Requirements at a glance
| Agency | Board of State Examiners of Electricians (Division of Occupational Licensure); exams by PSI |
|---|---|
| License | Systems Technician |
| Format | Part 1: 60 questions, 120 minutes, open book, 70% to pass |
| Exams | Part 1 (60 questions, 120 minutes), then Part 2 Applied (30 questions, 60 minutes) |
| Fees | $80 to PSI for Part 1 and $55 for Part 2, plus the Board application and license fee |
Applicants for a Massachusetts Systems Technician license from the Board of State Examiners of Electricians.
Official links
How to get licensed, step by step
Apply to the Board
Apply through the Board with your education and work hours, a CORI authorization and a 15-hour code update certificate. Review takes up to 30 days. Approval lasts 12 months.
Board of State Examiners of Electricians (opens in a new tab)
Schedule the systems technician exam with PSI
PSI emails an exam confirmation notice after approval. Test at a PSI site in Auburn, Boston, Fall River, Lawrence or West Springfield. Cancel at least 2 days ahead.
Schedule with PSI (Massachusetts electricians) (opens in a new tab)
Pass both parts
Each part is scored separately at 70%. If you fail one, retake only that part, up to 6 times within a year of approval.
Schedule with PSI (Massachusetts electricians) (opens in a new tab)
Get licensed
Your scores go to the Division of Occupational Licensure. Pay the license fee in the eLIPSE portal to get your license.
Board of State Examiners of Electricians (opens in a new tab)
How to prepare
- Massachusetts adopted the 2026 NEC with state amendments (527 CMR 12.00) effective 4/24/2026. The PSI bulletin names no NEC year and adds code items about seven months after adoption, so check the bulletin for your test date.
- Bring the NEC, the Massachusetts amendments and NFPA 72. Highlighting, underlining and margin notes are allowed before the exam; only a silent, non-programmable calculator is allowed.
- Fire detection and notification (30) and NEC alarm requirements (20) are 50 of 60 Part 1 questions: tab NEC Articles 760 and 725 and the NFPA 72 chapters on initiating devices and notification.
- Security system installers also need a Security Clearance Certificate (S-License), per the PSI bulletin.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), edition adopted by the BoardEssential
Allowed in the exam room. Massachusetts adopted the 2026 edition with state amendments effective 4/24/2026; confirm the tested edition in your PSI bulletin.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
NFPA 72: National Fire Alarm and Signaling Code
Allowed in the exam room. Alarm systems are 6 questions on each electrician Part 1, and it is the core reference for the systems exams.
527 CMR 12.00: Massachusetts Electrical Code (state amendments to the NEC)
Allowed in the exam room. The Massachusetts amendments to the NEC.
237 CMR: Rules and Regulations of the Board of State Examiners of Electricians
Allowed in the exam room. Source of the licensing and state-specific questions.
Massachusetts regulations (Cornell LII, free to read) (opens in a new tab)
MGL Chapter 141: Supervision of Electricians
Allowed in the exam room. Licensing law behind the electrician questions.
Massachusetts General Laws (free to read) (opens in a new tab)
Official reference list (as published by the testing agency)
- National Electrical Code (NFPA 70), the edition adopted by the Board
- NFPA 72 National Fire Alarm and Signaling Code
- 527 CMR 12.00: Massachusetts amendments to the NEC (Part 2)
- 237 CMR 12.00 to 23.00 and MGL Chapter 141 (Part 2)
- Fire Alarm Signaling Systems Handbook, Certified Alarm Technicians Manual and Understanding and Servicing Alarm Systems (listed by PSI as sources, not allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| NEC Alarm Requirements | 20 | |
| Fire Detection and Notification | 30 | |
| General Elec Knowledge and Elec Theory | 10 | |
| Circuit Calculations (Ohm's Law) | 6 | |
| Electrical Schematics and Plans | 5 | |
| Materials and Components | 7 | |
| Troubleshooting and Testing | 8 | |
| Licensing Laws and Regulations | 4 |
Exam day details
- Administered by PSI Services for the Massachusetts Board of State Examiners of Electricians.
- Fee: $80 to PSI for Part 1 and $55 for Part 2. Board application and license fees are separate.
- Our practice exam combines the two parts: Part 1 is 60 questions in 120 minutes (NEC alarm requirements 20, fire detection and notification 30, general electrical knowledge and theory 10); Part 2 Applied is 30 questions in 60 minutes (circuit calculations 6, schematics 5, materials 7, troubleshooting 8, licensing laws 4). Each part needs 70% (42 and 21).
