Requirements at a glance
| Agency | Michigan LARA, Bureau of Construction Codes; exam by PSI |
|---|---|
| Exam | 55 questions, 1 hour, 75% to pass |
| Books allowed | 2021 Michigan Mechanical Code, 2015 Michigan Residential Code, 2021 IFGC, NFPA 58 (2020), PA 407 and PA 230, as allowed by LARA's reference list |
| Fees | $50 to PSI per attempt, plus LARA application and license fees |
| Experience | At least 3 years or 6,000 hours of experience in the classification, backed by sworn statements from your contractor-of-record employers; a 2-year HVAC program can count for up to 1 year or 2,000 hours (MCL 339.5807) |
| Two exams | PSI gives Fuel Gas Piping and Fuel Gas Piping and Venting as separate $50 exams; our bank covers both |
Anyone applying to LARA to install fuel gas piping, or fuel gas piping and venting, under a Michigan mechanical contractor license.
Official links
How to get licensed, step by step
Apply to LARA
Submit your mechanical contractor application for the fuel gas piping, or fuel gas piping and venting classification. LARA approves you before you can pay for the exam.
Michigan LARA: Bureau of Construction Codes (opens in a new tab)
Schedule with PSI
Follow your approval letter to book. Retests are unlimited within the year at $50 each.
Schedule with PSI (Michigan mechanical) (opens in a new tab)PSI: Michigan mechanical contractor candidate bulletin (opens in a new tab)
Check the book list
The bulletin points to LARA's mechanical reference materials list. Bring bound, unmarked copies of the allowed editions.
PSI: Michigan mechanical contractor candidate bulletin (opens in a new tab)
How to prepare
- Bring only what the bulletin allows. Michigan reference books must be bound and unmarked: no highlighting, underlining or loose papers.
- Michigan's codes are the 2021 Michigan Plumbing Code and Mechanical Code (the 2021 IPC and IMC with Michigan amendments) and the 2015 Michigan Residential Code. Study the Michigan text, not the model code.
- Practice gas pipe sizing with the IFGC tables, CSST and underground plastic rules, and Type B and Type L vent sizing.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the Michigan Mechanical Code and the Michigan Residential Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
2021 Michigan Mechanical Code (2021 IMC with Michigan amendments)Essential
Allowed in the HVAC Equipment exam room. Ducts, ventilation, exhaust, combustion air and appliance installation.
2015 Michigan Residential CodeEssential
Listed in the HVAC Equipment bulletin and as a study reference for the residential builder exam.
2021 International Fuel Gas Code (IFGC)
Allowed in the HVAC Equipment exam room. Gas piping sizing, venting and appliance installation.
Skilled Trades Regulation Act, 2016 PA 407
Free online from the Michigan Legislature. The licensing law for plumbers and mechanical contractors; shown on screen in the plumbing exams.
Stille-DeRossett-Hale Single State Construction Code Act, 1972 PA 230
Free online from the Michigan Legislature. Permits, inspections and code enforcement; law questions draw on it.
Official reference list (as published by the testing agency)
- 2021 Michigan Mechanical Code and 2015 Michigan Residential Code, and related referenced standards
- International Fuel Gas Code (IFGC), 2021
- NFPA 58 (2020), liquefied petroleum gas
- Skilled Trades Regulation Act, 2016 PA 407 and State Construction Code Act, 1972 PA 230
What's on the exam
Estimated topic weighting. No official breakdown is published:
| Topic | Questions | |
|---|---|---|
| Fuel Gas Piping Installation | 15 | |
| Piping Materials, Valves and Fittings | 10 | |
| Gas Pipe Sizing | 8 | |
| Venting Systems | 10 | |
| Codes and Standards | 8 | |
| Skilled Trades Regulation Act and State Construction Code Act | 4 |
Exam day details
- Administered by PSI Services for the Michigan Department of Licensing and Regulatory Affairs (LARA), Bureau of Construction Codes.
