Michigan licensing exam

Michigan Mechanical Ductwork Exam: Practice Test & Licensing Guide

The PSI exam for the ductwork classification of Michigan's mechanical contractor license: 55 questions on supply, return and exhaust air distribution, chimneys, flues, vents and codes. Open book, 75% to pass.

Questions
55
Time limit
60 min
Passing score
75%

Full practice test: $19One-time payment · 12 months of access

Try 10 free practice questions

No sign-up. Every answer explains the rule and tells you where to find it in your book.

Question 1 of 10Supply and Return Air Distribution

In a dwelling unit where the kitchen and living area are one open room and the cooking appliance is electric, what is the minimum distance from the appliance to a return air intake opening under the Michigan Mechanical Code?

Requirements at a glance

AgencyMichigan LARA, Bureau of Construction Codes; exam by PSI
Exam55 questions, 1 hour, 75% to pass
Books allowed2021 Michigan Mechanical Code, 2015 Michigan Residential Code, SMACNA duct standards, ACCA Manual J, PA 407 and PA 230, as allowed by LARA's reference list
Fees$50 to PSI per attempt, plus LARA application and license fees
ExperienceAt least 3 years or 6,000 hours of experience in the classification, backed by sworn statements from your contractor-of-record employers; a 2-year HVAC program can count for up to 1 year or 2,000 hours (MCL 339.5807)

Anyone applying to LARA for the ductwork classification of a Michigan mechanical contractor license.

How to get licensed, step by step

  1. Apply to LARA

    Submit your mechanical contractor application for the ductwork classification. LARA approves you before you can pay for the exam.

    Michigan LARA: Bureau of Construction Codes (opens in a new tab)

  2. Schedule with PSI

    Follow your approval letter to book. Retests are unlimited within the year at $50 each.

    Schedule with PSI (Michigan mechanical) (opens in a new tab)PSI: Michigan mechanical contractor candidate bulletin (opens in a new tab)

  3. Check the book list

    The bulletin points to LARA's mechanical reference materials list. Bring bound, unmarked copies of the allowed editions.

    PSI: Michigan mechanical contractor candidate bulletin (opens in a new tab)

How to prepare

  • Bring only what the bulletin allows. Michigan reference books must be bound and unmarked: no highlighting, underlining or loose papers.
  • Michigan's codes are the 2021 Michigan Plumbing Code and Mechanical Code (the 2021 IPC and IMC with Michigan amendments) and the 2015 Michigan Residential Code. Study the Michigan text, not the model code.
  • Know duct support and sealing, clearances, exhaust duct rules and chimney and vent basics from the Mechanical Code.
  • Start with the free questions above to find your weak topics, then drill those first.
  • Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
  • Read every explanation, including for questions you got right, and look the section up in your own book.

Books for this exam

This is an open-book exam: you can bring the references below, and most questions come from the Michigan Mechanical Code and the Michigan Residential Code. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.

Official reference list (as published by the testing agency)
  • 2021 Michigan Mechanical Code and 2015 Michigan Residential Code, and related referenced standards
  • ANSI/SMACNA 006-2020 HVAC Duct Construction Standards, Metal and Flexible (4th edition); the list also names the 2005 third edition and SMACNA Fibrous Glass Duct Construction Standards (7th edition, 2010)
  • ACCA Manual J (2011)
  • Skilled Trades Regulation Act, 2016 PA 407 and State Construction Code Act, 1972 PA 230

What's on the exam

Estimated topic weighting. No official breakdown is published:

TopicQuestions
Supply and Return Air Distribution18
Exhaust Duct Systems9
Chimneys, Flues and Vents10
Duct Types and Materials6
Codes and Standards8
Skilled Trades Regulation Act and State Construction Code Act4

Exam day details

  • Administered by PSI Services for the Michigan Department of Licensing and Regulatory Affairs (LARA), Bureau of Construction Codes.
  • Fee: $50 to PSI per attempt, non-refundable and valid for one year. LARA application and license fees are separate.
  • 55 questions listed in the bulletin table with 1 hour allowed; 75% to pass. The bulletin text mentions 50 questions in one place; we follow the table.
  • The bulletin describes the content but gives no per-topic weights. Our topic weights are an estimate that adds up to 55 and include the PA 407 and PA 230 law questions every mechanical exam carries.
  • Content covers air distribution systems for supply, return and exhaust in air conditioning and non-air-conditioning systems, plus chimneys, flues, venting and exhaust duct systems in residential and commercial work using metal duct, flexible duct, underground duct and fiberglass duct board.
  • The bulletin sends you to LARA's Mechanical Contractor Licensing Exam Reference Materials list (rev. 8/1/2024) for what you may bring. Reference books must be bound and unmarked.
  • If you fail you may retest an unlimited number of times within the year, paying the fee each attempt.
  • The Department (LARA BCC) must approve your application first. It sends a notification letter with instructions to pay and schedule with PSI; only the State decides eligibility.
  • PSI may add up to ten unscored experimental questions; they are not counted in your score and don't take time from the exam.
  • Cancel or reschedule at least 2 days before the appointment to keep your fee; late cancellations and no-shows forfeit it.

Frequently asked questions

What's on the Michigan ductwork exam?

55 questions on installing supply, return and exhaust air distribution systems, chimneys, flues and vents, duct materials and codes and standards, plus 2016 PA 407 and 1972 PA 230.

How much does it cost?

