Requirements at a glance
| Agency | Michigan LARA, Bureau of Construction Codes; exam by PSI |
|---|---|
| Exam | 55 questions, 1 hour, 75% to pass |
| Books allowed | 2021 Michigan Mechanical Code, 2015 Michigan Residential Code, ASHRAE 15 and 34 (2022), UL/CSA 60335-2-40 and -89, PA 407 and PA 230, as allowed by LARA's reference list |
| Fees | $50 to PSI per attempt, plus LARA application and license fees |
| Experience | At least 3 years or 6,000 hours of experience in the classification, backed by sworn statements from your contractor-of-record employers; a 2-year HVAC program can count for up to 1 year or 2,000 hours (MCL 339.5807) |
Anyone applying to LARA for the refrigeration classification of a Michigan mechanical contractor license.
Official links
How to get licensed, step by step
Apply to LARA
Submit your mechanical contractor application for the refrigeration classification. LARA approves you before you can pay for the exam.
Michigan LARA: Bureau of Construction Codes (opens in a new tab)
Schedule with PSI
Follow your approval letter to book. Retests are unlimited within the year at $50 each.
Schedule with PSI (Michigan mechanical) (opens in a new tab)PSI: Michigan mechanical contractor candidate bulletin (opens in a new tab)
Check the book list
The bulletin points to LARA's mechanical reference materials list. Bring bound, unmarked copies of the allowed editions.
PSI: Michigan mechanical contractor candidate bulletin (opens in a new tab)
How to prepare
- Bring only what the bulletin allows. Michigan reference books must be bound and unmarked: no highlighting, underlining or loose papers.
- Michigan's codes are the 2021 Michigan Plumbing Code and Mechanical Code (the 2021 IPC and IMC with Michigan amendments) and the 2015 Michigan Residential Code. Study the Michigan text, not the model code.
- Learn the Mechanical Code refrigeration chapter, refrigerant piping practice and walk-in cooler basics; the ASHRAE and UL standards are not in our source set, so those topics are general practice.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Michigan Mechanical Code and the Michigan Residential Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 Michigan Mechanical Code (2021 IMC with Michigan amendments)Essential
Allowed in the HVAC Equipment exam room. Ducts, ventilation, exhaust, combustion air and appliance installation.
2015 Michigan Residential CodeEssential
Listed in the HVAC Equipment bulletin and as a study reference for the residential builder exam.
Skilled Trades Regulation Act, 2016 PA 407
Free online from the Michigan Legislature. The licensing law for plumbers and mechanical contractors; shown on screen in the plumbing exams.
Stille-DeRossett-Hale Single State Construction Code Act, 1972 PA 230
Free online from the Michigan Legislature. Permits, inspections and code enforcement; law questions draw on it.
Official reference list (as published by the testing agency)
- 2021 Michigan Mechanical Code and 2015 Michigan Residential Code, and related referenced standards
- ASHRAE 15-2022 and ASHRAE 34-2022
- UL/CSA 60335-2-40 (2022) and UL/CSA 60335-2-89 (2021)
- Skilled Trades Regulation Act, 2016 PA 407 and State Construction Code Act, 1972 PA 230
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Commercial Refrigeration Equipment and Systems | 15 | |
| Refrigerant Piping and Joints | 10 | |
| Valves, Filter Driers, Sight Glasses and Receivers | 8 | |
| Walk-in Coolers and Freezers | 6 | |
| Refrigerants and Safety | 5 | |
| Codes and Standards | 7 | |
| Skilled Trades Regulation Act and State Construction Code Act | 4 |
Exam day details
- Administered by PSI Services for the Michigan Department of Licensing and Regulatory Affairs (LARA), Bureau of Construction Codes.
- Fee: $50 to PSI per attempt, non-refundable and valid for one year. LARA application and license fees are separate.
- 55 questions listed in the bulletin table with 1 hour allowed; 75% to pass. The bulletin text mentions 50 questions in one place; we follow the table.
- The bulletin describes the content but gives no per-topic weights. Our topic weights are an estimate that adds up to 55 and include the PA 407 and PA 230 law questions every mechanical exam carries.
- Content covers commercial refrigeration systems for other than air conditioning, including walk-in coolers and freezers from 1 to 10 HP, refrigerant piping with brazed, silver-soldered and flared joints, and valves, filter driers, sight glasses and receivers.
- This exam is separate from the federal EPA 608 certification.
- The bulletin sends you to LARA's Mechanical Contractor Licensing Exam Reference Materials list (rev. 8/1/2024) for what you may bring. Reference books must be bound and unmarked.
- If you fail you may retest an unlimited number of times within the year, paying the fee each attempt.
- The Department (LARA BCC) must approve your application first. It sends a notification letter with instructions to pay and schedule with PSI; only the State decides eligibility.
- PSI may add up to ten unscored experimental questions; they are not counted in your score and don't take time from the exam.
- Cancel or reschedule at least 2 days before the appointment to keep your fee; late cancellations and no-shows forfeit it.
Frequently asked questions
What's on the Michigan refrigeration exam?
55 questions on commercial refrigeration equipment and systems, refrigerant piping and joints, valves, driers, sight glasses and receivers, walk-in coolers and freezers, refrigerants and safety, and codes, plus 2016 PA 407 and 1972 PA 230.
Does it replace EPA 608?
No. EPA 608 is a separate federal certification for handling refrigerants.
How much does it cost?
$50 to PSI per attempt. LARA application and license fees are separate.
Free questions with answers
Show all 10 free questions and answers
What does MCL 339.5803(b) say about "limited refrigeration and air conditioning service"?
