Requirements at a glance
| Agency | Board of State Examiners of Electricians (Division of Occupational Licensure); exams by PSI |
|---|---|
| License | Journeyman Electrician (Part 2) |
| Format | Part 2: 30 questions, 60 minutes, open book, 70% to pass |
| Exams | Part 2 Applied (30 questions, 60 minutes) |
| Fees | $80 to PSI for Part 1 and $55 for Part 2, plus the Board application and license fee |
Electrical apprentices applying for a Massachusetts journeyman electrician license who have passed, or are about to take, Part 1.
Official links
How to get licensed, step by step
Apply to the Board
Apply through the Board with your education and work hours, a CORI authorization and a 15-hour code update certificate. Review takes up to 30 days. Approval lasts 12 months.
Board of State Examiners of Electricians (opens in a new tab)
Schedule the journeyman electrician Applied exam with PSI
PSI emails an exam confirmation notice after approval. Test at a PSI site in Auburn, Boston, Fall River, Lawrence or West Springfield. Cancel at least 2 days ahead.
Schedule with PSI (Massachusetts electricians) (opens in a new tab)
Pass both parts
Each part is scored separately at 70%. If you fail one, retake only that part, up to 6 times within a year of approval.
Schedule with PSI (Massachusetts electricians) (opens in a new tab)
Get licensed
Your scores go to the Division of Occupational Licensure. Pay the license fee in the eLIPSE portal to get your license.
Board of State Examiners of Electricians (opens in a new tab)
How to prepare
- Massachusetts adopted the 2026 NEC with state amendments (527 CMR 12.00) effective 4/24/2026. The PSI bulletin names no NEC year and adds code items about seven months after adoption, so check the bulletin for your test date.
- Bring the NEC, the Massachusetts amendments and NFPA 72. Highlighting, underlining and margin notes are allowed before the exam; only a silent, non-programmable calculator is allowed.
- Troubleshooting and testing (6), circuit calculations (5), schematics (5), materials (5), Massachusetts amendments (5) and licensing laws (4): bring 527 CMR 12.00 and 237 CMR.
- Start with the free questions above to find your weak topics, then drill those first.
- Take at least two full timed simulations before exam day. Timing is where most people fail open-book exams.
- Read every explanation, including for questions you got right, and look the section up in your own book.
Books for this exam
This is an open-book exam: you can bring the references below, and most questions come from the NEC. Tabs and highlighting are allowed. Free online copies are read-only and can't be used in the exam room.
NFPA 70: National Electrical Code (NEC), edition adopted by the BoardEssential
Allowed in the exam room. Massachusetts adopted the 2026 edition with state amendments effective 4/24/2026; confirm the tested edition in your PSI bulletin.
NFPA store (opens in a new tab)Free online access (opens in a new tab)
527 CMR 12.00: Massachusetts Electrical Code (state amendments to the NEC)
Allowed in the exam room. The Massachusetts amendments to the NEC.
237 CMR: Rules and Regulations of the Board of State Examiners of Electricians
Allowed in the exam room. Source of the licensing and state-specific questions.
Massachusetts regulations (Cornell LII, free to read) (opens in a new tab)
MGL Chapter 141: Supervision of Electricians
Allowed in the exam room. Licensing law behind the electrician questions.
Massachusetts General Laws (free to read) (opens in a new tab)
Official reference list (as published by the testing agency)
- National Electrical Code (NFPA 70), the edition adopted by the Board
- 527 CMR 12.00: Massachusetts amendments to the NEC
- 237 CMR 12.00 to 23.00: Rules and Regulations of the Board of State Examiners of Electricians
- MGL Chapter 141: Supervision of Electricians
- Ugly's Electrical References and American Electricians' Handbook (listed by PSI as sources, not allowed in the exam room)
What's on the exam
Official content outline from PSI Services (number of questions per topic):
| Topic | Questions | |
|---|---|---|
| Circuit Calculations (Ohm's Law) | 5 | |
| Electrical Schematics and Plans | 5 | |
| Materials and Components | 5 | |
| Troubleshooting and Testing | 6 | |
| Massachusetts Amendments | 5 | |
| Licensing Laws and Regulations | 4 |
Exam day details
- Administered by PSI Services for the Massachusetts Board of State Examiners of Electricians.
- Fee: $55 to PSI for Part 2. Board application and license fees are separate.
- 30 questions in 60 minutes; 70% (21) to pass. This is Part 2 for journeymen; Part 1 (80 questions) is a separate practice exam.