- Fee: $50 to PSI per attempt, non-refundable and valid for one year. LARA application and license fees are separate.
- 55 questions listed in the bulletin table with 1 hour allowed; 75% to pass. The bulletin text mentions 50 questions in one place; we follow the table.
- The bulletin describes the content but gives no per-topic weights. Our topic weights are an estimate that adds up to 55 and include the PA 407 and PA 230 law questions every mechanical exam carries.
- PSI lists Fuel Gas Piping and Fuel Gas Piping and Venting as two exams, each 55 questions and $50. This bank covers both; the venting topic applies to the second exam.
- Content covers complete gas piping systems from 1/2 inch to 4 inches in black iron, copper, corrugated stainless steel tubing (CSST) and underground plastic, and venting including Type B and Type L, stainless steel and PVC venting.
- The bulletin sends you to LARA's Mechanical Contractor Licensing Exam Reference Materials list (rev. 8/1/2024) for what you may bring. Reference books must be bound and unmarked.
- If you fail you may retest an unlimited number of times within the year, paying the fee each attempt.
- The Department (LARA BCC) must approve your application first. It sends a notification letter with instructions to pay and schedule with PSI; only the State decides eligibility.
- PSI may add up to ten unscored experimental questions; they are not counted in your score and don't take time from the exam.
- Cancel or reschedule at least 2 days before the appointment to keep your fee; late cancellations and no-shows forfeit it.
Frequently asked questions
What's on the Michigan fuel gas piping exam?
55 questions on installing fuel gas piping, valves and fittings from the point of delivery to the appliance inlet, pipe sizing, venting for the combined exam, and codes, plus 2016 PA 407 and 1972 PA 230.
What's the difference between the two fuel gas exams?
Fuel Gas Piping covers the piping only. Fuel Gas Piping and Venting adds the installation of vents from the appliance to the outside. Each is its own $50 PSI exam; this practice bank covers both.
Which books can I bring?
Check LARA's mechanical reference materials list. It names the Michigan Mechanical Code, the Michigan Residential Code, the 2021 IFGC and NFPA 58 (2020) for fuel gas.
Free questions with answers
Show all 10 free questions and answers
A gas service line must reach a house with a full basement. Under IFGC Section 404.6, how may the pipe pass through the foundation wall?
Answer: It may not penetrate the foundation wall below grade; the pipe enters and exits above grade with the annular space at the wall sealed
Section 404.6 prohibits gas piping from penetrating building foundation walls at any point below grade. The pipe must enter and exit the building above grade, and the space between pipe and wall must be sealed. Wrapping or heavier pipe does not change the rule.
Reference: International Fuel Gas Code (IFGC), 2021, Section 404.6
Which fitting is NOT permitted in a concealed location in a gas piping system under IFGC Section 404.5?
Answer: A threaded union
Section 404.5 limits concealed fittings to threaded elbows, tees, couplings, plugs and caps, plus brazed fittings, welded fittings and fittings listed to ANSI LC-1/CSA 6.26 or LC-4/CSA 6.32. A union is not on the list, because it is a joint that may need service.
Reference: International Fuel Gas Code (IFGC), 2021, Section 404.5
Which pipe material is not permitted for fuel gas piping under IFGC Section 403.3?
Answer: Cast-iron pipe
Section 403.3.1 states cast-iron pipe shall not be used for fuel gas. Steel, stainless steel and wrought-iron pipe are allowed (403.3.2) if not lighter than Schedule 10 and meeting listed ASTM standards.
Reference: International Fuel Gas Code (IFGC), 2021, Section 403.3.1
Gas tubing joints are to be brazed. What does IFGC Section 403.9.2 require of the brazing alloy?
Answer: Melting point above 1,000 degrees F and not over 0.05 percent phosphorus
Section 403.9.2 (and 403.9.1 for pipe) requires brazing materials with a melting point above 1,000 degrees F (538 C), and alloys with no more than 0.05 percent phosphorus. Soft solder is not acceptable for gas joints.
