listed in Table R702.4.2 as an acceptable backer for wall tile in a tub or shower area?

    Answer: Nonasbestos fiber-cement backer board

    Table R702.4.2 lists glass mat gypsum backing panel (ASTM C1178), fiber-reinforced gypsum panels (C1278), nonasbestos fiber-cement backer board (C1288 or ISO 8336 Category C) and nonasbestos fiber mat-reinforced cementitious backer units (C1325). Water-resistant gypsum backing board may not be used where there will be direct exposure to water or continuous high humidity (R702.3.7.1), and neither standard interior gypsum board nor plywood is a listed tile backer.

    Reference: 2018 International Residential Code, Table R702.4.2; R702.3.7.1

Sources

Questions last verified November 9, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.