- Open book and two parts. Each part is scored on its own and you must pass both. Journeyman Part 2 is the Applied exam; Master Part 2 is Business and Law.
- If you fail a part, you can retake just that part up to 6 times within 1 year of your application approval date. Application approval lasts 12 months. Under 237 CMR 14.02 (amended 11/21/2025), after 3 failed attempts the Board requires proof of a Board-approved exam review or prep course, and after 6 you must repeat the required education hours.
- Allowed in the exam room: the adopted NEC, the Massachusetts amendments (527 CMR 12.00), NFPA 72, the Board's rules (237 CMR) and the listed Massachusetts laws. Highlighting and underlining are allowed, and so are handwritten notes in the margins before the exam; only a silent, non-programmable calculator is allowed.
- Exams are scheduled daily at PSI sites in Auburn, Boston, Fall River, Lawrence and West Springfield. Cancel at least 2 days ahead or you forfeit the fee.
- The Board approves your application first (high school diploma, 600 hours of journeyman education, 4 years and 8,000 hours of work, a CORI check and a 15-hour code update certificate; masters need a 150-hour master course and 1 year as a Massachusetts journeyman). Applications take up to 30 days.
Note: 527 CMR 12.00 adopted the 2026 NEC with Massachusetts amendments, effective 4/24/2026. The PSI bulletin (effective 9/30/2026) names no NEC year, but says new code items can be added seven months after a code takes effect, which is about late November 2026. Our questions follow the 2026 NEC; check your PSI bulletin for the edition on your test date.
Frequently asked questions
What is the Applied exam?
Part 2 of the journeyman electrician exam: 30 questions on circuit calculations (5), schematics and plans (5), materials and components (5), troubleshooting and testing (6), Massachusetts amendments (5) and licensing laws (4).
Do master electricians take it?
No. Master electricians take Part 2 Business and Law instead.
Which NEC edition applies?
Massachusetts adopted the 2026 NEC with state amendments effective 4/24/2026. The PSI bulletin names no year, so check it for your test date.
Free questions with answers
Show all 10 free questions and answers
A single-phase 240-volt resistive water heater is rated 7,500 watts. What current does it draw at rated voltage?
Answer: 31.25 A
Current equals power divided by voltage: I = P / E = 7,500 W / 240 V = 31.25 A. Dividing by 120 V gives 62.5 A (wrong voltage); 7,500 / 208 = 36.06 A and 7,500 / (1.732 x 240) = 18.04 A (three-phase formula) do not apply to a single-phase 240-volt load.
Reference: Ohm's law and power relationships (basic electrical theory), I = P / E
A 230-volt single-phase, 32-ampere load is 200 ft from its panel (one way). The voltage drop must not exceed 3 percent. What is the smallest copper conductor that meets this limit? (K = 12.9; circular mils: 10 AWG 10,380; 8 AWG 16,510; 6 AWG 26,240; 4 AWG 41,740.)
Answer: 6 AWG
The allowed drop is 0.03 x 230 = 6.9 V. Required circular mils = 2 x 12.9 x 32 x 200 / 6.9 = 23,930 CM, so the next larger standard size is 6 AWG (26,240 CM). 8 AWG (16,510 CM) would drop 10.0 V, about 4.3 percent, and 10 AWG would drop 15.9 V. 4 AWG works but is larger than necessary. Ampacity alone would suggest 10 AWG or 8 AWG, which is why the voltage-drop check matters.
Reference: Voltage-drop formula with NEC Chapter 9, Table 8, Chapter 9 Table 8; VD = 2KIL / CM
A hallway light must be controlled from three locations. Which switch combination is used, and where does the extra switch go?
Answer: Two 3-way switches at the ends and one 4-way switch connected between the two traveler pairs
Control from three places uses a 3-way switch at each end and a 4-way (double-pole, double-throw, crossover) switch in the middle. The two travelers from the first 3-way go to the 4-way input terminals, and the other pair of terminals on the 4-way goes on to the second 3-way. Single-pole and 4-way switches at the ends cannot give three-point control, and switches do not belong in the neutral.
Reference: Electrical plan reading and diagram practice, Three-way and four-way switch circuits
On a ladder diagram for a three-wire start-stop motor control circuit, the holding (seal-in) contact of the motor starter is connected how?
Answer: A normally open auxiliary contact wired in parallel with the START pushbutton
When the START button is pressed the coil energizes and the starter's normally open auxiliary contact closes. Because that contact is in parallel with START, it keeps the coil energized after the button is released. A contact in series with the START button, or a normally closed contact, would not seal the circuit in. The STOP button is separate, normally closed, and in series with the coil.