$50 to PSI per attempt. LARA application and license fees are separate.

Do I need Manual J and SMACNA?

They are on LARA's reference list for this exam. Check the list for what you may bring; our questions use the Michigan Mechanical Code and general practice where SMACNA text is not available to us.

Free questions with answers

Show all 10 free questions and answers
  1. In a dwelling unit where the kitchen and living area are one open room and the cooking appliance is electric, what is the minimum distance from the appliance to a return air intake opening under the Michigan Mechanical Code?

    Answer: 5 feet in any direction from the cooking appliance

    Section 601.5 normally bars return air from a kitchen. One exception covers a dwelling-unit kitchen that shares a single room with the living space where the cooking appliance is electric and the intake is not less than 5 feet in any direction from it. The 10-foot figure applies to the other kitchen exception, where the return serves only the kitchen.

    Reference: 2021 Michigan Mechanical Code, Section 601.5, Exceptions

  2. A contractor proposes to connect the return side of a forced-air furnace directly to a crawl space so the crawl space serves as the return. What does Section 601.5 say about this?

    Answer: A direct connection to the furnace return is not allowed, although transfer openings in the crawl space enclosure are not prohibited

    Section 601.5 says taking return air from a crawl space shall not be done through a direct connection to the return side of a forced-air furnace. It also says transfer openings in the crawl space enclosure are not prohibited. Moisture barriers, filters and clearance do not change the rule.

    Reference: 2021 Michigan Mechanical Code, Section 601.5

  3. A designer wants to form a return air shaft from gypsum board. Which condition does Section 603.5.1 place on this use?

    Answer: It is limited to return air systems with air at no more than 125 degrees F and a surface above the dew point

    Section 603.5.1 limits gypsum board air shafts to return air systems where air temperatures do not exceed 125 degrees F and the board surface is kept above the airstream dew point. Gypsum supply ducts may not be used in systems with direct evaporative cooling.

    Reference: 2021 Michigan Mechanical Code, Section 603.5.1

  4. A contractor proposes to run a clothes dryer exhaust and a bathroom exhaust fan into one shared duct to save a roof penetration. What does Section 501.2 say about this?

    Answer: It is not allowed, because dryer exhaust must be independent of all other systems

    Section 501.2 says dryer, domestic kitchen and hazardous exhaust shall be independent of all other systems. Single or combined environmental air exhaust systems must be independent of other exhaust systems, but dryer exhaust is specifically named as independent of all other systems.

    Reference: 2021 Michigan Mechanical Code, Section 501.2

  5. What rules apply to the transition duct that connects a dryer to the exhaust duct system under Section 504.9.3?

    Answer: A single listed length (UL 2158A) of no more than 8 feet that is not concealed within construction

    Section 504.9.3 requires dryer transition ducts to be a single length listed and labeled to UL 2158A, not greater than 8 feet long, and not concealed within construction.

    Reference: 2021 Michigan Mechanical Code, Section 504.9.3

  6. What is the minimum size of a chimney or vent serving a single appliance, other than an engineered system, under Section 801.6?

    Answer: An area equal to the area of the appliance connection

    Section 801.6 sets the minimum area of the chimney or vent serving a single appliance equal to the area of the appliance connection, except as otherwise provided in the chapter and except engineered systems.

    Reference: 2021 Michigan Mechanical Code, Section 801.6

  7. Two appliances on different floors of a house share a common vent. What does Section 801.19 say about this arrangement?

    Answer: Common venting of appliances on more than one floor level is prohibited, except for appliances in spaces accessed only from outdoors

    Section 801.19 prohibits common venting systems for appliances located on more than one floor level, except where all the appliances are in rooms or spaces accessed only from the outdoors and the enclosures do not communicate with occupiable areas of the building.

    Reference: 2021 Michigan Mechanical Code, Section 801.19

  8. How does the Skilled Trades Regulation Act define the ductwork classification for a mechanical contractor license in MCL 339.5801?

    Answer: The air distribution arrangement for supply, return and exhaust, including flues, vents and chimneys

    MCL 339.5801 defines ductwork as the air distribution arrangement for supply, return and exhaust in air conditioning systems and in nonair conditioning systems, with the materials and methods specified in the Michigan mechanical code or an equivalent model code. The definition states that ductwork includes flues, vents and chimneys.

    Reference: Skilled Trades Regulation Act, 2016 PA 407, MCL 339.5801(d)

  9. A duct will pass through a 2x10 floor joist, which has an actual depth of 9-1/4 inches. Under Section 302.3.1, what is the largest diameter of hole that may be bored in the joist, and where may it be located?

    Answer: About 3 inches, not within 2 inches of the top or bottom of the joist

    Section 302.3.1 limits the diameter of holes bored in joists to one-third of the joist depth, and holes may not be within 2 inches of the top or bottom. One-third of 9.25 inches is 3.08 inches, so about 3 inches. One-half of the depth would give 4.6 inches, which is too large.

    Reference: 2021 Michigan Mechanical Code, Section 302.3.1

  10. Which standard does Section 806.1 name for the construction and installation of metal chimneys?

    Answer: NFPA 211

    Section 806.1 says metal chimneys shall be constructed and installed in accordance with NFPA 211. NFPA 31 is named in Section 801.2.1 for oil-fired appliance venting, and NFPA 82 appears in Section 601.1 for ducts that discharge combustible material into a combustion chamber.

    Reference: 2021 Michigan Mechanical Code, Section 806.1