Reference: International Fuel Gas Code (IFGC), 2021, Section 403.9.2
A house has an 80,000 Btu/h furnace, a 40,000 Btu/h water heater, a 65,000 Btu/h range and a 25,000 Btu/h dryer, all on natural gas at 1,000 Btu per cubic foot. Under IFGC Section 402.2, what total demand is used to size the main supply piping?
Answer: 210 cubic feet per hour
Section 402.2 bases sizing on the sum of maximum inputs, assuming all appliances run at full capacity at once unless diversity can be established. 80,000 + 40,000 + 65,000 + 25,000 = 210,000 Btu/h; at 1,000 Btu/ft3 that is 210 cfh. The other choices omit one or more appliances.
Reference: International Fuel Gas Code (IFGC), 2021, Section 402.2
A rooftop unit needs 380 cfh of natural gas, and the longest run from the meter is 100 feet. The design allows a 0.5 in. w.c. pressure drop. Which Schedule 40 size does IFGC Table 402.4(2) require, at minimum?
Answer: 1-1/4 inch
The 100-foot row of Table 402.4(2) gives 1/2-inch 50 cfh, 3/4-inch 104 cfh, 1-inch 195 cfh, 1-1/4-inch 400 cfh and 1-1/2-inch 600 cfh. 380 cfh exceeds 195, so 1-1/4 inch (400 cfh) is the smallest that will do.
Reference: International Fuel Gas Code (IFGC), 2021, Table 402.4(2)
Two draft-hood appliances share one Type B gas vent. The larger draft hood outlet is 28 square inches and the smaller is 12 square inches. Under IFGC Section 503.6.10.1, what is the minimum effective area of the vent?
Answer: 34 square inches
For two appliances with draft hoods, the vent area must be at least the larger draft hood outlet plus 50 percent of the smaller: 28 + (0.5 x 12) = 34 sq in. It may not exceed seven times the smaller outlet (7 x 12 = 84 sq in). Adding both areas (40) oversizes it.
Reference: International Fuel Gas Code (IFGC), 2021, Section 503.6.10.1
A vent serves a single draft-hood appliance with a 4-inch draft hood outlet. Under IFGC Section 503.6.10.1, the effective area of the vent may not be greater than how many times the draft hood outlet area?
Answer: 7 times
Section 503.6.10.1 sizes a vent for a single draft-hood appliance at not less than the draft hood outlet area and not greater than seven times that area; the vent connector is sized the same way.
Reference: International Fuel Gas Code (IFGC), 2021, Section 503.6.10.1
Where does the IFGC coverage of a fuel gas piping system end under Section 101.2.2?
Answer: At the outlet of the appliance shutoff valves
Section 101.2.2 extends coverage from the point of delivery to the outlet of the appliance shutoff valves. Appliance connectors are handled by Section 411 and the appliance's own gas train falls under the manufacturer's listing.
Reference: International Fuel Gas Code (IFGC), 2021, Section 101.2.2
May a city require its own local license in addition to the state mechanical contractor license for work in the classifications of MCL 339.5807(2)?
Answer: No; a municipality may not establish or maintain local licensing for those classifications
MCL 339.5811 states a municipality shall not establish or maintain local licensing requirements for the mechanical work classifications. Section 339.5817 instead lets a municipality require the licensed contractor to register the state license for a fee of no more than $15.
Reference: Skilled Trades Regulation Act (2016 PA 407), MCL 339.5811
Sources
- PSI: Michigan Mechanical Contractor Examinations Candidate Information Bulletin (opens in a new tab)
- Michigan LARA: Bureau of Construction Codes (opens in a new tab)
- LARA: PSI examinations for the Bureau of Construction Codes (opens in a new tab)
- LARA: Michigan code books and adopted codes (opens in a new tab)
Questions last verified November 14, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.