Requirements at a glance
| Agency | Michigan LARA, Bureau of Construction Codes; exam by PSI |
|---|---|
| Exam | 55 questions, 1 hour, 75% to pass |
| Books allowed | 2021 Michigan Mechanical Code, 2015 Michigan Residential Code, ASME B31.3 (2022), PA 407 and PA 230, as allowed by LARA's reference list |
| Fees | $50 to PSI per attempt, plus LARA application and license fees |
| Experience | At least 3 years or 6,000 hours of experience in the classification, backed by sworn statements from your contractor-of-record employers; a 2-year HVAC program can count for up to 1 year or 2,000 hours (MCL 339.5807) |
Anyone applying to LARA for the hydronic heating and cooling and process piping classification of a Michigan mechanical contractor license.
Official links
How to get licensed, step by step
Apply to LARA
Submit your mechanical contractor application for the hydronic heating and cooling and process piping classification. LARA approves you before you can pay for the exam.
Michigan LARA: Bureau of Construction Codes (opens in a new tab)
Schedule with PSI
Follow your approval letter to book. Retests are unlimited within the year at $50 each.
Schedule with PSI (Michigan mechanical) (opens in a new tab)PSI: Michigan mechanical contractor candidate bulletin (opens in a new tab)
Check the book list
The bulletin points to LARA's mechanical reference materials list. Bring bound, unmarked copies of the allowed editions.
PSI: Michigan mechanical contractor candidate bulletin (opens in a new tab)
How to prepare
- Bring only what the bulletin allows. Michigan reference books must be bound and unmarked: no highlighting, underlining or loose papers.
- Michigan's codes are the 2021 Michigan Plumbing Code and Mechanical Code (the 2021 IPC and IMC with Michigan amendments) and the 2015 Michigan Residential Code. Study the Michigan text, not the model code.
- Radiant, baseboard and boiler piping are the core; know boiler trim, expansion tanks, air removal and the Michigan Mechanical Code hydronic chapter.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Michigan Mechanical Code and the Michigan Residential Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 Michigan Mechanical Code (2021 IMC with Michigan amendments)Essential
Allowed in the HVAC Equipment exam room. Ducts, ventilation, exhaust, combustion air and appliance installation.
2015 Michigan Residential CodeEssential
Listed in the HVAC Equipment bulletin and as a study reference for the residential builder exam.
Skilled Trades Regulation Act, 2016 PA 407
Free online from the Michigan Legislature. The licensing law for plumbers and mechanical contractors; shown on screen in the plumbing exams.
Stille-DeRossett-Hale Single State Construction Code Act, 1972 PA 230
Free online from the Michigan Legislature. Permits, inspections and code enforcement; law questions draw on it.
Official reference list (as published by the testing agency)
- 2021 Michigan Mechanical Code and 2015 Michigan Residential Code, and related referenced standards
- ASME B31.3, 2022 (process piping)
- Skilled Trades Regulation Act, 2016 PA 407 and State Construction Code Act, 1972 PA 230
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Hydronic Heating and Cooling Equipment and Systems | 15 | |
| Process Piping | 8 | |
| Controls and Components | 7 | |
| Combustion Air | 4 | |
| Gas Piping | 6 | |
| Venting | 5 | |
| Codes and Standards | 6 | |
| Skilled Trades Regulation Act and State Construction Code Act | 4 |
Exam day details
- Administered by PSI Services for the Michigan Department of Licensing and Regulatory Affairs (LARA), Bureau of Construction Codes.
- Fee: $50 to PSI per attempt, non-refundable and valid for one year. LARA application and license fees are separate.
- 55 questions listed in the bulletin table with 1 hour allowed; 75% to pass. The bulletin text mentions 50 questions in one place; we follow the table.
- The bulletin describes the content but gives no per-topic weights. Our topic weights are an estimate that adds up to 55 and include the PA 407 and PA 230 law questions every mechanical exam carries.
- Content covers residential boilers fired by natural gas, propane and fuel oil from 60,000 to 1,000,000 BTU, radiant baseboard and in-floor hydronic piping and piping materials such as welded steel, threaded Schedule 40, copper, PEX with press fittings, brazed and soldered joints.
- The bulletin sends you to LARA's Mechanical Contractor Licensing Exam Reference Materials list (rev. 8/1/2024) for what you may bring. Reference books must be bound and unmarked.
- If you fail you may retest an unlimited number of times within the year, paying the fee each attempt.
- The Department (LARA BCC) must approve your application first. It sends a notification letter with instructions to pay and schedule with PSI; only the State decides eligibility.
- PSI may add up to ten unscored experimental questions; they are not counted in your score and don't take time from the exam.
- Cancel or reschedule at least 2 days before the appointment to keep your fee; late cancellations and no-shows forfeit it.
Frequently asked questions
What's on the Michigan hydronic piping exam?
55 questions on installing hydronic heating and cooling equipment and systems, process piping, controls and components, combustion air, gas piping, venting and codes and standards, plus 2016 PA 407 and 1972 PA 230.
How much does it cost?
$50 to PSI per attempt. LARA application and license fees are separate.
Which standard covers process piping?
The reference list names ASME B31.3 (2022). We don't have that standard's text, so questions on it stick to general practice.
Free questions with answers
Show all 10 free questions and answers
A commercial hot water heating system has a maximum design pressure of 80 psi. Under Section 1208.1 of the Michigan Mechanical Code, to what pressure must it be hydrostatically tested?