- Open book and two parts. Each part is scored on its own and you must pass both. Journeyman Part 2 is the Applied exam; Master Part 2 is Business and Law.
- If you fail a part, you can retake just that part up to 6 times within 1 year of your application approval date. Application approval lasts 12 months. Under 237 CMR 14.02 (amended 11/21/2025), after 3 failed attempts the Board requires proof of a Board-approved exam review or prep course, and after 6 you must repeat the required education hours.
- Allowed in the exam room: the adopted NEC, the Massachusetts amendments (527 CMR 12.00), NFPA 72, the Board's rules (237 CMR) and the listed Massachusetts laws. Highlighting and underlining are allowed, and so are handwritten notes in the margins before the exam; only a silent, non-programmable calculator is allowed.
- Exams are scheduled daily at PSI sites in Auburn, Boston, Fall River, Lawrence and West Springfield. Cancel at least 2 days ahead or you forfeit the fee.
- The Board approves your application first (high school diploma, 600 hours of journeyman education, 4 years and 8,000 hours of work, a CORI check and a 15-hour code update certificate; masters need a 150-hour master course and 1 year as a Massachusetts journeyman). Applications take up to 30 days.
- Security system installers also need a Security Clearance Certificate (S-License), per the PSI bulletin.
Note: 527 CMR 12.00 adopted the 2026 NEC with Massachusetts amendments, effective 4/24/2026. The PSI bulletin (effective 9/30/2026) names no NEC year, but says new code items can be added seven months after a code takes effect, which is about late November 2026. Our questions follow the 2026 NEC; check your PSI bulletin for the edition on your test date.
Frequently asked questions
What is on the Systems Technician exam?
Part 1 has 60 questions (NEC alarm requirements 20, fire detection and notification 30, general electrical knowledge and theory 10); Part 2 Applied has 30 questions on circuit calculations, schematics, materials, troubleshooting and licensing laws.
Is it open book?
Yes. Allowed references are the NEC and NFPA 72 for Part 1, plus 527 CMR 12.00, 237 CMR and MGL Chapter 141 for Part 2.
Which NFPA 72 edition is tested?
The PSI bulletin names no edition; our questions keep NFPA 72 items edition-neutral.
Free questions with answers
Show all 10 free questions and answers
A new fire alarm control panel (FACP) is being installed in an electrical room. Under the 2026 NEC, where must the listed surge-protective device for the panel's supply be placed?
Answer: On the supply side of the FACP, as close to the panel as practicable
Section 760.33 requires a listed SPD on the supply side of a fire alarm control panel, installed in accordance with Article 242, Part II. The 2026 text adds that the SPD be as close to the panel as is practicable. Devices on the load side or at the detectors do not protect the panel's power supply.
Reference: NFPA 70, National Electrical Code, 2026 edition, 760.33
What is the maximum overcurrent protection for 18 AWG conductors of a non-power-limited fire alarm (NPLFA) circuit, per 760.43?
Answer: 7 amperes
760.43 limits overcurrent protection to 7 amperes for 18 AWG and 10 amperes for 16 AWG NPLFA conductors. Conductors 14 AWG and larger are protected at their ampacity without applying the adjustment and correction factors of 310.14. The 10-ampere figure belongs to 16 AWG, not 18 AWG.
Reference: NFPA 70, National Electrical Code, 2026 edition, 760.43
Spot-type smoke detectors with a nominal 30 ft spacing are laid out on a smooth, level ceiling. Using the 0.7 rule for detector location, what is the greatest distance allowed from any point on the ceiling to the nearest detector?
Answer: 21 ft, found from 0.7 x 30 ft
On smooth ceilings every point must be within 0.7 times the nominal spacing of a detector, so 0.7 x 30 ft = 21 ft. The 0.5 factor is used for heat detector spacing from walls, and 30 ft is the spacing between detectors, not the maximum reach. The 0.7 factor is the radius of the square's circumscribed coverage circle.
Reference: NFPA 72, National Fire Alarm and Signaling Code, Chapter 17, spot-type smoke detector spacing on smooth ceilings (17.7.3.2.3.5 in the 2010 edition; 17.7.4.2.3.1 in 2025)
Spot-type heat detectors with a listed spacing of 40 ft are being placed on a smooth ceiling. What is the maximum distance allowed between a wall and the nearest detector?