Reference: Electrical plan reading and diagram practice, Ladder (elementary) diagram, three-wire control
A box fill calculation comes to 22.5 cubic inches. Which of these metal boxes is the smallest that meets the requirement? (Use Table 314.16(A).)
Answer: 4 in. square, 2-1/8 in. deep
Table 314.16(A) gives 18.0 in3 for a 4 x 1-1/4 square box, 21.0 in3 for a 4 x 1-1/2 square box, 21.5 in3 for a 4 x 2-1/8 round/octagonal box and 30.3 in3 for a 4 x 2-1/8 square box. Only the 4 x 2-1/8 square box exceeds the required 22.5 in3.
Reference: National Electrical Code (NFPA 70), 2026 edition, Table 314.16(A)
A 18-in. long EMT nipple between two cabinets is 1/2 in. trade size (total area 0.304 in2). Using the Chapter 9 provision for conduit nipples not over 24 in., what is the largest number of 12 AWG THHN conductors (0.0133 in2 each) allowed in the nipple?
Answer: 13
A nipple of 24 in. or less between enclosures may be filled to 60 percent: 0.304 x 0.60 = 0.1824 in2. 0.1824 / 0.0133 = 13.7, so 13 conductors (13 x 0.0133 = 0.1729 in2; 14 would be 0.1862 in2, which is over). 9 conductors is the answer from the normal 40 percent limit (0.122 / 0.0133), 14 rounds up, and 22 is a 100 percent fill.
Reference: National Electrical Code (NFPA 70), 2026 edition, Chapter 9, Table 1, Note 4; Table 4; Table 5
A 120/240-volt single-phase multiwire circuit has a 10-ohm load on one leg and a 30-ohm load on the other. The shared neutral opens at a loose splice. What voltage appears across the 30-ohm load?
Answer: 180 V
With the neutral open, the two loads are in series across 240 V. Total resistance is 10 + 30 = 40 ohms, current is 240 / 40 = 6 A, and the drop across the 30-ohm load is 6 x 30 = 180 V (60 V across the 10-ohm load). That overvoltage is why an open shared neutral burns out lighter loads. 120 V is the normal value and 240 V would need the other load to be absent.
Reference: Troubleshooting and testing practice (trade knowledge), Open neutral on multiwire circuits
A GFCI receptacle holds its reset when its downstream LOAD wires are disconnected, but trips as soon as those wires are reconnected. Where is the most likely fault?
Answer: A ground fault or neutral-to-ground contact in the downstream wiring or devices
The GFCI itself works when it is isolated from the downstream circuit, so the leakage is on the LOAD side: a neutral touching ground, a ground fault in a downstream box or device, or a shared neutral from another circuit. A defective device would trip even with the load disconnected, and an overloaded breaker would trip the breaker, not the GFCI.
Reference: Troubleshooting and testing practice (trade knowledge), GFCI troubleshooting
A pool contractor in Massachusetts proposes rigid metal conduit made of red brass, a nonferrous metal other than aluminum, for a corrosive pool equipment room. What does the Massachusetts exception added to 344.2 provide?
Answer: Rigid metal conduit of nonferrous metals other than aluminum may be approved by the authority having jurisdiction
The Massachusetts exception to 344.2 says rigid metal conduit made from nonferrous metals other than aluminum is permitted to be approved, so the authority having jurisdiction may accept it. It is not automatically accepted, it is not limited to underwater luminaire wiring, and the exception exists precisely because steel and aluminum are not the only possible materials.
Reference: 527 CMR 12.00 (2026 Massachusetts Electrical Code amendments), 344.2 (Massachusetts exception)
A Massachusetts journeyman electrician has passed the master electrician examination. Under M.G.L. c. 141, section 3, what else must be true before certificate A is issued to that person's business?
Answer: The person has held a certificate B (journeyman) license for at least twelve months
Section 3(1) of c. 141 issues certificate A to a person, firm or corporation when the person (or a member or officer) has passed the master examination and has held a certificate B for at least twelve months. The certificate D requirement applies to certificate C (systems contractor), and continuing education is a renewal requirement.
Reference: M.G.L. c. 141 (Supervision of Electricians), Section 3(1)
Sources
- PSI: Massachusetts Electricians Candidate Information Bulletin (effective 9/30/2026) (opens in a new tab)
- Massachusetts Board of State Examiners of Electricians (opens in a new tab)
Questions last verified November 15, 2026. Licensing rules change. Always confirm current requirements with the licensing agency before you apply.