Answer: 120 psi
Section 1208.1 requires a hydrostatic test at 1.5 times the maximum system design pressure, but not less than 100 psi. 1.5 x 80 = 120 psi, which exceeds the 100 psi floor. Testing at 100 psi would be the minimum-only mistake; 80 psi ignores the multiplier, and 160 psi doubles the pressure.
Reference: 2021 Michigan Mechanical Code, 1208.1
A low-temperature hydronic system has a maximum design pressure of 50 psi. What is the minimum hydrostatic test pressure under Section 1208.1 of the Michigan Mechanical Code?
Answer: 100 psi
The test is 1.5 times design pressure but never less than 100 psi. 1.5 x 50 = 75 psi, which is below the floor, so the 100 psi minimum governs. Testing at 75 psi forgets the minimum; 150 psi triples the design pressure.
Reference: 2021 Michigan Mechanical Code, 1208.1
A boiler nameplate shows a maximum allowable working pressure of 30 psi. At what pressure may the safety relief valve be set under Section 1006.4 of the Michigan Mechanical Code?
Answer: Not greater than 30 psi
Section 1006.4 requires listed and labeled safety and safety relief valves with rated capacity for the equipment served, set at not greater than the nameplate pressure rating of the boiler. A valve set above the rating would let the boiler exceed its design pressure.
Reference: 2021 Michigan Mechanical Code, 1006.4
Two natural gas boilers rated 400,000 Btu/h and 350,000 Btu/h are served by a single steel pipe run 50 feet long from the point of delivery to the most remote boiler. Gas is 1,000 Btu per cubic foot, pressure less than 2 psi, 0.5 in. w.c. drop. Using Table 402.4(2) of the IFGC (longest length method), what is the smallest Schedule 40 pipe size that serves the full load?
Answer: 1-1/2 inch
Demand = (400,000 + 350,000) / 1,000 = 750 cubic feet per hour (Section 402.2 sums the inputs). At the 50 foot row of Table 402.4(2), 1-1/4 inch carries 583 cfh, which is short, and 1-1/2 inch carries 873 cfh, which is enough. 1 inch carries only 284 cfh. 2 inch (1,680) would work but is not the smallest.
Reference: 2021 International Fuel Gas Code (adopted by the Michigan Mechanical Code), Table 402.4(2)
Appliances totaling 150,000 Btu/h are in a room that borrows air from a space on a different story through permanent openings in a door or floor. What total minimum free area applies under Section 304.5.3.2 of the IFGC?
Answer: 300 square inches
Section 304.5.3.2 treats spaces on different stories as communicating where permanent openings in doors or floors have a total free area of at least 2 square inches per 1,000 Btu/h. 150 x 2 = 300 square inches. Using 1 square inch per 1,000 Btu/h gives 150, which is the same-story rate.
Reference: 2021 International Fuel Gas Code (adopted by the Michigan Mechanical Code), 304.5.3.2
A boiler's vent connector is to be joined to a masonry chimney flue. At what height must the connection be made under Section 501.9 of the IFGC?
Answer: Not less than 12 inches above the lowest interior portion of the flue
Section 501.9 requires connectors to enter a masonry chimney flue at a point not less than 12 inches above the lowest portion of the interior of the flue, leaving room below for debris. The Michigan Mechanical Code gives the same 12 inches in Section 801.12.
Reference: 2021 International Fuel Gas Code (adopted by the Michigan Mechanical Code), 501.9
For Michigan mechanical contractor licensing, which of these is process piping under the definition in MCL 339.5803?
Answer: Piping that moves chemicals or other fluids for systems that are not air conditioning
Section 803(c) of 2016 PA 407 (MCL 339.5803) defines process piping as any piping that is not part of a system designed to provide air conditioning or part of a refrigeration system, such as pipes that carry chemicals and other fluids, gases or vapors for non-air-conditioning systems. Heating, chilled water and refrigerant piping are covered by the hydronic and refrigeration definitions instead.
Reference: MCL 339.5803 (2016 PA 407, Skilled Trades Regulation Act), MCL 339.5803(c)
How must steam piping be pitched under Section 1206.8 of the Michigan Mechanical Code?
Answer: To drain to the boiler or steam trap, with no capacity-reducing drip pockets
Section 1206.8 requires steam piping to be installed to drain to the boiler or the steam trap, and says steam systems shall not have drip pockets that reduce the capacity of the steam piping.
Reference: 2021 Michigan Mechanical Code, 1206.8
When may a gas or electric utility connection be made to a new boiler installation that needs a permit, under Section 110.1 of the Michigan Mechanical Code?
Answer: Only after the code official authorizes the connection
Section 110.1 prohibits connecting a utility, source of energy, fuel or power to any building or system regulated by the code and requiring a permit until authorized by the code official. Section 110.2 allows temporary connection for testing.
Reference: 2021 Michigan Mechanical Code, 110.1
What experience does MCL 339.5807(1)(a) require for an applicant to be eligible for a mechanical work classification examination?
Answer: At least 3 years or 6,000 hours in the classification
Section 807(1)(a) requires a minimum of 3 years or 6,000 hours of experience (or an equivalent acceptable to the board) in the classification sought, shown by a statement under penalty of perjury from each contractor of record employer.
Reference: 2016 PA 407, Skilled Trades Regulation Act (MCL 339.5801 et seq.), MCL 339.5807(1)(a)
Sources
- PSI: Michigan Mechanical Contractor Examinations Candidate Information Bulletin (opens in a new tab)
- Michigan LARA: Bureau of Construction Codes (opens in a new tab)
- LARA: PSI examinations for the Bureau of Construction Codes (opens in a new tab)
- LARA: Michigan code books and adopted codes (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.