Answer: 20 ft, which is one-half of the listed spacing
For spot-type heat detectors on a smooth ceiling, the distance from any wall or partition to the nearest detector is not more than one-half the listed spacing, here 20 ft. The 0.7 factor is the smoke detector rule and gives a different number. Listed spacing is measured between detectors, not from a wall.
Reference: NFPA 72, National Fire Alarm and Signaling Code, 17.6.3.1.1, heat detector spacing on smooth ceilings
A 24-volt ac transformer secondary is checked with a true-RMS meter and reads 24 volts. What is the approximate peak voltage of that sine wave, using peak = 1.414 x RMS?
Answer: About 33.9 volts
The peak of a sine wave is 1.414 times the RMS value: 24 x 1.414 = 33.9 V. Dividing by 1.414 gives 17.0 V, which is the RMS of a 24 V peak wave. Twice the RMS (48 V) is not the peak, and the meter's reading itself is the RMS, not the peak.
Reference: Basic electrical theory (Ohm's Law, power and circuit rules), Electrical theory: ac waveforms (RMS and peak)
A 24-volt supervised initiating circuit has a 4,700-ohm end-of-line resistor and no devices in alarm. Using Ohm's Law, what supervisory current flows (neglecting wire resistance)?
Answer: About 5.1 milliamperes
I = V / R = 24 V / 4,700 ohm = 0.00511 A, or about 5.1 mA. A result of 195.8 comes from dividing 4,700 by 24, and 112.8 multiplies instead of dividing. The calculation also ignores wire resistance, which is very small compared with 4,700 ohms.
Reference: Basic electrical theory (Ohm's Law, power and circuit rules), Ohm's Law (I = V / R)
A fire alarm floor plan is drawn at 1/8 in. = 1 ft. A cable run measures 3.5 in. on the plan. What is its actual horizontal length?
Answer: 28 ft, since 3.5 in. x 8 ft per inch = 28 ft
At 1/8 in. = 1 ft each inch on the drawing equals 8 ft, so 3.5 x 8 = 28 ft. Using 4 ft per inch is the 1/4 in. scale, using 12 mixes inches and feet, and dividing by 8 is the inverse operation. This is a horizontal length only; vertical drops are added from the elevation or riser information.
Reference: Trade reference: reading electrical drawings, Reading electrical drawings: architectural scale
Which item should NOT be printed on the jacket of a listed Class 2, Class 3 or power-limited fire alarm cable under the 2026 cable marking rules?
Answer: A voltage rating, which could suggest suitability for light and power use
The cable marking rules say voltage ratings shall not be marked on these cables (unless the cable has multiple listings that require it), because a voltage marking could be misread as making the cable suitable for Class 1, light or power circuits. The AWG size, the manufacturer identification and a temperature rating above 60 degrees C are required markings.
Reference: NFPA 70, National Electrical Code, 2026 edition, 722.100(A) (cable marking requirements, item 7)
With all strobes in alarm, a technician measures 24.0 volts at the panel but only 17.8 volts at the last strobe on a notification circuit, whose appliances need a minimum of 16 volts. What does the reading show?
Answer: The drop is 6.2 V, and 17.8 V is above the 16 V minimum, so it is acceptable
Voltage drop is the difference between the source and the end of line: 24.0 - 17.8 = 6.2 V. The test is whether the voltage at the last appliance stays at or above the appliance's minimum operating voltage (16 V here), so 17.8 V is acceptable, although there is little margin left. Adding the readings is meaningless.
Reference: Trade reference: voltage drop calculations (Ohm's Law), Voltage drop at end of line
How many clock hours of systems work experience, and over what minimum period, must an apprentice document before applying for the Systems Technician exam under 237 CMR 13.04(a)?
Answer: 4,000 hours in no less than two years
237 CMR 13.04(a) requires documentary proof of at least 4,000 clock hours of systems work experience in no less than two years, under the direct supervision of a Massachusetts Systems Technician or Journeyman. The 8,000-hour, four-year figures belong to the Journeyman license, and 2,000 hours is the maximum credit for electrical work experience.
Reference: 237 CMR (Board of State Examiners of Electricians), 237 CMR 13.04(a)
Sources
- PSI: Massachusetts Electricians Candidate Information Bulletin (effective 9/30/2026) (opens in a new tab)
- Massachusetts Board of State Examiners of Electricians (opens in a new tab)
Questions last verified November 15, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.