Answer: It is servicing of refrigeration and air conditioning systems of unlimited capacity that use group 1 refrigerants
Section 803(b) limits this classification by refrigerant, not capacity: unlimited capacity, group 1 refrigerants as listed in the Michigan mechanical code. Section 803(h) is the unlimited version, unlimited as to capacity or refrigerant type.
Reference: 2016 PA 407, Skilled Trades Regulation Act (MCL 339.5801 et seq.), MCL 339.5803(b) and (h)
A refrigerant circuit contains 250 pounds of R-404A (Group A1), and the owner wants to convert it to a different Group A1 refrigerant. What does Section 1101.7 require?
Answer: Prior notice to the code official and compliance with the rules for the new refrigerant
Section 1101.7 requires prior notification and compliance for a change of refrigerant type in a circuit holding more than 220 lb of Group A1 or more than 30 lb of any other group. At 250 lb the A1 limit of 220 lb is exceeded, and the section does not exempt a swap within the same group. The 1,100 lb figure belongs to Section 1104.3.3.
Reference: 2021 Michigan Mechanical Code, Section 1101.7
Which gas does Section 1108.3.1 allow as the inert gas to purge and fill copper refrigerant piping while it is being brazed?
Answer: Oxygen-free nitrogen
Section 1108.3.1 requires purging air from the piping and filling it with oxygen-free nitrogen, helium or argon during brazing. Air contains oxygen and causes scale inside the tube; acetylene is a fuel gas and carbon dioxide is not on the list for brazing (it is allowed only as a test medium for R-744 systems).
Reference: 2021 Michigan Mechanical Code, Section 1108.3.1
While a joint is being brazed, what pressure range must the inert gas flowing through the piping be held to under Section 1108.3.1?
Answer: A minimum of 1.0 psi and a maximum of 3.0 psi
After the pre-purge, Section 1108.3.1 requires the inert gas supply to be maintained through the piping during brazing at a minimum of 1.0 psi and a maximum of 3.0 psi. Higher pressure can blow molten filler out of the joint, and lower pressure may let air in.
Reference: 2021 Michigan Mechanical Code, Section 1108.3.1
A field-erected system contains 40 pounds of refrigerant and has no pumpout provision. Under Section 1109.8.1, where must stop valves be installed?
Answer: At the compressor suction inlet, the compressor discharge outlet and the outlet of each liquid receiver
Section 1109.8.1 applies to systems with more than 6.6 lb of refrigerant. Stop valves go at the suction inlet and the discharge outlet of each compressor, compressor unit or condensing unit and at the outlet of each liquid receiver. Section 1109.8 exceptions (pumpout capability, recovery provisions, self-contained listed systems) are not present in this system.
Reference: 2021 Michigan Mechanical Code, Sections 1109.8 and 1109.8.1
Section 1109.8.4 requires identification of stop valves where their purpose is not obvious. If a numbering system is used, where must the legend be located?
Answer: In the room containing the indoor refrigeration equipment, with lettering at least 1/2 inch high
Section 1109.8.4 requires a legend or key for a valve numbering or lettering system to be in the room that contains the indoor refrigeration equipment, with identification lettering at least 1/2 inch (12.7 mm) high.
Reference: 2021 Michigan Mechanical Code, Section 1109.8.4
Under Section 1102.2.1, what is the rule on mixing refrigerants with different ASHRAE 34 designations in a system?
Answer: They must not be mixed, except a second refrigerant the maker allows for oil return
Section 1102.2.1 prohibits mixing refrigerants and blends that have different ASHRAE 34 designations. The only exception is the manufacturer-permitted addition of a second refrigerant, in the manufacturer's amount, to improve oil return at low temperatures.
Reference: 2021 Michigan Mechanical Code, Section 1102.2.1
Under Table 1101.2, which standards apply to commercial refrigerators, freezers, beverage coolers and walk-in coolers?
Answer: UL 471 or UL/CSA 60335-2-89
Table 1101.2 lists UL 471 or UL/CSA 60335-2-89 for commercial refrigerators, freezers, beverage coolers and walk-in coolers. The -2-40 standard goes with air conditioning equipment, and UL 412 is for unit coolers.
Reference: 2021 Michigan Mechanical Code, Table 1101.2
Section 1103.3 classifies refrigeration systems by the probability that leaked refrigerant could reach an occupied area. Which system is a high-probability system?
Answer: A direct system, with the evaporator in the cooled space
Section 1103.3.2 classifies direct systems and indirect open-spray systems as high probability (an indirect open-spray system is excepted if the secondary coolant pressure always exceeds the refrigerant pressure). Section 1103.3.1 treats double-indirect open-spray, indirect closed and indirect-vented closed systems as low probability when the refrigerant piping is isolated.
Reference: 2021 Michigan Mechanical Code, Sections 1103.3.1 and 1103.3.2
Which installation is exempt from the machinery room requirement in Section 1104.2 when the circuit exceeds the Table 1103.1 quantity?
Answer: Listed equipment holding 6.6 pounds or less, installed per its listing
The first exception to Section 1104.2 says machinery rooms are not required for listed equipment and appliances containing not more than 6.6 lb (3 kg) of refrigerant, regardless of safety classification, installed per the listing and manufacturer's instructions. A second exception allows piping per Section 1107 to connect machinery room components with outdoor ones.
Reference: 2021 Michigan Mechanical Code, Section 1104.2, Exceptions
Sources
- PSI: Michigan Mechanical Contractor Examinations Candidate Information Bulletin (opens in a new tab)
- Michigan LARA: Bureau of Construction Codes (opens in a new tab)
- LARA: PSI examinations for the Bureau of Construction Codes (opens in a new tab)
- LARA: Michigan code books and adopted codes (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.